0901133 Rev: A (11/13) 

Page 3 of 20 

QUICK-START PROGRAMMING 

The steps below will give you just the basics to quickly setup a new system — more details and complete 
programming information are included in the following pages of this manual. 

(1)  Press 

 once (for default 000 access code). 

(2)  Press ENTER...―ACC‖ will flash briefly on the display. You now have access. 

(3)  Note that the pump time LED will be flashing. 

(4)  Press pump SELECT until desired pump number is displayed. 

NOTE: If using a flush manifold, program pump ―F‖ on all formulas to set flush time. 

(5)  Press formula SELECT until desired formula number appears. 

(6)  Use 

/

 to input the pump time or flush time (or delay time) in seconds. 

(7)  Press ENTER…the display will flash indicating that your entry has been saved. 

(8)  To program a pump delay time, press MODE until delay time LED is flashing. Repeat steps 4 – 7. 

(9)  To set the load count pump, press ENTER twice (note that pump time & delay time LEDs turn off). Use pump 

SELECT to choose the pump number that will be used to count loads for each formula. After a few seconds, the 
pump time LED will return, indicating that your entry has been saved. 

(10) Press RESET when finished programming and ready to run. 

2  7 

10 

Содержание Knight On-Premise Pro

Страница 1: ...0901133 Rev A 11 13 Page 1 of 20 On Premise Pro Instruction Manual...

Страница 2: ...C 2 0 A 50 60 Hz 6 Indoor use only 7 Temperature 5 C to 40 C 8 Mains supply voltage fluctuations are not to exceed 10 percent of the nominal supply voltage Electrical Ratings Chemical dispensing pumps...

Страница 3: ...ump F on all formulas to set flush time 5 Press formula SELECT until desired formula number appears 6 Use to input the pump time or flush time or delay time in seconds 7 Press ENTER the display will f...

Страница 4: ...ected by voltage spikes or power outages Optional Drain Mode and Relay Mode Optional Auto Formula Select Formula and level enable disable capability Flush mode can be used with all modes of operation...

Страница 5: ...voltage cables do not require conduit 5 Install and wire the Signal Interface Module SIB per notes to the right 6 For each pump cut the suction tube to length and insert one end into the appropriate...

Страница 6: ...r contact at the flow switch terminals see wiring diagram to verify proper flush If a flow switch is not used jumper JP1 should be in place A flush error happens when no contact is detected switch or...

Страница 7: ...tinue where you left off Entering the access code Do not access the system while pumps are being signaled from the washer Use whichever of the following two procedures that applies If the system is ne...

Страница 8: ...ump time LED is flashing If the delay time LED is flashing press MODE to choose pump time 4 Choose the desired pump and formula using their respective SELECT buttons 5 Position your container below th...

Страница 9: ...y advance the numbers 6 Press ENTER and the display will flash briefly indicating that the delay time was accepted NOTE During delay time countdown will display indicating a countdown in one minute in...

Страница 10: ...this is normal 4 After a few seconds the pump time LED will return indicating the pump number was accepted 5 If the pump time LED returns before the desired pump has been chosen repeat steps 2 3 To vi...

Страница 11: ...ula A 3 Use to choose 000 disable or 001 enable on the 3 digit display then ENTER 4 The display will flash briefly indicating that the enable disable status was accepted Assigning drain numbers 1 Ente...

Страница 12: ...A new dispenser from the factory will already have these pumps disabled Also when clearing the memory pumps 7 8 are disabled by default 1 Enter the access code if you do not already have access to th...

Страница 13: ...ontrol This makes the remote control more user friendly to the operators and eliminates the chance of missed chemical injections due to inadvertently choosing an unused formula By default for a new di...

Страница 14: ...turned off disabled 4 The display will flash briefly indicating that the auto formula select time was accepted NOTE If AFS is enabled the system is limited to 5 chemical pumps as pump 6 is dedicated...

Страница 15: ...se pump motor wires Check for voltage from circuit board to motor Check for mechanical binding of moving parts Flush errors keep occurring Check to see if a flush manifold is used if so is it operatin...

Страница 16: ...Page 16 of 20 0901133 Rev A 11 13 SYSTEM WIRING DIAGRAM...

Страница 17: ...0901133 Rev A 11 13 Page 17 of 20 SYSTEM PARTS DIAGRAM...

Страница 18: ...Page 18 of 20 0901133 Rev A 11 13 SYSTEM PARTS DIAGRAM...

Страница 19: ...0901133 Rev A 11 13 Page 19 of 20...

Страница 20: ...tory authorized inspection Bearings and pump seals or rubber and synthetic rubber parts such as O rings diaphragms squeeze tubing and gaskets are considered expendable and are not covered under warran...

Отзывы: