38
4.3.1.7
Pump Controller System Options Menu
Touch the systems options button (touch and hold the button if the loading icon appears) to dis-
play the system options Menu screen (Figure 50). The screen displays four (4) separate areas on
the screen: The datalogger export control, the Back To Previous Menu button, the Revision Sta-
tus information and the Password Entry button. See paragraph 6.3.3.5, Exporting The Datalogger
File, page 98, to utilize the Export Datalogger controls.
Figure 50. Pump Controller System Options Menu
Touch the Back To Previous Menu button (see Table 3) to return to the default Pump Controller
screen. The screen displayed varies depending on the SAM mode (Auto or Manual) and then the
current state of the governor.
4.4
Optional Remote Capability
The SAM system provides two remote control options. The first option utilizes optional SAM Con-
trol Centers (auxiliary screens) which are located away from the standard SAM Control Center
(master screen) which is always located in the pump panel. See paragraph 4.4.1 (page 38) for
optional SAM Control Centers (auxiliary screens) details.
The second option utilizes the SAM tablet connected via secure wi-fi. See paragraph 4.4.3 (page
38) for the details concerning the optional SAM tablet (a portable/free roaming SAM Control Cen-
ter) and paragraph 4.4.2 (page 38) for secure wi-fi information.
4.4.1
Auxiliary SAM Control Center Screens
Up to two optional SAM Control Centers (auxiliary screens) can be installed on the apparatus,
Typical locations for remotely located SAM Control Centers are; the panel opposite the pump
panel (passengers side of apparatus), the rear of the apparatus, or at an aerial location.
4.4.2
Secure WI-FI (Router/Antenna)
The SAM Control Center (master) transmits via secure wi-fi to the SAM tablet. The wi-fi connec-
tion is more secure than typical wi-fi connections because the router/antenna ensures that ONLY
the tablet paired with that SAM Control Center can communicate with that SAM system and the
SAM wi-fi transmission is hidden from all other wi-fi devices.
4.4.3
Ruggedized Tablet
The SAM ruggedized tablet (Figure 51) allows pump control/operation from anywhere in close
proximity to the apparatus where the tablet can maintain wi-fi connectivity with the master SAM
Control Center. The tablet provides an 8-in diagonal screen, weighs approximately 2 lbs, is IP 65,
and utilizes 10-point projection capacitive touch (supporting use in rain and with thin gloves). The
tablet utilizes a standard battery (provides up to 9 hrs) and supports Wi—Fi (wireless 802.11
a/b/g/n/ac).