background image

 
 
Installation and Operation Manual 

Page 10 of 11 

5

 

Technical Data 

 

Operating Data 

Operating frequency ILR-RFID 

868 MHz (EU) or 920 MHz (NA), further frequencies on request 

Maximum transmission power 

0.75mW (EU / NA) 

Compatibility 

i-PORT M 350, i-CARD CF-350 

Standards/Certification FCC 

Part 15 (US), ETSI EN 300 220 (EU) 

 

Communication Data Long-Range RFID (ILR, Response Technology) 

Multiple tag handling 

Up to 2,000 tags in the read zone 

Read/write range response mode 

Up to 250 m (800 feet), free air* 

Data rate response 

19.2 to 115.2 kbits/s 

 
Communication Data Long-Range RFID (ILR, Beacon Technology) 

Read range broadcast 

Up to 500 m (1600 feet) free air* 

Operation mode 

Transmits marker information in at regular intervals 

Repetition rate (ping rate) 

0,5 – 300 seconds, adjustable in steps of 0,5 seconds 

Data rate broadcast 115.2 

kbits/s 

  

* The communication range depends on the antenna type, the antenna cable runs and the environmental conditions. 

 
Communication Data Inductive Loop (Marker) 

Read range 

Up to several meters 

Operating frequency 

125 kHz (world-wide approved) 

Operation mode 

Receives marker ID number and transmits marker information several times 

 
Electrical 

Power source 

Lithium battery (not replaceable) 

Battery monitoring 

Yes 

 

Temperature Logging 

Number of samples 

10,000 

Logging interval 

User definable in intervals from 1 to 255 min 

Measuring interval 

User definable in intervals from 0 s to 255 min 

Metering range 

–40

 

°C to +85

 

°C (–40

 

°F to +176

 

ºF) with std. internal sensor 

–80

 

°C to 110

 

°C (–112

 

°F to +230

 

ºF) with std. external sensor  

 

Other metering ranges are available on request 

Resolution 0.1

 

°C (0.2

 

°F) 

Accuracy ±0.5

 

°C (1

 

°F) from -20

 

°C up to +50

 

°C, 

±1

 

°C (2

 

°F) in the remaining temperature range 

Data 

Data retention 

> 10 years without power 

Write cycles 

100,000 writes to a tag  

Memory size 

10,000 Bytes user definable 

Identification code 

48 bit fixed ID 

 

Environmental Conditions 

Operating temperature 

–40

 

°C to +85

 

°C (–40

 

ºF to +185

 

ºF) 

Humidity 

10 % to 95 % relative humidity @ 30

 

°C 

Shock 

50 G, 3 times DIN IEC 68-2-27 
Multiple drops to concrete from 1 m (3 ft)  

Vibration 

3 G, 20 sine wave cycles, 5 Hz to 150 Hz, DIN IEC 68-2-6 

  

5 G, noise 5 Hz to 1000 Hz, 30 minutes, DIN IEC 68-2-64 

 

Physical  

Dimensions 

131 mm × 28 mm × 21 mm (5.2 in. × 1.1 in. × 0.85 in.) 

Enclosure Plastic 

(Qinnacryl) 

Weight 

50 g (1.75 ounces) 

Enclosure rating 

IP 65 

 

 
 
 
 

Содержание ILR 350 Series

Страница 1: ...ILR 350 Series Installation and Operation Manual for Tag Models i Q350 i Q350T i Q350L i Q350TL...

Страница 2: ...tation damages resulting from use of or reliance on information presented herein or loss of profits or revenues or costs of replacement goods even if informed in advance of the possibility of such dam...

Страница 3: ...ipment European Notification according R TTE Directive This equipment complies to Art 6 4 of R TTE Directive 1999 5 EC It is tested for compliance with the following standards ETSI EN 300 220 ETSI EN...

Страница 4: ...D PROCEDURE 5 1 3 SCOPE OF THIS DOCUMENT 5 1 4 RESPONSIBILITY 5 1 5 ASSOCIATED DOCUMENTS 5 1 6 SCOPE OF DELIVERY VISUAL INSPECTION 5 2 SAFETY PRECAUTIONS 6 3 TAG MOUNTING TECHNIQUES 7 3 1 RIVETS 7 3 2...

Страница 5: ...s the user s manual of this tag models i Q350 i Q350T i Q350L i Q350TL This document is intended only for mechanical installation rsp everyday use 1 4 Responsibility IDENTEC SOLUTIONS is not responsib...

Страница 6: ...temperatures below 0 C 32 F tags can be iced In this case wait a while until tags are warmed up or use gloves Battery Inside All tags contain a battery That is the reason for the following instructio...

Страница 7: ...a chance this might occur it is better to use a blind rivet with a large head Refer to UN9924 or insert a 3 16 washer This has the effect of distributing the pressure over a larger surface area durin...

Страница 8: ...of at least 10 C 50 F must be maintained during mounting to prevent the casing from cracking 5 Depending on the type and strength category of the 10 screw used the maximum tightening torque must be b...

Страница 9: ...soon as possible A Brief Checklist Are all housings intact Are all cables intact Are all connectors intact Are all connectors securely fastened Are all screws still tight Is there suddenly a malfunct...

Страница 10: ...e approved Operation mode Receives marker ID number and transmits marker information several times Electrical Power source Lithium battery not replaceable Battery monitoring Yes Temperature Logging Nu...

Страница 11: ...i Q350TL Tag Manual Page 11 of 11 Dimensional Drawing All dimensions in mm External cable to temperature sensor models i Q350T i Q350TL not shown...

Отзывы: