MSD-72 Series User’s Guide
98
9.12.1 Registering/editing control command
Menu Top
→
PRESET COMMAND
→
COMMAND EDIT
Setting for Each command
Setting value [Table 9.19] Setting items of control command
You can create and edit up to 32 control commands.
The setting of this menu is not updated until the MENU/SET key is pressed. Make sure to press the
MENU/SET key to update the setting.
[Table 9.19] Setting items of control command
Item
Setting
Description
Range
COM
CC
CEC
PORT
yes
yes
yes
Select “COM”, “CC” or “CEC”.
COM: Communication
command [Default]
CC: Contact closure
CEC: HDMI CEC control
COM SIZE
yes
no
no
Set the number of bytes to be sent
starting with the first byte.
0BYTE to 30BYTE
[Default]: 0BYTE
DELAY
yes
yes
yes
Set the waiting time of the control
command. Use this item for devices such
as projectors that requires time to cool
down after powering off.
0ms to 999s999ms
[Default] 0ms
Communication
port
yes
no
no
Set the following communication ports to
“OFF” (not sending communication
commands) or “ON” (sending
communication commands). Those ports
can be set separately, and
communication commands can be sent to
multiple communication ports at the same
time.
・
RS1: RS-232C CH1
*5
・
RS2: RS-232C CH2
*5
・
LOOP BACK: Internal loop back
・
LAN1 to LAN8: LAN connection 1 to 8
*6
OFF [Default]
ON
COMMAND
INPUT MODE
yes
no
no
Set the input mode of send command
data. Select “ASCII” if “DATA” of
“COMMAND” consists of only 0A, 0D, and
20 to 7D of ASCII codes. Select “HEX” if
“DATA” of “COMMAND” includes other
codes.
ASCII [Default]
HEX
Send command
data
yes
no
no
Set the command from the first byte
according to the number of bytes set in
“COM SIZE” (up to 30 bytes).
0A, 0D, 20 to 7D in ASCII,
00 to FF in hex
[Default]: 20 (space)