Fluid Management 

Technical Support 

 

AT1500HS Canister Remapping

 

PRODUCT(S) 

AT1500HS 

PURPOSE  

This instruction is for all customers using Fluid Management’s ColorPro 4.x. software. 
Follow this procedure if the pump or agitation motor has failed and there is a spare 
position available. 

INSTRUCTIONS 

1.  Close the ColorPro program 

2.  Click on 

SERVICE.EXE 

bridge

 

on your desktop 

3.  Enter password 

service

 

4.  Click on 

Setup (F4)

 

5.  Click on the 

Canister 

tab 

6.  Click on the spare to activate and click 

Enter

 on your keyboard 

7.  Wait for the pulse test to complete 

8.  The spare canister should be activated when the number box goes from black to 

grey 

9.  Click on 

Options (F5)

 

10. Click on the color that is not dispensing 

11. 

Rename it “Spare” under ingredient name 

a. 

For example, if the “C” colorant is not dispensing, click on the “C” colorant 
and rename it to “Spare” 

12. Click 

Apply

, then click 

OK

 to save the changes 

13. Click on 

Options (F5)

 

14. Click on the spare canister position just activated 