HDC-S400/200 Users Guide
37
8.12 [ F28 ] Setting Dolby D Audio
You can set the maximum sampling frequency of Dolby Digital Plus Audio that is output from the source
device.
32: 32 kHz
44: 44.1 kHz
48: 48 kHz
oFF: OFF [Default]
Notes:
● Some LCD monitors do not support some audio formats. Select the audio format and sampling frequency
supported by your device.
● This is enabled only if one of 03 to 22 is selected for resolution setting of EDID.
・
Setting by menu
Normal condition (OFF)
↓ SET key
“
-
” “
+
” key set INPUT Dolby D Audio
→ select F28
↓ SET key
“
-
” “
+
” key set Dolby D Audio [Default: OFF]
OFF 32: 32 kHz 44: 44.1 kHz 48: 48 kHz
↓
During Dolby D Audio setting is processing, READY LED is OFF. After setting is
finished, the LED is ON
↓
After processing, 7-SEGMENT LED goes back to menu.