REV6 OPERATION / MAINTENANCE MANUAL
32
CONTENTS
5.1.4 Error Display on the Integrated Panel
Error
Source
Errors
Error Code
on Display
Motor
No motor
Er 01
Motor
Motor cable (power wires) not connected to controller
Er 02
Motor
Motor cable (sensor wires) not connected to controller
Er 03
Motor
No impeller
Er 04
Controller Short circuit
Er 05
Controller Over current in the bearing coils
Er 06
Controller Over current in the drive coils
Er 07
Controller DC-Link voltage out of range (< 40 or > 54 V DC)
If the voltage is out of range the system starts to reduce the speed and a warning is generated. When
reaching 0 rpm and the voltage is still out of range the system is disabled and an error is generated. In
case the voltage is again within the range during speed reduction the system switches to normal
operation and no Error is generated.
Er 08
Controller Communication problems EEPROM Controller
Er 09
Motor
Communication problems EEPROM Motor
Er 10
Controller Controller temp. over 80°C or more than 10 minutes above 70°C
Er 11
Motor
Motor temp. over 100°C or more than 10 minutes above 90°C
Er 12
Pump
Dry running of pump circuit:
-> Pump keeps running on reduced speed (5000 rpm) -> The system accelerates to the original speed
value when the pump is refilled with liquid. -> Note that the speed is only reduced during dry running if
the pump speed was ≥ 6000 rpm.
Blinking
dots on
display
Table 11 - Errors and Warnings with Indication on Standalone Controller Display
-
In case of an error the system can only be restarted with a reset or a power supply restart
- For other configurations of error codes refer to alternate controller or firmware documentation