IDEMIA DOCUMENT
– REPRODUCTION AND DISCLOSURE PROHIBITED
Wiring Overview
IDEMIA - 2017_2000024419
– V4
9
Power supply from electrical source shall be switched off before starting the installation.
Before proceeding, make sure that the person in charge of installation and connections, is properly connected to
earth, in order to prevent Electrostatic Discharges (ESD).
All connections of the terminal are of SELV (Safety Electrical Low Voltage) type.
St
ep
tw
o
:
w
iring
Backup of the Date/Time of the terminal:
the volatile settings (such as date/time) of the terminal are protected against
power failure, by a dedicated component during a least 24 hours (at 25
o
C) without external power supply.
RJ-45 : Ethernet & PoE
1
ETH TX+
Orange / White
2
ETH TX-
Orange
3
ETH RX+
Green / White
4
ETH VPORT+
Blue
5
ETH VPORT+
Blue / White
6
ETH RX-
Green
7
ETH VPORT-
Brown / White
8
ETH VPORT-
Brown
Shell ETH GND
Drain wire (no color)
Wiegand IN & Wiegand OUT
1
WIEGAND_LEDOUT1
Blue
2
WIEGAND_LEDOUT2
Blue / Red
3
WIEGAND_IN1
White / Red
4
WIEGAND_OUT0
Green
5
WIEGAND_OUT1
White
6
WIEGAND_IN0
Green / Red
8
WIEGAND_GND
Black / Red
RS-422 and 485
7
RS422/485_GND
Black / Red
9
R
Blue / Black
10
RS422/485_TX-
Green / White
11
RS422_RX-
Blue / White
12
RS422/
Green / Black
Power supply & Tamper switch
19
RELAY_NC
Orange / White
21
RELAY_NO
Yellow / White
22
RELAY_COM
Grey / White
23
SWITCH_PIN1
Light Blue
24
SWITCH_PIN2
Pink
25
Power + 12V
Red
26
Power GND
Black
RJ45
GPIO
13
GPI2
Orange / Black
14
GPO2
Yellow / Red
15
GPI1
Orange / Red
16
GPO1
Yellow / Red
17
GPI0
Orange
18
GPO0
Yellow
20
GPIO_GND
Black / Red