background image

 

 
MSO Fingerprint scanners Installation Guide 
Error! Use the Home tab to apply Titre 1 to the text that you want to appear here. 

 

 

 

 

 

2018_2000039830 
October 2021 

This document and the information therein are the property of IDEMIA. They must not be copied 
or communicated to a third party without the prior  authorization of IDEMIA 

26 

 

7.2.4  Identify performances 

The identify process compare the search fingerprint to all the records of the database. 

The identify process compare first the search fingerprint to the 1

st

 fingerprint (fingerprint 

#1) of each database record. If a match is found, the comparison process stops, else, the 
identify process  compare  the  search  fingerprint to  all  2nd fingerprint  (fingerprint #2)  of 
each database record. 

It means that the identification process is faster when the user place on the sensor, a finger 
which is recorded as the 1st fingerprint of the user’s record. It also means that the time 
required to reject a fingerprint (No Hit) is higher than the time required to match with the 
1st fingerprint of a record. 

 

Number of records 

Hit fingerprint # 1 

Hit fingerprint # 2 

No Hit 

100 

≤ 1 s 

≤ 1.5 s 

≤ 1.5 s 

500 

≤ 1.1 s 

≤ 1.5 s 

≤ 1.5 s 

2000 

≤ 1.5 s 

≤ 2 s 

≤ 2 s 

3000 

≤ 2 s 

≤ 2.5 s 

≤ 2.5 s 

5000 

≤ 2.5 s 

≤ 3 s 

≤ 3 s 

Table 13: Identify performances 

Please not that: 

 

The  measure  starts  with  finger  valid  placement  on  the  sensor  and  stops  with  result 
returned to the host system. 

 

the  time  value  is  intended  for  typical  fingerprints  :  more  characteristic  points  per 
fingerprint (such as for a thumb fingerprint) means more time. 

 

Add 1 second to ‘no hit’ time when ‘advanced matching’ is used (please refer to the 
definition of ID_Matching_Strategy optional ILV in [R2] and [R4] documents)  

 

The time  value  can  be multiplied  by  2  when  ‘not  oriented  matching’  is  used  (please 
refer to the definition of value 2 for Sensor_Window_Position ILV definition in in [R2] 
and [R4] documents). 

 

Содержание MSO300

Страница 1: ...MSO Fingerprint scanners Installation Guide October 20212 2018_2000039830 Version 2 24 MSO300 MSO301 MSO1300 MSO1350 MSO Fingerprint scanners Installation Guide...

Страница 2: ...y purpose without the express written permission of IDEMIA The software described in this document is supplied under a license agreement or nondisclosure agreement It is against the law to copy the so...

Страница 3: ...uly 2004 Add MMI description for MSO350 Add IDENTLITE license reference 1 9 December 2004 Precisions with the LEDS states Add MSO CBM 2 0 April 2005 Update of hotline phone number 2 1 July 2005 Added...

Страница 4: ...15 March 2013 Update registered office address 2 16 October 2013 Update MSO1300 and MSO1350 pictures from 2014 2 17 May 2015 Update footer legal text 2 18 Feb 2018 Update Company s logo 2 19 November...

Страница 5: ...1 1 Dimensions and Weight 15 4 1 2 Temperature range and humidity 15 4 1 3 IP rating 15 4 2 General description 16 4 2 1 Top view 16 4 2 2 Bottom view 16 4 3 MSO301 devices specificities 17 4 4 Speci...

Страница 6: ...ne Interface 28 8 2 1 Description 28 8 2 2 Biometric terminal status 28 8 2 3 Biometric request status 28 8 2 4 Smart card reader status MSO1350 28 9 Secure MSO getting started 29 9 1 Description 29 9...

Страница 7: ...rization of IDEMIA 7 List of figures Figure 1 MSO300 3D View 15 Figure 2 MSO3xx Top View 16 Figure 3 MSO3xx Bottom View 16 Figure 4 MSO1300 18 Figure 5 MSO1300 3D view 19 Figure 6 MSO1300 Bottom view...

Страница 8: ...MSO 300 devices IP rating 16 Table 5 MSO 1300 devices weight and sizes 18 Table 6 MSO 1300 devices temperature and humidity range 18 Table 7 MSO 1300 devices IP rating 19 Table 8 MSO 1350 devices wei...

Страница 9: ...more than 20 years of experience in the field of biometric identification and the processing of literally millions of individual fingerprint identification records We believe you will find the MSO te...

Страница 10: ...nly The MSO terminals must be placed on a flat clear surface where it will not be at risk of coming in contact with fluids 2 2 MSO Hardware Platform Compatibility The MSO USB devices are compatible wi...

Страница 11: ...he USB connector of the MSO USB device to a USB port of the PC Wait for USB enumeration process usually not more than a few seconds Then the device is ready for use for example with the sample applica...

Страница 12: ...tab to apply Titre 1 to the text that you want to appear here 2018_2000039830 October 2021 This document and the information therein are the property of IDEMIA They must not be copied or communicated...

Страница 13: ...processed as a Communication Device Class CDC in accordance with the USB Device Class Specifications version 2 0 available from the www usb org web site in developers documents section The MSO devices...

Страница 14: ...ion therein are the property of IDEMIA They must not be copied or communicated to a third party without the prior authorization of IDEMIA 14 3 MSO USB driver installation 3 1 MSO USB driver setup Get...

Страница 15: ...MSO3xx 3xx1 are dedicated to be connected to an USB port which supplies the required power Figure 1 MSO300 3D View 4 1 1 Dimensions and Weight Device Dimensions L x w x h Weight Sensor MSO3xx 80 x 92...

Страница 16: ...n of IDEMIA 16 MSO30x which integrates a MSO xxx OEM IP53 rated sensing window Table 4 MSO 300 devices IP rating The table above defines also the maximum value of the IP ingress protection rating whic...

Страница 17: ...st with their fingers Use compressed gas for electronic devices to avoid electrostatic discharges In order to eliminate organic marks a weekly cleaning is required In this case using a rag moistened w...

Страница 18: ...cs The MSO1300 device is dedicated to be connected to an USB port which supplies the required power Figure 4 MSO1300 5 1 1 Dimensions and Weight Device Dimensions L x w x h Weight Sensor MSO1300 68 7...

Страница 19: ...he prior authorization of IDEMIA 19 MSO1300 which integrates a CBM OEM IP65 rated sensing window Table 7 MSO 1300 devices IP rating The table above defines also the maximum value of the IP ingress pro...

Страница 20: ...communicated to a third party without the prior authorization of IDEMIA 20 6 MSO1350 6 1 Physical Characteristics The MSO1350 includes a smart card reader and is dedicated to be connected to an USB p...

Страница 21: ...2 Temperature range and humidity Device Temperature range Humidity Operating Storage Operating Storage MSO1350 0 C to 50 C 20 C to 70 C 10 RH 85 RH 95 Table 9 MSO 1350 devices temperature and humidit...

Страница 22: ...nformation therein are the property of IDEMIA They must not be copied or communicated to a third party without the prior authorization of IDEMIA 22 6 2 General description 6 2 1 Top view and Side view...

Страница 23: ...IA 23 6 2 3 Smart Card Reader characteristics MSO1350 device is equipped with a smartcard reader that complies with ISO 7816 1 2 3 PC SC protocol CCID over USB2 protocol CPU based cards with T 0 and o...

Страница 24: ...authorization of IDEMIA 24 7 MSO device Technical Characteristics 7 1 Electrical characteristics 7 1 1 USB connection All USB MSO devices The MSO devices comply with the USB 1 1 standard They operate...

Страница 25: ...records when redundant template check is off Number of records 500 3000 5000 USB 17s 100s 172s Table 12 Not encrypted Database fulfill time 7 2 3 Verify performances The verify process compare the sea...

Страница 26: ...finger which is recorded as the 1st fingerprint of the user s record It also means that the time required to reject a fingerprint No Hit is higher than the time required to match with the 1st fingerp...

Страница 27: ...us The tables below describe the meaning of the light signals 8 1 2 Biometric terminal status Status Sensor Lower LED Upper LED Suspend low power mode Off Off Off Stand By wait for a request Off Flash...

Страница 28: ...nal status Status Sensor Suspend low power mode Off Stand By wait for a request from host system Off Maintenance State such as firmware update in progress Blinking Personalization State secure MSO Bli...

Страница 29: ...ation Install MKMS by double clicking on MKMS installer version exe After installation start the MKMS application in C IDEMIA MSO Key Management System Select the Root key generation action in the Ini...

Страница 30: ...correctly 10 2 Cable bend radius When the cable need to be bended please to figure below it is recommended to have a bend radius value higher than 1 2 cm Figure 11 MSO cable radius recommendation 10 3...

Страница 31: ...scharge and depending on the environment synthetic carpet should be avoided in areas where the MSO terminal has been installed 10 8 Cleaning precautions It is recommended to clean the sensor when it i...

Страница 32: ...the information therein are the property of IDEMIA They must not be copied or communicated to a third party without the prior authorization of IDEMIA 32 Any other practices Scratch materials bleach c...

Страница 33: ...re certified for many countries including Morocco For declarations of conformity and details please see https www biometric terminals com 11 2 MSO1300 MSO 1300 products are traced through Model Number...

Страница 34: ...ied or communicated to a third party without the prior authorization of IDEMIA 34 12 Bibliography Title Description EDM reference R1 MSO Overview General information about MSO product family 2018_2000...

Страница 35: ...formation available on website https biometricdevices idemia com s USA Canada Email support bioterminals us idemia com Phone 1 888 940 7477 LATAM Latin America Email support bioterminals us idemia com...

Страница 36: ...sed when the finger is optimally positioned Common non optimal finger positioning is illustrated below followed by an illustration of best finger placement Fingerprint Placement Fingerprint Orientatio...

Страница 37: ...tab to apply Titre 1 to the text that you want to appear here 2018_2000039830 October 2021 This document and the information therein are the property of IDEMIA They must not be copied or communicated...

Страница 38: ...Copyright 2020 IDEMIA Registered Office 2 place Samuel de Champlain 92400 Courbevoie France www idemia com...

Отзывы: