background image

18

5

Troubleshooting

5.1

General troubleshooting procedure

1. Try to solve the problem with the information in this manual. 

See

§ 5.3

.

2. If it is not possible to solve the problem with the information in 

this manual, contact service. See

§ 5.2

.

5.2

Contact service

1. Find the type plate on the plate next to the emergency stop 

switch. See 

§ 3.1.4

.

2. Take a note of the model number and the serial number of the 

machine.

3. Contact your supplier or manufacturer. 

See 

www.fast-fluid.com

 (Fast & Fluid Management Europe 

and Asia) or 

www.fluidman.com

 (Fluid management, U.S.A.).

5.3

Troubleshooting guide

Note

For all error messages on the computer: see the 
help topic in the dispense software.

Problem

Possible cause

Possible solution

Main power supply is 
present but the machine 
does not work.

The emergency stop switch is 
active.

Reset the emergency stop switch. 
See 

§ 3.2.3

.

The machine has a failure 
and does not respond 
correctly to the request from 
the dispense software.

The failure could be mechanically 
or electronically.

Push the emergency stop switch to reset 
the machine. Reset the emergency stop 
switch. See 

§ 3.2.3

.

If the machine still has a failure, contact 
service. See 

§ 5.2

.

Troubleshooting 

X-Smart

V 1.4

Содержание Fast & Fluid X-SMART

Страница 1: ...Original Manual X Smart www fluidman com V 1 4 www fast fluid com...

Страница 2: ...f Fast Fluid Management B V to notify any person of such revision or change Details and values given in this manual are average values and have been compiled with care They are not binding however and...

Страница 3: ...ription 9 3 1 1 Overview of the machine 9 3 1 2 Overview of the available optional parts 10 3 1 3 Type plate serial number 11 3 1 4 Type plate details 11 3 2 Operation 11 3 2 1 General dispensing proc...

Страница 4: ...ooting guide 18 6 Technical data 19 6 1 General specifications 19 6 2 Dimensions and mass 19 6 3 Ambient conditions 20 6 4 Noise level 20 6 5 Safety classifications 20 6 6 Electrical specifications 20...

Страница 5: ...structure and content 2 To read the safety chapter in detail and make sure you understand all the instructions See chapter 2 3 To carry out the actions completely and in the given sequence 1 2 Record...

Страница 6: ...the instructions in this manual Connect the machine to a grounded wall socket Do not use extension cords or inadequately rated power cables Make sure that the power cable is freely accessible Do not...

Страница 7: ...if you have written permission from the supplier of the machine 2 4 Certifications For some markets machines need a certification to proove the machine complies with the essential requirements concer...

Страница 8: ...g 2 Do not dispose of the machine into domestic waste Dispose of the machine according to local regulations 3 Dispose of the canisters as chemical waste according to the local regulations Moving parts...

Страница 9: ...w of the machine A Top cover B Canister C Pump D Slot for the can table E Nozzle F Can sensor G Can table H Emergency stop switch I Brush unit J Turntable K Agitator part of the stirring mechanism F G...

Страница 10: ...10 3 1 2 Overview of the available optional parts A Monitor Keyboard arm B Wrap B A Operator manual X Smart V 1 4...

Страница 11: ...ast fluid com www fluidman com INDEX India Pvt Ltd Survey no 256 GIDC Manjusar Savli Dist Vadodara 391 770 INDIA Model Serial No XXXXXX XX XXXX Prod Week XXXXXXXXX XXXXXX xx xx V xx W xx xx Hz X Wire...

Страница 12: ...The correct height of the can table depends on the height of the can CAUTION Make sure that the can table is secure CAUTION Make sure that the can does not touch the turntable E Keep enough free spac...

Страница 13: ...ce tasks and a reminder to keep your machine in optimal condition Replace the brush unit C every 4 months for optimal performance Use the X Smart paper funnels D for the clean filling and refilling of...

Страница 14: ...with a click connection It is advised to replace the brush unit every 4 months to ensure optimal performance Replacement brush units are provided in the X Smart Maintenance Kit 1 Slide the brush unit...

Страница 15: ...liquids in the brush container Note Do not exceed the maximum filling height F Note The optimum fluid level depends on the type of colorant that is used A B Note The brush unit is properly connected t...

Страница 16: ...e colorant CAUTION Make sure that the colorant level in the canister is correct If a canister is empty it can cause an inaccurate dispensing and or a recipe fault Note The dispense software checks the...

Страница 17: ...ut of the pumps See 4 3 4 3 Flushing the air out of the pump 1 Flush the air out of the pump Use the air flushing command in the dispense software If the dispense software does have an air flushing co...

Страница 18: ...nt Europe and Asia or www fluidman com Fluid management U S A 5 3 Troubleshooting guide Note For all error messages on the computer see the help topic in the dispense software Problem Possible cause P...

Страница 19: ...l oz 0 077 0 0026 Nozzle diameter mm in 4 0 517 Parameter Specification Metric standard Imperial standard Dimensions height x width x depth cm in 125 x 83 x 95 49 2 x 32 7 x 37 4 Packed dimensions hei...

Страница 20: ...level out of operation m ft 10 to 12000 33 to 39370 Maximum Relative Humidity without condensation RH 90 Parameter Specification Maximum noise level dB A 65 Parameter Specification IP Ingress Protecti...

Страница 21: ...e 17 4 2014 2 02 NvB NvB NvB 21 1 2013 2 0 3 4 2013 2 01 2 02 Revnr Sheet Title Date Drawn Remarks Filename FAST FLUID Version The Netherlands 2170 AE Sassenheim PO Box 220 Hub v Doorneweg 31 Fast FLu...

Страница 22: ...Manufactured by IDEX India Pvt Ltd Survey no 256 GIDC Manjusar Savli Dist Vadodara 391 770 India 22...

Отзывы: