User Information

  

Safety Relays from IDEM           SCR-7 

H04 

Ver. A 

E61-329-00 

Maintenace 

The  device  must  be  checked  once  per  month  for  proper 
function  and  for  signs  of  tampering  and  bypassing  of  the 
safety function.

 

Techn. Data 

Corresponds to the standards 

EN 60204-

1; EN ISO 13849

-

1 ; EN 62061

 

Operating voltage 

 

AC/DC 24V      

Rated Supply Frequency 

 

AC: 50-60Hz 

Permissible deviation 

 

+ / - 10% 

Power consumption 

 

DC 24V 

AC 24V 

 

 

approx. 4.5W   approx. 8.5VA 

Control voltage at S11 

 

DC 24V 

Control current S11..S14 

 

approx. 250mA 

Safety contacts 

 

7 NO contacts 

Auxiliary contacts  

 

4 NC contacts 

Auxiliary transistor outputs (O1, O2) 

DC 24V / 30mA, over current protected 

Max. switching voltage 

 

AC 250V 

Safety contact breaking capacity  

AC: 

250V, 2000VA, 8A for ohmic load 

(6 switching cycles/ min)

 

(13-14, 23-24, 33-34,43-44, 53-54, 63-64, 73-74)    

 

250V, 3A for AC-15 

 

 

DC:   40V, 320W, 8A for ohmic load 

(6 switching cycles/ min)

 

 

 

 

24V, 3A for DC-13 

 

 

Max. total current through all 7 contact  up to Ta=40°C: 

 

 

 

35A  

10mm spacing between the devices 

 

 

 

20A 

no spacing between the devices 

Auxiliary contacts braking capacity 

AC: 

250V, 2000VA, 8A for ohmic load  

(81-82, 91-92, 101-102,101-112) 

DC: 

40V, 320W, 8A for ohmic load 

Minimum contact load 

 

24V, 20mA 

Contact fuses 

 

10A gG 

Line cross section 

 

0.14 - 2.5mm

2

 

Max. length of control line 

 

1000m at 0.75 mm

2

  

Contact material 

 

AgSnO

2

 

Contact service life 

 

mech. approx. 1 x 10

7

, electr. 1 x 10

5

 operating cycles 

Test voltage 

 

2.5kV (control voltage / contacts) 

Rated impulse withstand voltage, leakage path/air gap 

4kV 

(DIN VDE 0110-1) 

Rated insulation voltage 

 

250V 

Degree of protection 

 

IP20 

Temperature range 

 

-15°C bis +40°C   

 

 

 

Degree of contamination 

 

(DIN VDE 0110-1) 

Overvoltage category 

 

(DIN VDE 0110-1) 

Weight 

 

approx. 350g 

Mounting 

 

DIN rail according to EN 60715 TH35 

Note: 

Additional data can be requested from the manufacturer for 
applications that deviate from these conditions. 

Safety 
Characteristics 
According to 
EN ISO 13849-1 
 

The device is certified according to EN ISO 13849-1 up to a 
Performance Level of PL e. 

Device cannot be switched on again after an emergency 
stop:  

• 

Check whether the emergency stop circuit was closed 
again. 

• 

Was the start button opened before closing of the emer-
gency stop circuit (with manual start)? 

• 

Is the feedback loop closed? 

If  the  fault  still  exists,  perform  the  steps  listed  under 
“Commissioning Procedure”. 

If  these  steps  do  not  remedy  the  fault  either,  return  the 
device to the manufacturer for examination. 

Opening  the  device  is  impermissible  and  will  void  the 
warranty.  

Device does not switch on: 

• 

Check the wiring by comparing it to the wiring diagrams. 

• 

Check the safety switch used for correct function and 
adjustment. 

• 

Check whether the emergency stop circuit is closed. 

• 

Check whether the start button (with manual start) is 
closed. 

• 

Check the operating voltage at A1 and A2. 

• 

Is the feedback loop closed? 

What to Do in 
Case of a Fault? 

The  device  is  otherwise  maintenance 
free,  provided  that  it  was  installed  pro-
perly.

 

Safety characteristics according to EN ISO 13849-1 for all variants of SCR-7 

Load (DC-

13; 24V)

 

<= 0,1A 

<= 1A 

<= 2A 

T10d [years] 

20 

20 

20 

Category 

PL 

PFHd [1/h] 

2,47E-08 

2,47E-08 

2,47E-08 

nop [cycle / year]  

<= 500.000 

<= 350.000 

<= 100.000 