Page 3 of 19
S750
Air Tool
Specifications and
Air Line Requirements
Air Line Requirements
Air Line Pressure : 100 PSI Minimum, 150 PSI
Maximum
Consumption: 3-5 CFM
Line Size: ¼” I.D. Minimum
Connection: ¼” N.P.T.
Filter/Lubricator: Located in Air Supply in back of
Air Tool.
Lubricant: SAE 10 Wt. Non-Detergent Motor Oil
Safety Procedures
1. Familiarize yourself with operating procedures
before operating the S750 Air Tool.
2. Do no operate tool without cover in place.
3. Use only recommended BAND-IT preformed
clamps.
4. Do not exceed recommended pressure
settings. Excess pressure may cause sudden
clamp failure during application or result in an
unsafe clamp.
5. Always keep fingers clear of clamp during
application.
6. Disconnect air supply before servicing air tool.
7. Tool must be firmly mounted (see page 4)
8. Safety glasses or goggles should be worn
when applying clamps.