Part 1 - Remote Setup
31
Face Detection
Select Face Detection to configure face detection event
settings. With face detection event enabled, detections
of face with designated size will be assumed as events.
•
Max Detect Count: Select the number of faces to
be detected. Only the designated number of faces is
detected when a face detection event occurs.
•
Sensitivity: Select face detection sensitivity levels.
Higher values will result in more sensitive face
detection. If Max. Detect Count is set to 32, faces are
detected in the sensitivity level of 5.
•
Minimum Face Size: Select the face size for event
detection. A face size must be bigger than the
designated size in order for it to be considered as a
face detection event.
•
Event Action: Select a motion detection event alert
action.
- Alarm Out: Select if you wish to generate an alarm
out.
- Send Email: Select if you wish to send an email.
Select the Image Attachment option to attach a
.jpg image of the event detected to the email.
- Remote Callback: Select this option to send a
message to a remote system and then select which
system to send the message to.
•
Not supported from the IDIS Web program.
•
The camera must be registered to the remote
system in order to use the Remote Callback
feature.
- Audio Alarm: Select this option to generate an
audio alert and then choose an audio file (.wav).
- FTP Upload: Select this option if you wish to
upload images to the FTP server.
Event Action settings must be configured correctly
in order to perform event actions.