Idex GAST 15D Series Скачать руководство пользователя страница 4

SERVICE KIT INSTALLATION

c

Disconnect electrical power supply cord before

installing Service Kit.
If product is hard wired into system, disconnect

electrical power at the circuit breaker or fuse box

before installing Service Kit.
Disconnect air supply and vent all air lines to

release pressure or vacuum.
Failure to follow these instructions can result in

death, fire or electrical shock.

WARNING

Electrical Shock Hazard

Gast will NOT guarantee field-rebuilt product performance.

For performance guarantee, the product must be returned

to a Gast Authorized Service Facility.

Disassembly

To make reassembly easier, note the location of parts when

disassembling.

1. Disconnect electrical power to pump.

2. Disconnect air supply and vent all air lines to release

pressure or vacuum.

3. Note the direction of the arrows so you can orient

the pump head correctly during reinstallation.

4. Remove the four corner head screws and remove

the head, valve and valve plate.

5. Remove retainer plate and diaphragm.

6. Clean the pump using water-based solvents.

CAUTION: Do not use petroleum-base

compounds, acids, caustics or chlorinated solvents to clean

or lubricate parts. It will reduce service life of unit.

4

Solvent Cleaning

Use only Gast AH255B Solvent or other

non-petroleum based solvent. Do Not use kerosene or

ANY other combustible solvent to clean product.

WARNING

May contain solid or liquid material

that can result in eye or skin damage.

Wear eye protection when using this product.

Solvent Stream

Reassembly

1. Reattach retainer plate and diaphragm to rod with

retainer screw

2. Torque screw to 12 in-lbs.

3. Re-install valve plate, valve and head.

4. Re-install head screws and torque to 12 in-lbs.

CAUTION:

Do not over-tighten head screw(s). To do so can

damage unit and will reduce performance.

If pump still does not produce proper vacuum or pressure,

send unit to a Gast Authorized Service Facility for repair.

SHUTDOWN PROCEDURES

It is your responsibility to follow proper shutdown

procedures to prevent product damage.

NEVER ADD OIL TO THIS OIL-LESS PUMP.

Proper shutdown procedures must be followed to

prevent pump damage. Failure to do so may result in

premature pump failure. Follow all the steps to

assure correct storage and shutdown between

operating periods.

It is your responsibility to:

• Regularly inspect and make necessary repairs to

product in order to maintain proper operation.

• Make sure that pressure and vacuum are released

from product before starting maintenance.

Injury Hazard

Product surfaces become very hot during operation,

allow product surfaces to cool before handling.
Air stream from product may contain solid or liquid

material that can result in eye or skin damage,

wear proper eye protection.
Clean this product in a well ventilated area.
Failure to follow these instructions can result in

burns, eye injury or other serious injury.

WARNING

1. Disconnect plumbing.

2. Operate product for at least 5 minutes without

plumbing.

3. Disconnect power supply.

4. Plug open ports to prevent dirt or other

contaminants from entering product.

Содержание GAST 15D Series

Страница 1: ... oil less and requires NO lubrication Units may be used for both pressure and vacuum Thank you for purchasing this Gast product It is manufactured to the highest standards using quality materials Please follow all recommended maintenance operational and safety instructions and you will receive years of trouble free service www gastmfg com ISO 9001 14001 CERTIFIED Registered Trademark Trademark of ...

Страница 2: ...t plumbing 2 Check with a qualified electrician or serviceman if the grounding instructions are not completely understood or if you are not sure whether the product is properly grounded Do not modify the plug provided If it will not fit the outlet have the proper outlet installed by a qualified electrician In the event of an electrical short circuit grounding reduces the risk of electric shock by ...

Страница 3: ... 16 14 12 12 10 10 8 4 5 18 18 14 12 12 10 10 8 8 5 6 18 16 14 12 10 10 8 8 8 6 8 18 16 12 10 10 8 6 6 6 8 10 18 14 12 10 8 8 6 6 4 10 12 16 14 10 8 8 6 6 4 4 12 14 16 12 10 8 6 6 6 4 2 14 16 16 12 10 8 6 6 4 4 2 16 18 14 12 8 8 6 4 4 2 2 18 20 14 12 8 6 6 4 4 2 2 An undersized cord is a potential fire hazard and will cause a drop in line voltage resulting in loss of power causing the product to o...

Страница 4: ...in damage Wear eye protection when using this product Solvent Stream Reassembly 1 Reattach retainer plate and diaphragm to rod with retainer screw 2 Torque screw to 12 in lbs 3 Re install valve plate valve and head 4 Re install head screws and torque to 12 in lbs CAUTION Do not over tighten head screw s To do so can damage unit and will reduce performance If pump still does not produce proper vacu...

Страница 5: ...t contains 1 valve and 1 diaphragm For Twin Models please order 2 kits Gast Hong Kong Unit 12 21 F Block B New Trade Plaza 6 On Ping Street Shatin N T Hong Kong Ph 852 2690 1008 Fax 852 26901012 www gastmfg com World Headquarters P O Box 97 2550 Meadowbrook Rd Benton Harbor MI 49023 0097 Ph 269 926 6171 FAX 269 925 8288 www gastmfg com Parts listed are for stock models For specific OEM models plea...

Страница 6: ...NTIAL DAMAGES OF ANY KIND however arising including but not limited to those for use of any products loss of time inconvenience lost profit labor charges or other incidental or consequential damages with respect to persons business or property whether as a result of breach of warranty negligence or otherwise Notwithstanding any other provision of this warranty BUYERʼS REMEDY AGAINST GAST FOR GOODS...

Отзывы: