address 4).  All REMOTE displays that are to mimic the MASTER display must have their addresses 

matching the MASTER

’s. 

The display can also be configured to mimic a Class 1 Pump Sensor Module (p/n 111097) by entering the 
password for the desired tank (

LRRR LRLL 

PCM tank 1, 

LRRR RLRL 

PCM tank 2, 

LRRR RLRR 

PCM tank 3).   

 

3.8.  Configure a custom message scroll  

The ITL40 scrolls a custom message during start-

up.  The default scroll text is “Class 1” but the text can be custom 

configured to a desired message (maximum of 21 characters allowed). 
 
List of available characters. 

SP 

 

 
Enter the password 

LLLL LRLR

 and the display will show the first available character - 

“A”.   

 

Use the LEFT and RIGHT magnetic switches to enter the desired text. 

 

The LEFT magnetic switch changes the character.  Each LEFT switch activation moves forward or backward 
through the available characters.  Wait two seconds between switch activations and the direction reverses.    

 

The RIGHT magnetic switch saves the displayed character to memory. 

 

There are three methods of exiting… 

 

Save two SPACE characters in a row.

 

 

Configure the maximum number of characters (21).

 

 

Turn OFF power to the ITL40.

 

 
The custom message scroll can also be configured through a CAN message.  Contact Class 1 for details.

 

 

3.9.  Use the display reference mark 

 
 
The level the ITL40 shows may be difficult to distinguish at a distance for some 
viewers.  The ITL40 can be configured with a reference mark at the top of the 
display (single LED ON) which will help quickly determine level. 
 

 

Enter the password 

LLRR RRRR

 to turn the reference mark ON. 

 

Enter the password 

LLRR LLLL

 to turn the reference mark OFF.

 

 

The default for the reference mark is OFF.

 

 

 

Содержание Class 1 ITL 40

Страница 1: ...ISO 9001 CERTIFIED 607 NW 27th Ave Ocala FL 34475 Phone 352 629 5020 or 800 533 3569 Fax 352 629 2902 SUITABLE FOR EXTERNAL DISTRIBUTION Intelli Tank Level 40 OPERATION MANUAL...

Страница 2: ...n 10 3 3 7 Invalid calibration 10 3 3 8 Calibration incomplete 11 3 4 SELF TEST 11 3 5 SETTING THE DIM LED LEVEL 11 3 6 SHOW SOFTWARE VERSION DEVICE SETTINGS AND ERRORS 11 3 7 CONFIGURE THE COMMUNICAT...

Страница 3: ...STERS and 2 REMOTES 21 6 3 3 CAN method 1 MASTER and 2 REMOTES 22 6 3 4 CAN method 2 MASTERS and 2 REMOTES 22 6 3 5 Terminating resistor requirement CAN communication 23 6 4 COMMUNICATION COMPATIBILIT...

Страница 4: ...4 of 27 DATE 6 12 2019 PRODUCT GROUP ITL40 P N 118404 XX REV 1 30 PRODUCT Intelli Tank Level 40 BY AMS MANUAL P N 118253 PRINTED 6 12 19 1 Revision Log Rev Date Approved Changes 1 00 9 24 2008 AGK In...

Страница 5: ...04 123340 04 Green LEDs p n 118404 05 123340 05 Blue LEDs p n 118404 06 123340 06 2 Red 2 Yellow 2 Blue 2 Green rows of LEDs Labels C1 p n 117691 water blue p n 117692 foam red p n 117693 foam green...

Страница 6: ...3 1 LED indications The ITL40 display uses 8 rows of LEDs to show the unit status tank level indication section 3 1 2 and error indications section 3 1 3 3 1 1 Initial power ON indications When the I...

Страница 7: ...l 40 BY AMS MANUAL P N 118253 PRINTED 6 12 19 3 1 3 Error indications Condition Visual Condition Visual Invalid calibration NO DATA REMOTE is not receiving data from MASTER Incomplete calibration Pass...

Страница 8: ...mall o to indicate the location of the magnetic switch For best results the magnet should be positioned over the desired switch approximately 2 inches from the front of the display pushed directly to...

Страница 9: ...ection 3 1 3 on the next power cycle 3 3 1 1 Point Calibration 1 point calibration only calibrates the full point The empty calibration is always set to 0 55V approximately 1 5 inches of liquid 1 Make...

Страница 10: ...then activate the RIGHT switch The display will flash the top two LED rows and then begin scrolling the text SET 1 4 4 Fill the tank to the one quarter point and then activate the RIGHT switch The di...

Страница 11: ...ommunication wire test WIRE PASS Data communication lines good WIRE FAIL Data communication lines shorted or open If the self test password is used on a MASTER display all REMOTE displays will also pe...

Страница 12: ...CAN communication method is new for the ITL40 displays and is a more robust communication method This method requires two wires CAN high CAN low and approved J1939 CAN wiring and connectors There sho...

Страница 13: ...Q R S T U V W X Y Z SP 0 1 2 3 4 5 6 7 8 9 Enter the password LLLL LRLR and the display will show the first available character A Use the LEFT and RIGHT magnetic switches to enter the desired text Th...

Страница 14: ...causes the fluid to slosh producing significant fluctuation in the displayed tank level The ITL40 can counteract these conditions by averaging the rhythmic changes sloshing detected by the pressure s...

Страница 15: ...e feature has been enabled 3 11 2 Disabling the AutoFill output Disable the AutoFill feature by entering the password LRRL RLLR The display will scroll FILL OFF to indicate that the feature has been d...

Страница 16: ...n 3 7 3 LRRR LRRR Configure as Master display with CAN address 3 section 3 7 3 LRRR RLLR Configure as Master display with CAN address 4 section 3 7 3 LRRR LRLR Configure as Master display with CAN add...

Страница 17: ...k section 3 8 RRRL LLRR Configure AutoFill turn on for 3 8 Tank section 3 8 RRRL LRLL Configure AutoFill turn on for 1 2 Tank section 3 8 RRRL LRLR Configure AutoFill turn on for 5 8 Tank section 3 8...

Страница 18: ...18 of 27 DATE 6 12 2019 PRODUCT GROUP ITL40 P N 118404 XX REV 1 30 PRODUCT Intelli Tank Level 40 BY AMS MANUAL P N 118253 PRINTED 6 12 19 5 Installation 5 1 Cutout dimensions The display requires a c...

Страница 19: ...0 BY AMS MANUAL P N 118253 PRINTED 6 12 19 5 3 Label orientation Before mounting the display and adhering the label insure that the display is situated correctly TOP is UP Refer to the drawing for ori...

Страница 20: ...IELD DATA SAE J1939 CAN 2 0B 250Kbits s 4 DIM DISPLAY INPUT Dim display input positive polarity 5 Sensor REF OUTPUT pressure sensor supply 5VDC 6 Sensor SIGNAL INPUT pressure sensor signal 0 5VDC to 4...

Страница 21: ...The simplest system would be comprised of a single ITL40 MASTER display 6 3 1 1 wire method 1 MASTER and 2 REMOTES System configured with 1 wire communication method Make certain that the ground for...

Страница 22: ...communicating with 2 REMOTE displays configured with address 1 Two CAN terminating resistors p n DT06 3S P006 are required in the system one at each end of the CAN bus 6 3 4 CAN method 2 MASTERS and 2...

Страница 23: ...nating resistor p n DT06 3S P006 CAN 3 way Y connector p n DT04 3P P007 6 4 Communication compatibility with Class 1 products The ITL40 display is compatible with other Class 1 CAN and 1 wire products...

Страница 24: ...ise recalibrate or reset as REMOTE Outer two LED rows alternate flashing Invalid calibration Try to recalibrate If condition remains check if the sensor signal voltage pin C changes as tank level incr...

Страница 25: ...have changed No picture Check the pressure sensor for problems Recalibrate the display and take a voltage reading from the sensor pin 6 on the display s connector at each calibration point When the ca...

Страница 26: ...g flammable liquids where blanketing or smothering effect of water is of prime importance in extinguishing gasoline etc IP Ingress Protection IP 67 etc ITL Intelli Tank Level Class 1 s 4 and 5 light t...

Страница 27: ...to SAE J1113 specification for heavy duty trucks Transient voltage protected to SAE J1113 specification for heavy duty trucks Dimensions W x H x D in inches mm 3 185 80 90 x 5 125 130 17 x 2 150 54 6...

Страница 28: ...nated biphenyls PBB and polybrominated diphenyl ethers PBDE in electrical and electronic equipment Parts TOXIC AND HAZARDOUS SUBSTANCES OR ELEMENTS Pb Hg CrVI PBBs PBDEs Cd Base O O O O O O Box O O O...

Отзывы: