Safety Precautions

WARNING

RISK OF ELECTRIC SHOCK

DO NOT OPEN

WARNING

: TO REDUCE THE RISK OF ELECTRIC SHOCK,

DO NOT REMOVE COVER (OR BACK).

NO USER-SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

Important Safeguards

1.  Read Instructions

All the safety and operating instructions should be read before the 

appliance is operated.

2.  Retain Instructions

The safety and operating instructions should be retained for future 

reference.

3.  Cleaning

Unplug this equipment from the wall outlet before cleaning it. Do not 

use liquid aerosol cleaners. Use a damp soft cloth for cleaning.

4.  Attachments

Never add any attachments and/or equipment without the approval 

of the manufacturer as such additions may result in the risk of fire, 

electric shock or other personal injury.

5.  Water and/or Moisture

Do not use this equipment near water or in contact with water.

6.  Placing and Accessories

Do not place this equipment on an wall or ceiling that is not strong 

enough to sustain the camera. The equipment may fall, causing 

serious injury to a child or adult, and serious damage to the 

equipment. Wall or shelf mounting should follow the manufacturer's 

instructions, and should use a mounting kit approved by the 

manufacturer.

This equipment and cart combination should be moved with care. 

Quick stops, excessive force, and uneven surfaces may cause the 

equipment and cart combination to overturn.
Do not place this equipment in an enclosed space. Sufficient 

ventilation is required to prevent an increase in ambient temperature 

which can cause malfunction or the risk of fire.

7.  Power Sources

This equipment should be operated only from the type of power 

source indicated on the marking label. If you are not sure of the 

type of power, please consult your equipment dealer or local power 

company.

You may want to install a UPS (Uninterruptible Power Supply) 

system for safe operation in order to prevent damage caused by an 

unexpected power stoppage. Any questions concerning UPS, consult 

your UPS retailer.

8.  Power Cord

Operator or installer must remove power and TNT connections before 

handling the equipment.

9.  Lightning

For added protection for this equipment during a lightning storm, 

or when it is left unattended and unused for long periods of time, 

unplug it from the wall outlet and disconnect the antenna or cable 

system. This will prevent damage to the equipment due to lightning 

and power-line surges. If thunder or lightning is common where the 

equipment is installed, use a surge protection device.

10.  Overloading

Do not overload wall outlets and extension cords as this can result in 

the risk of fire or electric shock.

11.  Objects and Liquids

Never push objects of any kind through openings of this equipment 

as they may touch dangerous voltage points or short out parts that 

could result in a fire or electric shock. Never spill liquid of any kind on 

the equipment.

12.  Servicing

Do not attempt to service this equipment yourself. Refer all servicing 

to qualified service personnel.

13.  Damage requiring Service

Unplug this equipment from the wall outlet and refer servicing to 

qualified service personnel under the following conditions:
A.  When the power-supply cord or the plug has been damaged.
B.  If liquid is spilled, or objects have hit the equipment.
C.  If the equipment has been exposed to rain or water.
D.  If the equipment does not operate normally by following the 

operating instructions, adjust only those controls that are covered 

by the operating instructions as an improper adjustment of other 

controls may result in damage and will often require extensive work 

by a qualified technician to restore the equipment to its normal 

operation.

E.  If the equipment has been dropped, or the cabinet damaged.
F.  When the equipment exhibits a distinct change in performance — 

this indicates a need for service.

14.  Replacement Parts

When replacement parts are required, be sure the service technician 

has used replacement parts specified by the manufacturer or that 

have the same characteristics as the original part. Unauthorized 

substitutions may result in fire, electric shock or other hazards.

15.  Safety Check

Upon completion of any service or repairs to this equipment, ask the 

service technician to perform safety checks to determine that the 

equipment is in proper operating condition.

16.  Field Installation

This installation should be made by a qualified service person and 

should conform to all local codes.

17.  Tmra

A manufacturer’s maximum recommended ambient temperature 

(Tmra) for the equipment must be specified so that the customer and 

installer may determine a suitable maximum operating environment 

for the equipment.

Содержание DirectIP DC-E Series

Страница 1: ...Powered by DC E Series Installation Manual DC E4513WRX...

Страница 2: ...problems resulting from the use thereof The information contained herein is subject to change without notice Revisions or new editions to this publication may be issued to incorporate such changes It...

Страница 3: ...and unused for long periods of time unplug it from the wall outlet and disconnect the antenna or cable system This will prevent damage to the equipment due to lightning and power line surges If thund...

Страница 4: ...lth from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact ei...

Страница 5: ...view 8 Body 8 Cable 9 Installation 9 Inserting a SD Memory Card 10 Waterproof Cable Installation 10 Installation 11 Dimensions 12 Part 2 Camera Connection 13 With DirectIP NVR based Layout 13 With non...

Страница 6: ...ility Remote monitoring via web browser or remote software Automatic web casting code HTML generation Up to 10 simultaneous remote monitoring connections IP filtering HTTPS SSL IEEE 802 1X and configu...

Страница 7: ...essories are included External appearances and colors of the accessories may vary depending on the model Network Camera RJ45 moduler jack RJ45 waterproof rubber ring RJ45 connector protect cover cable...

Страница 8: ...s rear side s cover in order to remove or insert the SD memory card Make sure that the cover is joined properly when screwing it otherwise the IP66 level is not guaranteed To remove insert the SD memo...

Страница 9: ...V to 5V In order to detect alarm input from an electrical switch the signal must be higher than 4 3V from an NC switch or less than 0 3V from an NO switch and must last for longer than 0 5 seconds Ala...

Страница 10: ...el is not guaranteed Waterproof Cable Installation 1 2 3 4 RJ45 waterproof rubber ring RJ45 modular jack RJ45 connector protect cover cable waterproof rubber ring The waterproof rubber ring is fastene...

Страница 11: ...he wall or ceiling is not strong enough to support its weight Install the camera in a shaded area If the camera is installed in direct sunlight it may be affected adversely 1 Screw the mounting bracke...

Страница 12: ...Part 1 Introduction 12 3 Connect external devices network and power adapter 4 Apply power Dimensions f 2 8mm 195 8mm 17mm 85 8mm 80mm 30mm f 4 0mm 6 0mm 197mm 75mm 70mm 90 80mm 85 8mm 31 2mm 17mm...

Страница 13: ...er Remote Monitoring Monitor Out Audio In DirectIP NVR makes it easy to use cameras without extra network configurations Each camera can be controlled via the DirectIP NVR setup menu without any PC Fo...

Страница 14: ...te Compact Alarm Out Audio Out Audio In Sensor In microSD Memory Card Control the camera over the network from software installed on a computer Ideal for using the camera over the network from a remot...

Страница 15: ...st the camera s position angle accordingly Video color appears incorrect Check the white balance settings If using the Auto option it may take some time for the white balance to be adjusted Images are...

Страница 16: ...Range 120dB True WDR Electronic Shutter Speed Auto Manual 1 30 1 10 000 Anti Flicker Slow Shutter 1 1 5 1 7 5 1 15 Day Night IR cut filter with auto switch IR Distance LEDs 20m 4ea f 2 8mm 30m 4ea f...

Страница 17: ...io In Out Line in 1ea Line out 1ea Alarm In 1 TTL NC NO Programmable 4 3V NC or 0 3V NO threshold 5V DC Alarm Out 1 TTL open collector Max load 30mA Max voltage 5VDC General Vandal Resistance Yes Out...

Страница 18: ...IDIS Co Ltd For more information please visit at www idisglobal com...