6.  Programming  the  Unit  in  Stand-Alone

 

Mode. (Power Up Settings)

 

N.B.  to  change  any  settings  on  the  receiver  unit,  the 
receiver  needs  to  be  powered  down,  the  settings 
changed and then powered up again.

 

 

Restoring  the  Factory  Default  Settings:

 

1.  Remove  power  from  the  unit  by  removing  jumper 

J5  and switch  all  Dip switches  OFF. 

2.  Switch Dip switches 1, 5, 6, 7 and 8  ON 
3.  Restore  Power  to  the  Unit  by  replacing  J5 
4.  Switch  Dip Switch  8  OFF 
5.  Wait  for  the  LED’s  to  start  flashing  alternately. 
6.  Switch  ALL  Dip  switches  OFF. 
7.  When  the  LED’s  stop  flashing  the  unit  is  in  the 

normal  operating  mode 

 

The  factory  default  settings  with  all  Dip  switches

 

OFF and all jumpers ON are as follow: 

Three  Minute  Retrigger  Protect 

Off 

Remote  Learn 

Off 

Panic  Remote  Learn 

Off 

RF  Device  Learn 

Off 

Ambient  Noise  Level  Test 

Off 

Device  Failure  Relay 

Disabled 

Panic  Relay 

Enabled 

3  Sec  Remote  Panic 

Enabled 

Relays 

Pulse 

Relay  4  Output 

Selected 

Power  Jumper 

On 

Relay  Pulse  Period 

3 Sec 

Relays  Safe  /  Secure 

Secure 

Panic  Relay 

Relay  4 

Device  Failure  Relay 

Relay  3 

RF  Device  Output  Relay 

None 

Remote  Button  Outputs 

Button  1 

Relay  1 

Button  2 

Relay  2 

Button  3 

Relay  3 

Button  4 

Relay  4 

Arm  /  Disarm  Button 

Button  1 

Stay Arm Button 

Button  2 

Instant  Panic  Button 

None 

3  Sec  Hold for  Panic  Button 

All 

Relay  3  Min  Retrigger  Protect 

None 

Signal  Jamming  Detect  Period 

30s 

Device  Not  Reporting 

1hr  max 

 

Deleting  ALL  the  User  Remotes:

 

1.  Remove  power  from  the  unit  by  removing  jumper 

J5  and switch  all  Dip switches  OFF. 

2.  Switch Dip switches 2, 5, 6, 7 and 8  ON 
3.  Restore  Power  to  the  Unit  by  replacing  J5 
4.  Switch  Dip Switch  8  OFF 
5.  Wait for  the  LED’s to  start alternating 
6.  Switch  ALL  Dip  switches  OFF. 
7.  When  the  LED’s  stop  flashing  the  unit  is  in  the 

normal  operating  mode 

 

Deleting  ALL  Supervised  RF  Devices

 

(e.g.  RF  Passive  IR’s):

 

1.  Remove  power  from  the  unit  by  removing  jumper 

J5  and switch  all  Dip switches  OFF. 

2.  Switch Dip switches 3, 5, 6, 7 and 8  ON 
3.  Restore  Power  to  the  Unit  by  replacing  J5 
4.  Switch  Dip Switch  8  OFF 
5.  Wait  for  the  LED’s  to  start  flashing  alternately. 
6.  Switch  ALL  Dip  switches  OFF. 
7.  When  the  LED’s  stop  flashing  the  unit  is  in  the 

normal  operating  mode 

 

Adjusting  the  Relay  Pulse  Periods:

 

1.  Remove  power  from  the  unit  by  removing  jumper 

J5  and switch  all  Dip switches  OFF. 

2.  Switch  Dip  switches  7  and  8  ON 
3.  Restore  Power  to  the  Unit  by  replacing  J5 
4.  To adjust relay 1’s pulse period, switch Dip switch 

1  ON.* 

5.  Wait  for  as  long  as  the  pulse  needs  to  be.  (Up  to 

10  minutes) 

6.  Switch  Dip  switch  1  OFF.  (For  relay  1’s  pulse 

period) 

7.  Switch  Dip switch  8  OFF. 
8.  Wait  for  the  LED’s  to  start  flashing  alternately. 
9.  Switch  ALL  Dip  switches  OFF. 
10.  When  the  LED’s  stop  flashing  the  unit  is  in  the 

normal  operating  mode 

 

Changing Between Relay Safe and Secure Modes:

 

1.  Remove  power  from  the  unit  by  removing  jumper 

J5  and switch  all  Dip switches  OFF. 

2.  Switch  Dip  switches  6  and  8  ON 
3.  Restore  Power  to  the  Unit  by  replacing  J5 
4.  To  make  Relay  2  and  4  Fail  Safe,  switch  Dip 

switches 2 and 4 ON.* (Any relay not selected will 
be  Fail  Secure.) 

5.  Switch  Dip switch  8  OFF. 
6.  Wait  for  the  LED’s  to  start  flashing  alternately. 
7.  Switch  ALL  Dip  switches  OFF. 
8.  When  the  LED’s  stop  flashing  the  unit  is  in  the 

normal  operating  mode 

 

Selecting the Panic Relay Output:

 

1.  Remove  power  from  the  unit  by  removing  jumper 

J5  and switch  all  Dip switches  OFF. 

2.  Switch  Dip switches  6,  7  and  8  ON 
3.  Restore  Power  to  the  Unit  by  replacing  J5 
4.  Select the relay to be the Panic Relay.* (If no relay 

is  selected,  the  panic  relay  will  be  disabled.) 

5.  Switch  Dip switch  8  OFF. 
6.  Wait  for  the  LED’s  to  start  flashing  alternately. 
7.  Switch  ALL  Dip  switches  OFF. 
8.  When  the  LED’s  stop  flashing  the  unit  is  in  the 

normal  operating  mode 

 

*  Where  indicated  Dip  switch  1  represents  Relay  1,  Dip 
switch  2  represents  Relay  2,  Dip  switch  3  represents  Relay

 

3  and  Dip  switch  4  represents  Relay  4.

 

IDS  700-284-3  JULY  2005  REV  B  VER  1.40

 

 