background image

16

17

Dehumidification, W3 (3rd Stage Heat) or AUX 

heat (for heat pumps).  If your home uses one of 

these options, follow these steps to set up your 

system:

1.  Press the 

 button on your 

 iDevices

®

 Thermostat.

2.  Use the   buttons to scroll to ‘Setup’  

 

and press the 

 button to select.

3.  Use the   buttons to scroll to ‘Relay’  

 

and press the 

 button to select.

4.  Set the ‘Type’ for your system configuration.

Set In-App Preferences

In your iDevices

®

 Connected app, select the 

Thermostat on the home screen. Tap the ‘Menu’ 

button in the upper left-hand corner. From 

here, you can edit the details of your iDevices

®  

Thermostat organize it into a ‘Room’ and ‘Zone’, 

set schedules and create ‘Scenes’. 

Testing Your System

1.  Set your iDevices

® 

 Thermostat to HEAT  

  mode. Adjust the temperature set point  

  above the ambient temperature in the room,  

  and verify that the heat turns on.

2.  Set your iDevices

® 

 Thermostat to COOL  

  mode (if outside temperature is above  

  50ºF). Adjust the temperature set point  

  below the ambient temperature in the room,  

  and verify that the cooling turns on.

3.  If your system has dual fuel sources (heat  

 

pump plus electric or fuel-fired emergency  

 

heat), set your iDevices

® 

 Thermostat  

 

to EMERGENCY HEAT mode. Adjust the  

 

temperature set point above the ambient  

 

temperature in the room and verify that the  

 

heat turns on.

4.  Note: If you have a heat pump or air

 

conditioner, the iDevices

®

 Thermostat is

 

designed to prevent damage to your  

 

compressor by waiting 5 minutes between  

 

restarts of your air conditioner or heat pump.  

 

If you are testing the operation of your air  

 

conditioner or heat pump, wait at least 5  

 

minutes after changing the temperature  

 

setting for the system to turn on.

Warnings And Safety Information

Do not short across terminals on the gas valve or at 

the heating or cooling system control board to test the 

thermostat installation. This could damage the thermostat 

and void the warranty.

Do not select COOL mode if the outside temperature is 

below 50ºF (10ºC). This could damage the cooling system.

Содержание HVAC

Страница 1: ...Welcome To INSTALLATION GUIDE...

Страница 2: ...ort iDevicesinc com Visit iDevicesinc com Support Please visit iDevicesinc com Compatibility to see if your HVAC system is compatible Contents Introduction 3 In The Box 4 Display 5 Before You Start 6...

Страница 3: ...Up 11 Temp Navigate Down 1 2 3 4 7 6 5 In The Box iDevices Thermostat Mounting Hardware Requires Home Wi Fi Network Free iDevices Connected App 24VAC Common Wire Compatible Mobile Device Visit iDevice...

Страница 4: ...licable building codes It should be installed in an area with good airflow Avoid areas behind doors near corners heating or cooling vents heat generating devices or direct sunlight Installation Overvi...

Страница 5: ...system O B This option selects the type of reversing valve for heat pump systems An O reversing valve is energized when cooling and a B reversing valve is energized when heating Most systems use an O...

Страница 6: ...t your existing system Using your old thermostat turn on the heating cooling functions if applicable to verify everything is functioning normally 3 If you have a heat pump system check the settings on...

Страница 7: ...the wall by gently wrapping them around a pen Remove the mounting plate from the wall 12 Line up the iDevices Thermostat mounting plate on the wall in the desired location Check that it is level and...

Страница 8: ...mode from the Settings Setup Connect menu Connecting To The App And Wi Fi Network 1 Download and launch the free iDevices Connected app on your mobile device 2 From the iDevices Connected app add the...

Страница 9: ...temperature is above 50 F Adjust the temperature set point below the ambient temperature in the room and verify that the cooling turns on 3 If your system has dual fuel sources heat pump plus electri...

Страница 10: ...t One Two or Three Stages G wire is not required for hot water baseboard or steam radiator systems If G wire is not connected for a warm air heating system Fan On mode will not be available Connect W2...

Страница 11: ...ages and Cool One or Two Stages Connect Y2 wire 2nd Stage Cooling is optional if available Connect W2 wire 2nd Stage Heating is optional if available The HUM relay can be used for Humidification Dehum...

Страница 12: ...for more information Dotted lines indicate an optional wire Troubleshooting Support For a full list of troubleshooting articles visit iDevicesinc com Support Call or email the iDevices Customer Exper...