WindO/I-NV4 User’s Manual
10-209
11 Calendar
10
Da
ta
D
isp
la
ys
■
Day of the Week Settings
Configures the content to be displayed as the day of the week. These options can only be configured when
Clock
or
Clock & Alarm
is selected for
Calendar Type
and
Date & Day of the Week & Time
,
Date & Day of the Week
,
Time & Date & Day of the Week
,
Time & Day of the Week
,
Day of the Week & Time
or
Day of the Week
is
selected for
Clock Type
.
●
Alarm
Tab
These options can only be configured when
Alarm
or
Clock & Alarm
is selected for
Calendar Type
on the
General
tab.
■
Alarm Time
Selects the type of data for the alarm time.
Type:
Selects the string to indicate the day of the week from the following:
(
日
), (
月
), ..., (
土
), Sun., Mon., ..., Sat., Sunday, Monday, ..., Saturday,
星期日
,
星期一
, ...,
星期六
, Customize
When
Customize
is selected, configures the string to indicate the day of the week. The maximum
number is 10 characters.
(Alarm conditions)
Value:
Specifies the alarm time as values and the day of the week.
Year:
Enter the year (0 to 99).
Month:
Enter the month (1 to 12).
Day:
Enter the day (1 to 31).
Day of the Week: Select the day of the week.
Hour:
Enter the hour (0 to 23).
Minute:
Enter the minute (0 to 59).
Second:
Enter the second (0 to 59).
Device Address: Configures the alarm time as values of word devices.
It handles as a value whose data type is BCD4(B). Configures the year, month, day, hour, minute, and
second values in the same range as
Value
. Specifies the day of the week with the following values.
0: Sunday, 1: Monday, 2: Tuesday, 3: Wednesday, 4: Thursday, 5: Friday, 6: Saturday
Click
to display the Tag Editor. For the device address configuration procedure, refer to Chapter
2 “5.1 Device Address Settings” on page 2-70.
If the data of the alarm time is invalid, 1 is written to System Area 2 Processing error bit (address
2, bit 5), and an error message is displayed. For details, refer to Chapter 4 “Processing error” on
page 4-32 and Chapter 36 “Processing error” on page 36-3.
An error occurs in the following states:
•
Year
,
Month
,
Day
,
Hour
,
Minute
or
Second
are set to values outside the range of
Value
.
• A value outside the range of BCD4(B) is entered.
Содержание WindO/I-NV4
Страница 1: ...B 1701 16 User s Manual...
Страница 50: ...1 WindO I NV4 Specifications 2 18 WindO I NV4 User s Manual Baltic ANSI 1257 Cyrillic ANSI 1251...
Страница 108: ...5 WindO I NV4 Common Operations and Settings 2 76 WindO I NV4 User s Manual...
Страница 256: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual...
Страница 372: ...6 Screen Restrictions 5 32 WindO I NV4 User s Manual...
Страница 390: ...5 Part Library Function 6 18 WindO I NV4 User s Manual...
Страница 420: ...3 Text 7 30 WindO I NV4 User s Manual...
Страница 522: ...5 Key Button 8 102 WindO I NV4 User s Manual Password Input These keys switch the user on the Password Input Screen...
Страница 628: ...2 Multi State Lamp 9 34 WindO I NV4 User s Manual...
Страница 924: ...4 Meter 11 76 WindO I NV4 User s Manual...
Страница 990: ...7 Timer 12 66 WindO I NV4 User s Manual...
Страница 1030: ...4 Using Data and Detected Alarms 13 40 WindO I NV4 User s Manual...
Страница 1098: ...4 Using the Data 15 22 WindO I NV4 User s Manual...
Страница 1248: ...5 Restrictions 22 18 WindO I NV4 User s Manual...
Страница 1370: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual...
Страница 1388: ...4 Restrictions 26 18 WindO I NV4 User s Manual...
Страница 1546: ...5 Module Configuration Dialog Box 30 36 WindO I NV4 User s Manual...
Страница 1614: ...3 Settings 34 14 WindO I NV4 User s Manual...
Страница 1694: ...5 HG1P 35 80 WindO I NV4 User s Manual 5 6 Dimensions Unit mm Cable Dimensions 191 169 56 70 6 51 55 7...
Страница 1726: ...5 Text Alignment A 10 WindO I NV4 User s Manual...