MorphoWave
TM
OEM
Annex 1 : Maintenance
2015_2000009096 V6
January 2019
IDEMIA
D
OCUMENT
–
R
EPRODUCTION AND
D
ISCLOSURE
F
ORBIDDEN
83
Cleaning precautions
The use of a dry cloth is recommended to clean the terminal, especially the biometric
sensor. Acid liquids, alcohol or abrasive materials are prohibited.
Biometric sensor
Clean the glass every day to optimize performances of the product especially when
there is heavy dust deposit on the capture window.
Use a dry cloth to clean the terminal and the sensor. The use of acid liquids, alcohol
or abrasive materials is prohibited.
Use a dry air spray to remove the dust out of the sensor glass. Power supply
MA SIGMA family
DC power
supply
12V – 24V
(-15% / +10%)
DC power
supply
connection
Terminal block
Power
supply by
POE
IEEE802.3af
compliant
POE power
supply
connection
Only RJ45 connector
Ethernet communication
MA SIGMA family
Only RJ45 connector
RS485/RS422 communication
MA SIGMA family
Half duplex
Full duplex
(slave and master mode)