background image

 

 

 

8/11

CETE | Global R&D 

November 2017 | V1 

 

TECHNICAL CHARACTERISTICS  

 
Device Configuration 

MorphoTop Slim:     Slap Finger Print scanner (4/4/2), at 500 ppi IQS Appendix F certified, with VERIF 
license 

MorphoTop Slim R: Rolled Finger Print acquisition added, with ROLLED license 

 
Device Option (license containers) 

TOP-SLIM_MORPHOPAK

: to use activeX MorphoPAK for camera acquisition 

TOP-SLIM_CLASSIF

: Classification license 

TOP-SLIM_WSQ

: WSQ license for fingerprint image compression algorithm export 

TOP-SLIM_BCL

: Basic Compression Library license 

 
Man Machine Interface 

Two-colored LEDs & Buzzer 

Acquisition area 3’’x3.2’’ 

 
Size and weight 

Volume (L*W*H)   

= 14,5 x 13 x 2,6 cm

(5.7x5.1x1”) 

Weight    

 

= 0.4 Kg

 

 

   

Power consumption 

Operating (acquisition)    

Typical: Vbus = 5.0V, I < 600 mA => P< 3 W 

Idle (backlight switched off) 

Typical: Vbus = 5.0V, I = 410 mA => P= 2 W 

Suspend (USB link closed) 

I < 2,5 mA 

 
 
 
 

 

OPERATING CONDITIONS 

Operating 

Temperature: 0°C to +50°C. 

Relative Humidity:10%<RH<80%. 

Storage  

-40°C to +70°C.  

RH < 90%. 

Light 

We  recommend  the  MorphoTop  Slim  installation  within  controlled  lighting 
conditions  (300-1500  Lux).  Avoid  direct  exposure  of  sensor  to  sunlight  or 
intensive UV lights. Both may degrade the performances of the sensor on a 
long time period (even when device not powered). 

Ground connection 

Make  sure  that  the  ground  connection  of  your  computer  is  correctly  done 
(connected to earth), otherwise terminal might be sensible to electric noise 

Содержание MorphoTop Slim

Страница 1: ...CETE Global R D November 2017 V1 MorphoTop Slim Installation guide...

Страница 2: ...tion 4 Caution 4 USA information 4 Caution 4 GENERAL DESCRIPTION 5 RECOMMENDED DEVICE INSTALLATION 6 TECHNICAL CHARACTERISTICS 8 Device Configuration 8 Device Option license containers 8 Man Machine I...

Страница 3: ...hoTop Slim we recommend that you read this Installation Guide thoroughly RECOMMENDATIONS General precautions Do not put sharp hard object such as but not limited to screw driver pen USB connector on t...

Страница 4: ...ay cause interference In this case the user is encouraged to try to correct the interference with appropriated measures USA information This device complies with part 15 of the FCC Rules Operation is...

Страница 5: ...ation for USB2 Acquisition surface Acquisition type indicators 2 mounting holes for M3 screw Acquisition Status indicators Orange means harder pression on related finger is requested USB trapdoor to b...

Страница 6: ...NDED DEVICE INSTALLATION To optimize the ergonomic of Thumb acquisition it is advised to set up the product a bit over the table and fixed on the table thanks to the 2 mounting holes defined just befo...

Страница 7: ...Use two M3 screws to maintain the product to the table Choose a screw length table thickness 3 to 5 5mm Fix them gently without exceeding max force of 0 9 Nm and with M3 washers 1 1 mm thickness 0 1 m...

Страница 8: ...3 x3 2 Size and weight Volume L W H 14 5 x 13 x 2 6 cm3 5 7x5 1x1 Weight 0 4 Kg Power consumption Operating acquisition Typical Vbus 5 0V I 600 mA P 3 W Idle backlight switched off Typical Vbus 5 0V I...

Страница 9: ...ugged on the same controller especially high load devices such as hard disk or webcam or another MorphoTOP device It is highly recommended to plug MorphoTop Slim on a USB3 port USB2 port could be not...

Страница 10: ...TE Global R D November 2017 V1 Then you will be able to count USB controller on your computer It is highly recommended to have at least 2 controllers 1 for MorphoTop Slim 1 for other devices behind a...

Страница 11: ...biometric terminals com Produced by IDEMIA Identity Security France Registered office Adresse 11 boulevard Galli ni 92130 Issy les Moulineaux FRANCE Support For Products sold by other Business Units p...

Отзывы: