Installation and Operation Manual
Page 10 of 11
5
Technical Data
Operating Data
Operating frequency ILR-RFID
868 MHz (EU) or 920 MHz (NA), further frequencies on request
Maximum transmission power
0.75mW (EU / NA)
Compatibility
i-PORT M 350, i-CARD CF-350
Standards/Certification FCC
Part 15 (US), ETSI EN 300 220 (EU)
Communication Data Long-Range RFID (ILR, Response Technology)
Multiple tag handling
Up to 2,000 tags in the read zone
Read/write range response mode
Up to 250 m (800 feet), free air*
Data rate response
19.2 to 115.2 kbits/s
Communication Data Long-Range RFID (ILR, Beacon Technology)
Read range broadcast
Up to 500 m (1600 feet) free air*
Operation mode
Transmits marker information in at regular intervals
Repetition rate (ping rate)
0,5 – 300 seconds, adjustable in steps of 0,5 seconds
Data rate broadcast 115.2
kbits/s
* The communication range depends on the antenna type, the antenna cable runs and the environmental conditions.
Communication Data Inductive Loop (Marker)
Read range
Up to several meters
Operating frequency
125 kHz (world-wide approved)
Operation mode
Receives marker ID number and transmits marker information several times
Electrical
Power source
Lithium battery (not replaceable)
Battery monitoring
Yes
Temperature Logging
Number of samples
10,000
Logging interval
User definable in intervals from 1 to 255 min
Measuring interval
User definable in intervals from 0 s to 255 min
Metering range
–40
°C to +85
°C (–40
°F to +176
ºF) with std. internal sensor
–80
°C to 110
°C (–112
°F to +230
ºF) with std. external sensor
Other metering ranges are available on request
Resolution 0.1
°C (0.2
°F)
Accuracy ±0.5
°C (1
°F) from -20
°C up to +50
°C,
±1
°C (2
°F) in the remaining temperature range
Data
Data retention
> 10 years without power
Write cycles
100,000 writes to a tag
Memory size
10,000 Bytes user definable
Identification code
48 bit fixed ID
Environmental Conditions
Operating temperature
–40
°C to +85
°C (–40
ºF to +185
ºF)
Humidity
10 % to 95 % relative humidity @ 30
°C
Shock
50 G, 3 times DIN IEC 68-2-27
Multiple drops to concrete from 1 m (3 ft)
Vibration
3 G, 20 sine wave cycles, 5 Hz to 150 Hz, DIN IEC 68-2-6
5 G, noise 5 Hz to 1000 Hz, 30 minutes, DIN IEC 68-2-64
Physical
Dimensions
131 mm × 28 mm × 21 mm (5.2 in. × 1.1 in. × 0.85 in.)
Enclosure Plastic
(Qinnacryl)
Weight
50 g (1.75 ounces)
Enclosure rating
IP 65