Idis DR-2308P Скачать руководство пользователя страница 11

11

Basic Feature

Live Mode

Once Camera Registration is complete, the system will enter 
Live Mode. 
Press the 

MENU

 button on the remote control while in Live 

mode to bring up the Live menu on the top of the screen. 
Press 

MENU

 once more to hide the menu. Use the Arrow 

buttons on the front panel of the NVR or the remote control 
to select the menu options.

Video Recording

Records the live video.
Refer to the manual for more information.

Panic Recording

Select 

Live

 or 

Search

 menu's Panic Recording   icon or 

press the 

Panic Recording

 button on the front panel or 

the remote control to commence panic recording on all 
registered cameras.
To stop Panic Recording, select the Panic Recording   
icon or press the 

Panic Recording

 button again. If the 

Panic Recording Duration

 option under 

Record Setup 

> General

 has been configured, Panic Recording will 

automatically terminate after the specified duration of time 
has elapsed.

• 

Panic Recording takes place irrespective of any 
recording schedule set up by the user.

• 

Panic Recording video profile from

 Record Setup – 

General

 applies to all Panic Recording videos.

Panic Recording will not take place if recording mode 
is not set to 

Recycle

 and the HDD has reached 100% 

of its capacity.

Audio Recording

If the Record Audio option under

 Record Setup > General

 

has been enabled the camera will record audio along with 
video. 

Check your local laws and regulations on making 
audio recordings.

Video Recording Playback

You can play back video recordings by using a mouse or 
remote control.

All Channel Playback

Press the 

Menu

 button while in Live mode.

Select the Search Mode   icon and then select 

Time-

Lapse Search

 or 

Event Log Search

The selected search mode will be initiated.

IDIS Web

IDIS Web is a program that allows you to view and search 
video from remote locations over the Internet and can 
be accessed on a regular web browser such as Internet 
Explorer.
System requirements for running IDIS Web are as follows:

Recommended

OS

Microsoft

®

 Windows

®

 XP (Service Pack 3), 

Microsoft

®

 Windows

®

 Vista (Service Pack 1), 

Microsoft

®

 Windows® 7 (Home Premium, 

Professional, Ultimate) or Microsoft

®

 Windows

®

 

8 (Pro, Enterprise)

CPU

Intel Pentium IV 2.4GHz or above 
(Core 2 Duo E4600 recommended)

RAM

1GB or more

VGA

128MB or more (1280x1024, 24bpp or above)

Internet Explorer

Ver. 7.0 or above (32-Bit)

• 

IDIS Web only works with Microsoft Internet 
Explorer and will NOT work with other browsers.

• 

IDIS Web does not work in Microsoft

®

 Windows

®

 8 

metro UI.

Содержание DR-2308P

Страница 1: ...DR 2304P DR 2308P DR 2316P Network Video Recorder Quick Guide Powered by...

Страница 2: ...d B If liquid is spilled or objects have fallen into the equipment C If the equipment has been exposed to rain or water D If the equipment does not operate normally by following the operating instruct...

Страница 3: ...systems Thismarkingshownontheproductoritsliterature indicatesthatitshouldnotbedisposedwithotherhouseholdwastesattheendofits workinglife Topreventpossibleharmtotheenvironmentorhumanhealthfromuncontroll...

Страница 4: ...wer Cable DC Adapter 12V 48V Quick Guide SATA2 Cables Optical USB Mouse IR Remote Control Assembly Screws for Adding Hard Disk Drives Please download IDIS Center software and product manual from this...

Страница 5: ...f cameras and alarms that can be connected and the number of cameras that can be displayed For simplicity the illustrations and descriptions in this document refer to the 16 channel model Rear Panel D...

Страница 6: ...7 NetworkPort 8 VideoIn Ext Port 9 AlarmConnectionPorts 0 RS 232Port PowerInPort 12V PowerInPort 48V Connections on the Rear Panel D i r e c t I P S w i t c h Camera Network Keyboard POS Sensor VGAMon...

Страница 7: ...Mode Button 8 Thumbnail Button 9 Calendar Button 0 Keylock Button Setup Button Freeze Button Log Button Enter Button Arrow Buttons Alarm Button Sequence Button Zoom Button PTZ Button View Button a Sa...

Страница 8: ...zard Date Time Setup The new date and time settings will only be applied after clicking Next Record Method Setup Record Video Quality Setup Higher recording quality uses up more disk space Finish the...

Страница 9: ...itself may not be visible for scanning and registration by the NVR For more information about supported network devices and models contact your retailer Mode Select the scan mode Advanced Setup If the...

Страница 10: ...d field using the mouse This will bring up a virtual keyboard you can use to assign a password 3 To log out bring up the Live menu and click on Log out using the mouse Find Password 1 Enter a user reg...

Страница 11: ...e place if recording mode is not set to Recycle and the HDD has reached 100 of its capacity Audio Recording If the Record Audio option under Record Setup General has been enabled the camera will recor...

Страница 12: ...cting by entering http web idisglobal com enter the NVR s IP address in the Device Address field Selecting the Use FEN option on the login window allows you to enter the NVR name registered to the FEN...

Страница 13: ...this step will be skipped automatically 6 When the Installation Completed window appears click Close and finish the installation Start Program When IDIS Center software is installed IDIS Center and I...

Страница 14: ...t OK for remote access 6 Click Device Group on the Sites panel and click E at the bottom Add Device Group window will appear Name Enter a name for the device group Location Select an location for the...

Страница 15: ...n your Android device 2 In Play Store Google Play enter IDIS Mobile in the search field 3 Install IDIS Mobile program and open it 4 The start up menu appears when pressing the Menu button on your mobi...

Страница 16: ...to 240ips DR 2308P Up to 120ips DR 2304P If more than 16 cameras from video encoders are registered on the NVR video may not be displayed smoothly in a remote program RECORDING Max Throughput 160Mbps...

Страница 17: ...Embedded Linux Unit Dimensions W x H x D 300mm x 62mm x 231mm 11 8 x2 4 x9 1 Unit Weight 2 3Kg with 1HDD DR 2308P DR 2316P 2 2Kg with 1HDD DR 2304P Working Temperature 0 C to 40 C 32 F 104 F Operatin...

Страница 18: ...IDIS Co Ltd For more information please visit at www idisglobal com...

Отзывы: