ATEX Certification
Equipment or protected system intended for use in potentially explosive atmosphere directive 94/9/EC.
Compliance with the essential health and safety Requirements has been assured by compliance with the
following standards: EN 60079-0:2012, EN 60079-11:2012
IECEx Certification
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the
identified documents, was found to comply with the following standards: IEC 60079-0:2011, IEC 60079-
11:2011
Special conditions for safe use – ATEX and IECEx
WARNING
-
Electrostatic Hazard
:
Do not install in locations with increased electrostatic charge such as close to ventilations
systems or electric drives.
WARNING
-
Electrostatic Hazard
: Clean plastic Tag surface only with a damp cloth. Do
not use solvents.
WARNING
-
This product should be installed by personnel trained in installation of
equipment in Hazardous Locations and meet the representative country’s National Electrical
Code.
EPS 14 ATEX 1 668 X
II 1 G
Ex ia IIC T4
-20°C ≤ Ta ≤ +70°C
IECEx EPS 14.0032X
Type of Protection
Ex i
Marking
Ex ia I
Ex ia IIC T4