HDC-RH401/201/101 Users Guide
33
8.7 [ F16 ] Setting No-signal input monitoring time of Video signal
If you change EDID of the HDC or turn on/off the HDC, the source devices may not output video signals. In
this menu, you can set the monitoring time.
・
No-signal input monitoring time (OFF, 2 to 15 seconds [Default: 10 seconds])
[Fig. 8.5] No-signal input monitoring time
Notes:
● If you use the power saving or Dual monitor function of the PC (Source device), set this menu to “OFF”. When a PC is
requested to output video signals, the PC may cancel those functions.
● If you set the time that is shorter than the output timing, the source device repeats reprocessing of output video signals.
In this case, change the time to longer.
[Fig. 8.6] Repeating output signal setting
Changing
EDID
ON
OFF
Requesting the source devices
to output video signals
No-signal input
monitoring time
Hot plug
ON
OFF
Video signals
from source
device
Changing EDID
Monitoring time
ON
OFF
Outputting video from source device
Video signals from
source device
Monitoring time Monitoring time
Requesting the source devices to output video signals