Optional DC Power In 

0v 

DC Power Ground 

+12 

DC Power Input

Requirements:

10 – 16 Vdc

350 mA 

(50 mA internal)

  1

1

/0

5

/1

9

WIRING REFERENCE 

EM-40-1HA

a

 

Relay Output 

Nc 

Normally Closed 

Common 

No 

Normally Open 

Relay Contact: 

DC: 

30 Vdc @ 1Adc

Digital Contact Inputs 

R1-R6 

Ground 

In1-

In6 

Non-Supervised or 
Supervised Inputs 1-6 

RS-485 Reader (2 Wire) 

+12

Power Output 

A

Data A Input 

B

Data B Input 

0v

Ground 

RS-485 Reader (4 Wire)

 

+12

Power Output 

T-

Transmit Inverted signal

T+ 

Transmit non-inverted signal

0v 

Ground

R-

Receive inverted signal

R+ 

Receive non-inverted signal

 

Power Output using DC: 

8.5 – 16 Vdc

350 mA Max. Current

Reset Button 

Press and hold this button for 

10 seconds to reset the 

configuration back to default.

 

50-40-

485

NOTE: 

As long as the total current of 

the  reader  plus  a  door  strike 

DOES 

NOT  EXCEED  300mA

,  you  may 

power  the  door  strike  using  the 
power  out  and  ground  from  the 
Reader Input terminal block.

 

 

 

 

 

 

 

 

 

 

 

Black 

1N4005 

Diode 

Red 