Before reading this manual

3

Safety Precautions

WARNING

RISK OF ELECTRIC SHOCK

DO NOT OPEN

WARNING

: TO REDUCE THE RISK OF ELECTRIC SHOCK,

DO NOT REMOVE COVER (OR BACK).

NO USER-SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

Important Safeguards

1.  Read Instructions

All the safety and operating instructions should be read before the 
appliance is operated.

2.  Retain Instructions

The safety and operating instructions should be retained for future 
reference.

3.  Cleaning

Unplug this equipment from the wall outlet before cleaning it. Do not 
use liquid aerosol cleaners. Use a damp soft cloth for cleaning.

4.  Attachments

Never add any attachments and/or equipment without the approval 
of the manufacturer as such additions may result in the risk of fire, 
electric shock or other personal injury.

5.  Water and/or Moisture

Do not use this equipment near water or in contact with water.

6.  Placing and Accessories

Do not place this equipment on an wall or ceiling that is not strong 
enough to sustain the camera. The equipment may fall, causing 
serious injury to a child or adult, and serious damage to the 
equipment. Wall or shelf mounting should follow the manufacturer's 
instructions, and should use a mounting kit approved by the 
manufacturer.

This equipment and cart combination should be moved with care. 
Quick stops, excessive force, and uneven surfaces may cause the 
equipment and cart combination to overturn.
Do not place this equipment in an enclosed space. Sufficient 
ventilation is required to prevent an increase in ambient temperature 
which can cause malfunction or the risk of fire.

7.  Power Sources

This equipment should be operated only from the type of power 
source indicated on the marking label. If you are not sure of the 
type of power, please consult your equipment dealer or local power 
company. You may want to install a UPS (Uninterruptible Power 
Supply) system for safe operation in order to prevent damage caused 
by an unexpected power stoppage. Any questions concerning UPS, 
consult your UPS retailer.
This equipment should be remain readily operable.

8.  Power Cord

Operator or installer must remove power and TNT connections before 
handling the equipment.

9.  Lightning

For added protection for this equipment during a lightning storm, 
or when it is left unattended and unused for long periods of time, 
unplug it from the wall outlet and disconnect the antenna or cable 
system. This will prevent damage to the equipment due to lightning 
and power-line surges. If thunder or lightning is common where the 
equipment is installed, use a surge protection device. 

10.  Overloading

Do not overload wall outlets and extension cords as this can result in 
the risk of fire or electric shock.

11.  Objects and Liquids

Never push objects of any kind through openings of this equipment 
as they may touch dangerous voltage points or short out parts that 
could result in a fire or electric shock. Never spill liquid of any kind on 
the equipment.

12.  Servicing

Do not attempt to service this equipment yourself. Refer all servicing 
to qualified service personnel.

13.  Damage requiring Service

Unplug this equipment from the wall outlet and refer servicing to 
qualified service personnel under the following conditions:
A.  When the power-supply cord or the plug has been damaged.
B.  If liquid is spilled, or objects have hit the equipment.
C.  If the equipment has been exposed to rain or water.
D.  If the equipment does not operate normally by following the 

operating instructions, adjust only those controls that are covered 
by the operating instructions as an improper adjustment of other 
controls may result in damage and will often require extensive work 
by a qualified technician to restore the equipment to its normal 
operation.

E.  If the equipment has been dropped, or the cabinet damaged.
F.  When the equipment exhibits a distinct change in performance — 

this indicates a need for service.

14.  Replacement Parts

When replacement parts are required, be sure the service technician 
has used replacement parts specified by the manufacturer or that 
have the same characteristics as the original part. Unauthorized 
substitutions may result in fire, electric shock or other hazards.

15.  Safety Check

Upon completion of any service or repairs to this equipment, ask the 
service technician to perform safety checks to determine that the 
equipment is in proper operating condition.

16.  Field Installation

This installation should be made by a qualified service person and 
should conform to all local codes.

17.  Correct Batteries 

Warning: Risk of explosion if battery is replaced by an incorrect type.
Replace only with the same or equivalent type.
Dispose of used batteries according to the instructions.
The battery shall not be exposed to excessive heat such as sunshine, 
fire or the like.

18.  Tmra

A manufacturer’s maximum recommended ambient temperature 
(Tmra) for the equipment must be specified so that the customer and 
installer may determine a suitable maximum operating environment 
for the equipment.

Содержание DC-D4536HRX

Страница 1: ...Powered by Network Camera Installation Manual DC D4536RX DC D4536HRX DC D4536RX A DC D4536HRX A...

Страница 2: ...h explanation about some functions may not be incorporated The manufacturer is not responsible for any problems resulting from the use thereof The information contained herein is subject to change wit...

Страница 3: ...le system This will prevent damage to the equipment due to lightning and power line surges If thunder or lightning is common where the equipment is installed use a surge protection device 10 Overloadi...

Страница 4: ...to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources H...

Страница 5: ...Reset 12 Lens 12 Installation 12 Removing the Dome Cover 12 Inserting a SD Memory Card 13 Installation 14 Angle Adjustment 16 Closing the Dome Cover 16 Dimension 17 Part 2 Camera Connection 19 With Di...

Страница 6: ...hout a PC Supports ONVIF protocol Core specification version 2 4 0 Profile S Multi streaming for high resolution and high quality video monitoring and simultaneous recording in real time as well as fl...

Страница 7: ...tion modes Backup storage on a micro SD memory card as a safeguard against data loss during network interruptions Supports 12 VDC and PoE Power over Ethernet Includes a motorized focus and zoom lens F...

Страница 8: ...6RX A DC D4536HRX DC D4536HRX A Terminal Blocks 2 ea Network Camera Desiccant 3ea double sided tape 2ea Allen Wrench Quick Guide DC D4536RX DC D4536RX A DC D4536HRX DC D4536HRX A Screws and Anchors ea...

Страница 9: ...Part 1 Introduction 9 Overview Dome Cover DC D4536RX DC D4536RX A DC D4536HRX DC D4536HRX A Body DC D4536RX DC D4536RX A 1 2 3 4 8 9 0 7 5 6 5...

Страница 10: ...5 connector to this port If using a PoE switch you can supply power to the camera using an Ethernet cable For more information on PoE switch use refer to the switch manufacturer s operation manual You...

Страница 11: ...ranscend is recommended Do not remove the SD memory card while the system is in operation Removing the card while the system is in operation can cause the system to malfunction and or corrupt data sto...

Страница 12: ...ctory reset by pressing and releasing the reset button while the camera is turned on or using the IDIS Discovery program from a remote location A factory reset will reboot the system For more informat...

Страница 13: ...h the product 2 Remove the dome cover Inserting a SD Memory Card Insert a SD memory card into the SD memory card slot with the micro SD print facing upward DC D4536RX DC D4536RX A micro SD micro SD DC...

Страница 14: ...a to secure the install bracket on a wall or a ceiling Use the provided guide pattern to check the distance between the screws 2 Connect external devices the network cable and the power adapter 3 Adju...

Страница 15: ...cable rubber to the bottom cover 5 Attach the enclosed desiccant in the bottom to prevent moisture Desiccant 6 Use the screws anchor provided with the camera to secure the install body on a wall or a...

Страница 16: ...angle Turn the horizontal rotator in the clockwise or counterclockwise direction Closing the Dome Cover DC D4536RX DC D4536RX A Attach the dome cover to the bottom cover Turn the dome cover clockwise...

Страница 17: ...on 17 2 Fasten the screws for the dome cover clockwise using the Allen wrench provided with the camera Remove the protective film inside and outside Dimension DC D4536RX DC D4536RX A 122 4mm 103 40mm...

Страница 18: ...Part 1 Introduction 18 DC D4536HRX DC D4536HRX A 155mm 100mm 104 4mm 46 3mm 5 9mm...

Страница 19: ...Out Alarm Out Sensor In Audio In Network DirectIP NVR makes it easy to use cameras without extra network configurations Each camera can be controlled via the DirectIP NVR setup menu without any PC Fo...

Страница 20: ...e Compact microSD Memory Card Alarm Out Sensor In Audio Out Audio In or Control the camera over the network from software installed on a computer Ideal for using the camera over the network from a rem...

Страница 21: ...h Make sure the lens is in focus Adjust the focus during daytime If there is too much light coming into the camera or the camera is picking up an overly bright light source adjust the camera s positio...

Страница 22: ...ion COLOR 0 15 lux F1 4 B W 0 lux IR LED ON Dynamic Range 120dB True WDR Electronic Shutter Speed Auto Manual 1 30 1 10 000 Anti Flicker Slow Shutter 25 ips 1 12 5 1 6 25 30ips 1 15 1 7 5 Day Night IR...

Страница 23: ...TTL NC NO Programmable 4 3V NC or 0 3V NO threshold 5V DC Alarm Out 1 TTL open collector Max load 30mA Max voltage 5VDC General Operating Temperature DC D4536RX DC D4536RX A 10 C 50 C 14 F 122 F DC D...