background image

IDEMIA DOCUMENT 

– REPRODUCTION AND DISCLOSURE PROHIBITED  

Wiring Overview

10

Power supply from electrical source shall be switched off before starting the installation.

Before proceeding, make sure that the person in charge of installation and connections, is properly connected to 
earth, in order to prevent Electrostatic Discharges (ESD).

All connections of the terminal are of SELV (Safety Electrical Low Voltage) type.

St

ep 

tw

w

iring

Backup of the Date/Time of the terminal:

the volatile settings (such as date/time) of the terminal are protected against 

power failure, by a dedicated component during a least 24 hours (at 25

o

C) without external power supply. 

RJ-45 : Ethernet & PoE

1

ETH TX+

Orange / White

2

ETH TX-

Orange

3

ETH RX+

Green / White

4

ETH VPORT+

Blue

5

ETH VPORT+

Blue / White

6

ETH RX-

Green

7

ETH VPORT-

Brown / White

8

ETH VPORT-

Brown

Shell ETH GND

Drain wire (no color)

Wiegand IN & Wiegand OUT

25

WIEGAND_LEDOUT1

Blue

28

WIEGAND_LEDOUT2

Blue / Red

23

WIEGAND_IN1

White / Red

24

WIEGAND_OUT0

Green

26

WIEGAND_OUT1

White

21

WIEGAND_IN0

Green / Red

27

WIEGAND_GND

Black / Red

RS-422 and 485

7

RS485_RX_A

Blue / Black

8

RS485_TX_Z

Green / White

9

RS485_RX_B

Blue / White

10

RS485_TX_Y

Green / Black

11

RS485_GND

Black / Red

Power supply & Tamper switch

13

RLY_NC

Orange / White

14

RLY_NO

Yellow / White

12

RLY_COM

Grey / White

5

SWITCH_PIN1

Light Blue

6

SWITCH_PIN2

Pink

1,3

Power + 12V

Red

2,4

Power GND

Black

RJ45

GPIO

19

GPI2

Orange / Black

20

GPO2

Yellow / Red

17

GPI1

Orange / Red

18

GPO1

Yellow / Red

15

GPI0

Orange

16

GPO0

Yellow

22

GPIO_GND

Black / Red

IDEMIA  - 2018_2000035854 

– V1

Pin numbers shown in this document correspond to the 
internal connector pinout in the product. The connector 
attached to the cable is for test only and should be removed 
for installation.

Содержание MorphoWave Compact

Страница 1: ...AND DISCLOSURE PROHIBITED MorphoWave Compact Quick User Guide 2018_2000035854 V1 All descriptions illustrations and specifications in this brochure should be considered approximate and may relate to o...

Страница 2: ...LOSURE PROHIBITED Table of Contents IDEMIA 2018_2000035854 V1 2 Color Step Content One Overview Two Wiring Three Communication Four SDAC Single Door Access Control Five Administration Six Software Sev...

Страница 3: ...d 10 meters This system must be installed in accordance with the National Electrical Code NFPA 70 and the local authority having jurisdiction This product is intended to be installed with a power supp...

Страница 4: ...swipe through the active volume without contact IDEMIA False finger detection algorithms Simple and ergonomic man machine interface Contactless card reader MIFARE Classic MIFARE Plus DESFire HID Icla...

Страница 5: ...MorphoWave Compact Checklist 5 Step one overview QTY ITEM 1 MorphoWave Compact terminal 1 Wall Mounting Plate 1 Documentation package Electronic documentation is provided in Adobe Acrobat format PDF...

Страница 6: ...al s User ID is listed in the Controller authorized user List Control of the latch is made through a dry contact An Alarm 3rd party product The terminal sends a message to the Access Controller to act...

Страница 7: ...e terminal checks user s access rights using a biometric check If the result of the check is successful access granted a message is sent to the Central Access Controller for additional access rights c...

Страница 8: ...bled Triggering events are selected by the remote application Biometric check if enabled The user s captured fingerprints are matched against all fingerprints in the terminal database The user s captu...

Страница 9: ...e or combustible gases or materials The terminal is not designed to be intrinsically safe The terminal should be installed in controlled lighting conditions Avoid exposure of the biometric sensor to d...

Страница 10: ...White 6 ETH RX Green 7 ETH VPORT Brown White 8 ETH VPORT Brown Shell ETH GND Drain wire no color Wiegand IN Wiegand OUT 25 WIEGAND_LEDOUT1 Blue 28 WIEGAND_LEDOUT2 Blue Red 23 WIEGAND_IN1 White Red 24...

Страница 11: ...y UPS with built in surge protection is recommended WARNING Under powering may cause memory and data corruption over powering may cause hardware damage Both of these situations will void the warranty...

Страница 12: ...uld be run in a daisy chain configuration i e converter position 1 position 2 position 3 etc Use CAT 5 UTP or better cable shielded recommended with a characteristic impedance of 120 ohms AWG 24 shoul...

Страница 13: ...onverter terminal Use CAT 5 UTP or better cable shielded recommended with a impedance of 120 AWG 24 should be the minimum wire gauge used Choose one twisted pair of conductors to use for RS485_TX_Y TX...

Страница 14: ...ndards WEP Open WPA and WPA2 are supported Use a category 6 shielding cable 120 Ohms or better It is strongly recommended to insert a repeater unit every 90 m Static mode is enabled by default on Morp...

Страница 15: ...WIEGAND_OUT1 White wire Pin 26 to ACP Data 1 Connect WIEGAND_GND Black Read wire Pin 27 to ACP reader common 0vDC For 18 AWG the maximum cable distance is 500 ft 150m for 20 AWG the maximum is 300 ft...

Страница 16: ...k The Wiegand port also supports the Clock Data protocol The wiring is described below Example Format Information Type Standard 26 bit Alt Site Code and Fail Site Code Range 0 255 Template ID Number R...

Страница 17: ...mple with Push Button Step four SDAC Power supply from electrical source shall be switched off before starting the installation IDEMIA 2018_2000035854 V1 13 RLY_NC Orange White 14 RLY_NO Yellow White...

Страница 18: ...e used The internal relay is designed for 100 000 cycles If more cycles are needed an external relay driven by GPO must be used Step four SDAC IDEMIA 2018_2000035854 V1 13 RLY_NC Orange White 14 RLY_N...

Страница 19: ...einitialize terminal main settings Local Administration First Boot Assistant 19 Main settings managed by FBA Date Time Time Zone Settings Trigger Event select event s to be processed as an access requ...

Страница 20: ...t is highly recommended to change the devices default password to a custom password Exit or Go Home Validation or confirmation Cancel or refuse Back and Cancel User management Terminal security Multim...

Страница 21: ...ing a dedicated Windows application MorphoBioToolBox Please note that this application has an embedded User Guide Help menu North and South America E mail support bioterminals idemia com with your nam...

Страница 22: ...N AND DISCLOSURE PROHIBITED MorphoWave Compact Series terminals are fully compatible with MorphoManager application version 12 or higher Software for Terminal Remote Administration IDEMIA 2018_2000035...

Страница 23: ...creating a user RF card with the user s reference data Enrolment gathering user s data listed User s first name and last name User s fingerprints for biometric check User s administration rights none...

Страница 24: ...IDEMIA DOCUMENT REPRODUCTION AND DISCLOSURE PROHIBITED Local Enrollment Process 2 2 IDEMIA 2018_2000035854 V1 24 Step seven capture basics NB To complete enrollment two waves are required...

Страница 25: ...Insert your hand flat palm down from the front of the scanner 2 Slightly spread apart your fingers 3 Place your hand between the cover and the optical sensor 4 Position your fingertips according to th...

Страница 26: ...ce your fingers tightly together 5 Do not place 2 hands inside 6 Do not place your hand on the cover 7 Do not touch the cover 8 Do not place your hand on the optical sensor 9 Do not place your hand on...

Страница 27: ...ID and starts the authentication process as defined by the terminal settings Contactless Card Position PIN input IDEMIA 2018_2000035854 V1 27 Contactless Card Position Input PIN When defined by termin...

Страница 28: ...is provided by the user through a specific screen displayed during identification or authentication process The new screen contains 4 dedicated function keys Entry Exit Beginning of a task Ending of...

Страница 29: ...cal database and at least after significant changes in the database add remove or modification of user s records on a external support such a mass storage key Date Time synchronization The MorphoWave...

Страница 30: ...Ref TBD This document contains the full description of all the terminal configuration parameters Documents for the developer MorphoWave Compact Host System Interface Specification Ref TBD This documen...

Страница 31: ...ave Compact Documents in the subject line Other countries please visit our web site www biometric terminals com To get your log in and password please contact your sales representative Copyright 2018...

Отзывы: