Function Setting
3-2-2 Floating Blanking Function
FLO1 <Effective setting of beam channel>
0: Ineffective
1: 1 beam channel setting
2: 2 beam channels setting
3: 3 beam channels setting
FLO2 <Ineffective setting of both end beam channel>
SET (Effective) : Both ends of the beam channels are not subject to the float blanking function
CLR (Ineffective) : All beam channels are subject to the floating blanking function
FLO3 <Non serial beam channel setting>
SET (Effective) : Non-serial beam channel mode
CLR (Ineffective) : Serial beam channel mode
Note: When “all sensors” is selected in the sensor selection, the setting of the floating blanking function on each
SE4D
series
should be identical.
(Sub sensor 2)
Sensor selection
(All sensors)
(Main sensor)
(Sub sensor 1)
Set No. of beam channel
(Ineffective)
Input
password
Send
(Error)
To 2
OK
NG
To 2
Send
(Error)
OK
NG
(Ineffctive)
(Effctive)
(Ineffctive)
(Note)
(Effctive)
Ineffective setting
for both ends
beam channels
Setting
for
non-serial beam
channel
One beam
channel effecive
Two beam
channel effecive
Three beam
channel effecive
3. To Auxiliary
output switching
function
2. Floating blank-
ing function
key operation
: FUNCTION
: ENTER
: CANCEL
: -
: +