WindO/I-NV4 User’s Manual
15-21
4 Using the Data
15
Op
era
tio
n L
og
F
un
ctio
n
4.1 Saving the Data as a CSV File
●
Saving the Data as a CSV File
The Operation Log data can be saved to the external memory device
as a CSV file or uploaded to a computer.
The procedure to save the data is as follows.
• To save the data to an external memory device, click
Operation Log
on the WindO/I-NV4
Configuration
tab to
open the Operation Log Settings dialog box. Select an output method check box on the
External Memory Device
tab and configure the items. The Operation Log data is saved to the External Memory Device folder on the external
memory device according to the
External Memory Device
tab settings. For details, refer to “External Memory
•
To upload the data to a computer, click on
▼
to the right of
(Upload) on the toolbar in Data File Manager, and
then click the
Upload All Log Data
or
Upload Data Operation Log Data
to open the Browser For Folder dialog
box. Specify the location to save the file and click
OK
to save the file to the specified folder. For details, refer to the
Data File Manager User's Manual.
●
Data Structure and Output Example
The data structure of the output file is as follows. The data structure for files output with batch output and real time
output is the same.
Bold items are replaced by the Operation Log settings, the recorded data, the running project name, and WindO/I-
NV4 version number.
*1 USB flash drive inserted in USB1 for HG2J-7U, SD memory card for HG5G/4G/3G/2G-V, HG4G/3G and HG2G-5F,
USB flash drive for HG2G-5T and HG1G/1P
4
Using the Data
HG3G
HG2G-5F
HG5G-V HG4G-V
HG3G-V
HG2G-V
HG2G-5T
HG4G
HG1G HG1P
HG2J-7U
Headers
"Project Name","
Project name
","
Version number
"
"File Type","
Log type
"
Blank row
Label row
"
Sampling Time
","
User Name
","
Screen No.
","
Event Name
","
Part Name
","
Device
Address
","
Changed to
"
Data row
"
MM/DD/YYYY hh:mm:ss
","
User Name
","
Screen Type & No.
","
Event
","
Part
Name
","
Device Address
","
Changed to
"
··
·
Output example
Data size of each row
"Project Name","Dimmer Console","V4.50"
- 41 bytes
"File Type","Operation Log Data"
- 34 bytes
- 2 bytes
"Sampling Time","User","Screen No.","Operation","Part Name","Details",
"Changed to"
- 85 bytes
" 12/01/2011 12:00:10","-","Base 1","Power ON","-","-","-"
- 60 bytes
" 12/01/2011 12:01:23","User1","Base 1","Switch to Base Screen","-","-",
"Base2"
- 81 bytes
··
·
• The data size for each row is counted as 2 bytes for full-width characters, 1 byte for half-width characters,
and 2 bytes for newlines. The total for each row is the total amount of space for the file.
• A space is inserted before the date in the data row.
• The display type for the date and time varies based on the language configured in
Project Settings
, on
the
Project Details
tab, in
Language
.
Japanese: YYYY/MM/DD hh:mm:ss
Western,
Simplified Chinese, Traditional Chinese, Hangul, Central European, Baltic, Cyrillic
:
MM/DD/YYYY hh:mm:ss
Содержание WindO/I-NV4
Страница 1: ...B 1701 16 User s Manual...
Страница 50: ...1 WindO I NV4 Specifications 2 18 WindO I NV4 User s Manual Baltic ANSI 1257 Cyrillic ANSI 1251...
Страница 108: ...5 WindO I NV4 Common Operations and Settings 2 76 WindO I NV4 User s Manual...
Страница 256: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual...
Страница 372: ...6 Screen Restrictions 5 32 WindO I NV4 User s Manual...
Страница 390: ...5 Part Library Function 6 18 WindO I NV4 User s Manual...
Страница 420: ...3 Text 7 30 WindO I NV4 User s Manual...
Страница 522: ...5 Key Button 8 102 WindO I NV4 User s Manual Password Input These keys switch the user on the Password Input Screen...
Страница 628: ...2 Multi State Lamp 9 34 WindO I NV4 User s Manual...
Страница 924: ...4 Meter 11 76 WindO I NV4 User s Manual...
Страница 990: ...7 Timer 12 66 WindO I NV4 User s Manual...
Страница 1030: ...4 Using Data and Detected Alarms 13 40 WindO I NV4 User s Manual...
Страница 1098: ...4 Using the Data 15 22 WindO I NV4 User s Manual...
Страница 1248: ...5 Restrictions 22 18 WindO I NV4 User s Manual...
Страница 1370: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual...
Страница 1388: ...4 Restrictions 26 18 WindO I NV4 User s Manual...
Страница 1546: ...5 Module Configuration Dialog Box 30 36 WindO I NV4 User s Manual...
Страница 1614: ...3 Settings 34 14 WindO I NV4 User s Manual...
Страница 1694: ...5 HG1P 35 80 WindO I NV4 User s Manual 5 6 Dimensions Unit mm Cable Dimensions 191 169 56 70 6 51 55 7...
Страница 1726: ...5 Text Alignment A 10 WindO I NV4 User s Manual...