The product shall not be used for purposes or in ways other than
those for which the product is intended for and as described in
this manual. Incorrect uses can damage the product and cause
injuries and damages.
The company shall not be deemed responsible for the non-
compliance with a good manufacture technique of gates as
well as for any deformation, which might occur during use.
Keep this manual for further use. Qualified personnel, in com-
pliance with regulations in force, shall install the system.
packaging must be kept out of reach of children, as it can be
hazardous. For disposal, packaging must be divided the various
types of waste (e.g. carton board, polystyrene) in compliance
with regulations in force.
The installer must supply all information on the automatic,
WARNING
manual and emergency operation of the automatic system and
supply the end user with instructions for use.
An omnipolar switch/section switch with remo-
te contact opening equal to, or higher than 3mm
must be provided on the power supply mains.
Make sure that before wiring an adequate differential switch
and an overcurrent protection is provided.
pursuant to safety regulations in force, some types of instal-
lation require that the gate connection be earthed. During
installation, maintenance and repair, cut off power supply
before accessing to live parts.
Descriptions and figures in this manual are not binding.
While leaving the essential characteristics of the product
unchanged, the manufacturer reserves the right to modify
the same under the technical, design or commercial point
of view without necessarily update this manual.
WARNING
Before installing the automatic system read the instructions hereunder
carefully.
It is strictly forbidden to use the product VN.M for applications other
than indicated in this instruction handbook.
show the user how to use the automation system.
Give the user the part of the leaflet which contains the instructions for
users.
OpERATING LIMITs AND WARNINGs
This geared motor has been studied and manufactured to activate bal-
anced sectional doors (pOWER35).
Before proceeding to install the system, make sure that the door is bal-
anced and slides well. Check that the ropes, the springs and the para-
chuting system are in good conditions. For doors that have not been
installed recently, check also all the other parts subject to wear and tear.
The above instructions are essential for the safety of the system and the
reliability of the operator.
INsTALLATION
Thanks to its versatility, this geared motor can be assembled not only on
the right-side or left-side of the door, but also horizontally or vertically
(fig. 2). The geared motor has been designed to directly activate the ca-
ble winding shaft of the door which must feature 1" diameter (25.4mm)
and should be provided of housing for the key. For cable winding shafts
having a different diameter, an adapter should be provided (item VN.A30
for diam. 30 shafts, item VN.A3175 for diam. 31.75 shafts, item VN.A40
for diam. 40 shafts).To fit the unit proceed as follows:
• Make sure that the distance between the cable winding shaft and the
surface to which the bracket should be fitted ranges between 82 and
150mm (as per fig. 3).
• Weld or fit the bracket S with screws to the surface.
• Insert the feared motor in the cable winding shaft.
• Tighten the screws inserting the tightening key C first.
To calculate the movement speed of the door, proceed as follows:
V(door speed) = d(diam. of cable winding drum - m) x 3.14 x 24 = m/1'
It is possible to use the geared motor by extending the motion to the
rope winding-up shaft by means of a chain (item VN.RM). The motion
can possibly be transmitted reduced or multiplied (item VN.RV) (fig. 4).
To calculate the movement speed of the door, proceed as follows:
V(door speed) = d(diam. of cable winding drum - m) x 3.14 x 24 x Z1 /
Z2 = m/1'
ADJUsTMENT OF THE LIMIT sWITCHEs
The geared motor is equipped with 4 microswitches: 1 is the opening limit
switch (red cam), 1 the opening over-travel (blue cam), 1 closing limit
switch (yellow cam) and 1 is at disposal of the accessories (black cam),
N.C. max. 3A, 24Vac/dc max. To adjust the cams proceed as follows (fig.
10):
• Put a screwdriver in the hole F to avoid the rotation of the shaft.
• Loosen the nut D to allow rotation of the cam with a very reduced
resistance.
• Manually move the door until it is almost completely close and adjust
the yellow cam.
• Repeat the operation while opening the door and adjust the red cam.
• Then position the blue cam so that it is activated slightly delayed with
respect to the red cam.
• Power the automatic unit and operate it (if it is a closing operation, invert
wires 1 and 3 of the motor power supply, fig. 6 and 7) while adjusting the
closing cam (yellow) with slight adjustments as per fig. 11.
• Slightly tighten nut D.
Technical data
pOWER35
power supply
Consumption
power
Torque
* Door max. weight
Exit shaft hole
Max. force on Ø 120
Exit rounds
** L.s. reduction ratio
Jogging
Thermal switch trig.
Operat. temperature
Capacitor
Lubrication
Weight
Dimensions: see fig.1
1x230V (50Hz)
3A
600W
90Nm
3700N
25.4mm
1500N
24rpm
1/20
30%
130°C
-20°C / +50°C
20µF
Agip Blasia 32
15kg
* For balancing doors and diameter Ø 120mm of the steel cable wind-
ing drum.
** Max. no. of rounds from the exit shaft.
10