![IDK MSD-702UHD Скачать руководство пользователя страница 103](http://html1.mh-extra.com/html/idk/msd-702uhd/msd-702uhd_user-manual_3786615103.webp)
MSD-701UHD / 702UHD / 801UHD/ 802UHD User’s Guide
103
9.13.2 Registering / Editing reply command
Menu Top
→
PRESET COMMAND
→
RECV COMMAND EDIT
Setting for Each command
Setting value [Table 9.26] Setting items of return command
You can create and edit up to 32 reply commands.
The setting of this menu is not updated until the MENU/SET key is pressed. Make sure to press the
MENU/SET key to update the setting.
[Table 9.26] Setting items of return command
Item
Description
Range
SIZE
Set the number of bytes from the first byte to be
compared.
0 to 30 bytes
[Default] 0 byte
PROCESS
Select “STOP” (to stop the next operation),
“EXEC” (to execute it), or “RETRY” (to send the
command again) for when received data and
reply command data match.
STOP
EXEC [Default]
RETRY: Resend commands
PJLink
Select whether PJLink commands are set or not
for when input reply command data is input.
OFF [Default]
ON
COMMAND INPUT
MODE
Select the input mode of reply command data.
“ASCII”: For data consisting of only 0A, 0D, 20
to 7D (text)
“HEX”: For data including other codes
ASCII [Default]
HEX
DATA
Set the command to be compared with the
received data from the first byte to the byte
count set in “SIZE”. If using alphabets (A to Z, a
to z), make sure to distinguish capital and lower
case letters. (Up to 30 bytes)
0A, 0D, and 20 to 7D of ASCII
code or
00 to FF (Hex)
[Default] 20 (Space)
(Values described above all with
hex)
MASK
Received data is compared with MASK DATA
without “AND” of each bit and reply command
data. (Use this item to determine the state using
the received data bit. Settable if “COMMAND
INPUT MODE” is set to “HEX”; if “ASCII” is
selected, “FF” is set automatically.)
00 to FF (Hex)
[Default] All: “FF”
MEMO
Register a note up to 14 characters.
When reply command is received, the
registered note is displayed.
20 to 7D of ASCII code except
for 2C (,) [Default] All: Spaces
Those default values do not apply to reply commands 31 and 32.