IDEC PS3V Скачать руководство пользователя страница 10

PS3V Switching Power Supplies

For details on mounting, wiring, and circuit examples, see the instruction manual from the below URL.

URL: https://product.idec.com/?product=PS3V

Instructions

Notes for installation

1. When mounting the PS3V, see page

 

7

.

2. See page 

7

 and 

8

 for mounting hole layout. 

3. Use M3 or M4 screw as mounting screws. The tightening torque of 

the mounting screw is 0.49N·m.

Power supply chassis

Mounting panel

Mounting screw

6mm max.

(PS3V-015

:

3.5mm max.)

4. Do not close the openings of the switching power supply. Ensure 

proper heat dissipation by convection.

5. Maintain a minimum of 20 mm clearance around the switching 

power supply.

6. When derating of the output does not work, provide forced air-

cooling.

7. Make sure to wire the ground terminal correctly.
8. Use copper wire only. In addition,  refer to the below table to select 

wire types  and number of wires.

Terminal

Wire size (Allowable current)

Wire type

Input 

AWG18 to 14

Copper, solid/stranded

Output

AWG18 to 14

(AWG18-7A, AWG16-10A,  

AWG14-15A

• Cross section -  AWG18: 0.82mm

2

,  AWG16: 1.31mm

2

, AWG14: 2.08mm

2

• See page 

11

 for Push-in type

9. Recommended tightening torque of terminal screws: 0.8 N·m  

(PS3V-015

: 0.5N·m)

Adjustment of output voltage

The output voltage can be adjusted within ±10% of the rated output 
voltage by using the V.ADJ control. Turning the V.ADJ clockwise 
increases the output voltage. Turning counterclockwise decreases the 
output voltage. Note that overvoltage protection may function when 
output voltage is increased.

Overcurrent protection

The output voltage drops automatically when an overcurrent flows, 
resulting in intermittent operation. Normal voltage is automatically 
restored when the load returns to normal condition. However, 
overcurrent for a prolonged period of time or short-circuit causes the 
internal elements to deteriorate or break down.

Overvoltage protection

• PS3V-015

Voltage limit and auto-recovery method. The switching power supplies 
operate normally when voltage returns to normal.

• PS3X-030

, -050

, -100

, -150

:

The output is turned off or intermittent operation when an overvoltage 
is applied. When the output voltage has dropped due to an overvoltage, 
turn the input off, and after one minute, turn the input on again.

Insulation/Dielectric test

When performing an insulation/dielectric test, short the input (between 
AC) and output (b and –). Do not apply or interrupt the voltage 
suddenly, otherwise surge voltage may be generated and the power 
supply may be damaged.

Noise

Small acoustic noise inside the PS3V may be heard depending on the 
input voltage and load, but the performance of the PS3V is not affected.

Series operation

The following series operation is allowed. In (b) series operation, 
connect Schottky barrier diodes. Choose (a) series operation when 
using the PS3V as positive and negative output power supply. Insert 
a Shottky barrier diode for loads such as operational amplifier where 
outputs of two power supplies may be connected in series (Load 3). 
Select a Schottky diode in consideration of the rated current. 

L

N

L

N

+V

–V

L

N

+V

–V

Load

(a)

L

N

L

N

+V

–V

L

N

+V

–V

Load 3

(b)

Load 1

Load 2

Parallel operation

Parallel operation is not possible to increase the output capacity, 
because the internal elements and load may be damaged.
Backup operation is a connection method of two switching power 
supplies in parallel for emergency. Normally one switching power 
supply has a sufficient output. If one switching power supply fails, 
another one operates to continue the output. Make sure that the sum 
of power consumption by load and diode is not greater than the rated 
wattage (rated voltage × rated current) of one switching power supply. 
The current of the diode that is used must be more than double the 
output current of PS3V. Take heat dissipation into consideration.

+

IN

AC

OUT

+

IN

OUT

Load

D

D

Rust and scratches on metal parts

Hot-dip galvanized steel and bonderized steel are used for the PS3V. 
Rust on the edge and scratches on the surfaces may be developed 
depending on the storage condition, but the performance of the PS3V 
is not affected.

10

Содержание PS3V

Страница 1: ...Switching Power Supplies PS3V Compact Reliable Power Supplies Flexible installation allows mounting in four directions ...

Страница 2: ...ilities such as buildings Operates in temperatures ranging from 25 to 70 C Ideal for use in various storage facilities such as freezers and refridgerators Warehouse storage Compact Operating Temperature Push in connection As a manufacturer of factory automation products we provide total solutions and related PLCs HMI products One step wiring Safe and effiecient push in connection Push in models av...

Страница 3: ...rage Car facilities Logistics and transport facilities Agricultural facilities Energy related facilities others QR codes are printed on the product enabling easy access to the latest instruction manuals Safety Standards Mounting examples When PS3V 030AF is mounted standard mount with PS9Z 3E3C mounting bracket Direct mount DIN rail mount When PS3V 050AF is mounted standard mount with PS9Z 3E3B mou...

Страница 4: ...PS3X L shaped mounting brackets PS9Z 3N3B cannot be used L shaped mounting bracket is not available for PS3V 150AF PS9Z 3N3B L shaped mounting brackets cannot be used for PS3V 150AF Part no configuration DIN rail End clip Tools Specify the Ordering no when ordering Name Part No Ordering No Package quantity Remarks 35mm DIN rail BAA1000 BAA1000PN10 10 Material Aluminum Weight 200g Length 1 000mm En...

Страница 5: ...x 12V 2 5 p p max 24V 1 5 p p max 12V 2 5 p p max 24V 1 5 p p max 24V 1 5 p p max 0 to 50 C 5V 2 5 p p max 12V 1 5 p p max 24V 1 p p max 5V 2 5 p p max 12V 1 5 p p max 24V 1 p p max 12V 1 5 p p max 24V 1 p p max 24V 1 p p max Supplementary functions Overcurrent protection 105 min auto reset 2 Overvoltage protection 120 min intermittent auto reset Output off at 120 min reset when re input Operation...

Страница 6: ... 85 100 264 0 10 20 30 40 50 60 70 80 90 100 85 90 264 0 20 40 60 80 100 Input Voltage VAC 85 100 264 0 20 40 60 80 100 Output Current Input Voltage VAC Output Current Input Voltage VAC Output Current PS3V 015AF 030AF PS3V 050AF Areas indicated with may take time for the output voltage to stabilize Overcurrent detection Detection L N INPUT Control Line filter Switching Fuse Rectifier Rectifier V A...

Страница 7: ...F Note Note the terminal arrangement when wiring AC L AC N V V V ADJ LED AC L AC N V V V ADJ LED AC L AC N V V V ADJ LED AC L AC N V V V ADJ LED AC L AC N V V V ADJ LED V V AC L AC N V V V ADJ LED V AC L AC N V V V V ADJ LED AC L AC N V V V V ADJ LED AC L AC N V V V V V V V ADJ LED PS3V 050AF PS3V 030AF PS3V 100AF PS3V 100AF Horizontal terminal type Push in terminal type Note 15W is not available ...

Страница 8: ... Depth 6mm max 2 M3 Depth 6mm max 8 2 9 5 Terminal Centers 17 10 5 80 34 5 2 M3 95 5 68 5 101 2 M3 36 5 15 70 7 5 Input terminal centers Depth 6mm max 5 0 Output terminal centers Depth 6mm max 80 45 5 23 5 55 99 17 5 7 74 36 2 M3 2 M3 104 5 7 5 Input terminal centers 5 0 Output terminal centers Depth 6mm max Depth 6mm max 108 49 93 12 5 76 10 18 14 77 19 39 3 M3 113 5 2 M3 7 5 Input terminal cente...

Страница 9: ...lectric Facilities for General Use When using the product follow the following precautions Precautions on switching power supplies This product is for industrial or general electronic equipment such as communication measurement and industrial electronic equipment Do not use for devices that may cause malfunction or may harm the body or threaten human life Make sure that the input voltage and outpu...

Страница 10: ... supplies operate normally when voltage returns to normal PS3X 030 050 100 150 The output is turned off or intermittent operation when an overvoltage is applied When the output voltage has dropped due to an overvoltage turn the input off and after one minute turn the input on again Insulation Dielectric test When performing an insulation dielectric test short the input between AC and output betwee...

Страница 11: ...al disasters Warranty Accessories and wiring for Push in terminals Wire size and recommended ferrules Push in terminal type only Ferrules with insulated covers Applicable Wire Stranded Wire Wire Strip Length mm Part No Ordering No AWG mm2 For 1 wire 18 0 75 12 S3TL H075 16WW 17 1 0 12 S3TL H10 16WY 16 1 5 12 S3TL H15 16WR For 2 wires 18 0 75 21 S3TL J075 19WWS Recommended tools Optional See page 4...

Страница 12: ...spections We ask that you implement inspections for IDEC products you purchase without delay as well as thoroughly keep in mind management maintenance regarding handling of the product before and during the inspection 4 Warranty 1 Warranty period The warranty period for IDEC products shall be five 5 years after purchase or delivery to the specified location However this shall not apply in cases wh...

Отзывы: