MSD-62 Series User’s Guide
86
9.8.2 The total number of horizontal dots
Menu Top
→
INPUT TIMING
→
H TOTAL DOTS
Setting for Each input channel, each input signal, analog input only
Setting value 400DOT to 4125DOT [Default] varies depending on the input signal
You can set the total number of horizontal dots of analog RGB/analog YPbPr input video.
The settable values vary depending on the input signal. If interlace signal are input, the sampling clock
(Horizontal synchronized frequency x the total number of horizontal dots) must be within 13 MHz to 81 MHz.
If non-interlace signal are input, the sampling clock must be within 13 MHz to 162 MHz.
If other signals are input, the total number only can be displayed but not be set.
If there is no input signal on the input channel it shows “NOT AVAILABLE NOW” on the front VFD screen.
9.8.3 Start position
Menu Top
→
INPUT TIMING
→
H START (Horizontal) / V START (Vertical)
Setting for Each input channel, each input signal
Setting value [Table 9.8] Settings of start position
[Table 9.9] Settings of start position
Function
Setting value
Horizontal start position
64DOT to 2900DOT
(The total number of horizontal dots
-
Horizontal active area or less)
Vertical start position
10LINE to 2048LINE
(The total number of vertical lines
-
Vertical active area or less)
[Default] varies depending on the input signal.
You can set the horizontal/vertical starting position.
If the set value exceeds the limitation mentioned below the display start position will be set automatically
within the limitation.
Horizontal : The total number of horizontal dots > Horizontal active area > Horizontal starting position
Vertical : The total number of vertical lines > Vertical active area > Vertical starting position
If 4K video signals are input, only the display start position will be displayed; the value cannot be set.
If there is no input signal on the input channel it shows “NOT AVAILABLE NOW” on the front VFD screen.