CTB-12
AT1500 Canister Remapping
6/27/19
Original Release
Reformatted document, re-released.
Fluid Management
Technical Support
AT1500HS Canister Remapping
PRODUCT(S)
AT1500HS
PURPOSE
This instruction is for all customers using Fluid Management’s ColorPro 4.x. software.
Follow this procedure if the pump or agitation motor has failed and there is a spare
position available.
INSTRUCTIONS
1. Close the ColorPro program
2. Click on
SERVICE.EXE
bridge
on your desktop
3. Enter password
service
4. Click on
Setup (F4)
5. Click on the
Canister
tab
6. Click on the spare to activate and click
Enter
on your keyboard
7. Wait for the pulse test to complete
8. The spare canister should be activated when the number box goes from black to
grey
9. Click on
Options (F5)
10. Click on the color that is not dispensing
11.
Rename it “Spare” under ingredient name
a.
For example, if the “C” colorant is not dispensing, click on the “C” colorant
and rename it to “Spare”
12. Click
Apply
, then click
OK
to save the changes
13. Click on
Options (F5)
14. Click on the spare canister position just activated