
WindO/I-NV4 User’s Manual
10-7
1 Numerical Input
10
Data Displa
ys
■
Input Method
These options specify the destination for entered values.
■
Always Entry Mode
Select this check box to enter values by pressing the keypad and key buttons without touching the Numerical Input
displayed on the screen.
To display 0 on the Numerical Input until a value is entered, select the
Start from 0 in Always Entry Mode of
Numerical Input
check box on the
System
tab in the
Project Settings
dialog box. To display the value of device
address, clear the
Start from 0 in Always Entry Mode of Numerical Input
check box.
This option can only be configured if
Current Screen
is selected for
Type
.
Example: When the
Always Entry Mode
check box is selected and the
Start from 0 in Always Entry Mode of
Numerical Input
check box is selected on the
System
tab in the
Project Settings
dialog box
Example: When the
Always Entry Mode
check box is cleared
*1 Advanced mode only
Destination Device Address:
Specifies the word device to write the entered value to.
Click
to display the Tag Editor. For the device address configuration procedure,
refer to Chapter 2 “5.1 Device Address Settings” on page 2-68.
Use Reference Device Address
: Select this check box and specify a device address to change the destination word
device by the value of this device address.
Click
to display the Tag Editor. For the device address configuration procedure,
refer to Chapter 2 “5.1 Device Address Settings” on page 2-68.
For details on indirect writing, refer to Chapter 2 “Indirect Read and Indirect Write
Settings” on page 2-5.
Enter a value
Display value being entered
(Entry mode)
Display 0
(Entry mode)
Press
ENT
Write value to device address
(Entry mode)
0
Action
Operations and display
999
999
Value of
Destination Device Address
999
1234
1234
Not displayed on Numerical Input.
Only one Numerical Input or one Character Input set to
Always Entry Mode
can be configured for one
screen.
Press Numerical Input
Enter a value
Enter 999
Press
ENT
Display value of
device address
(Entry mode)
Write value to
device address
(Entry mode)
Display value of
device address
(Display mode)
Display focus
(Entry mode)
Display value of
device address
(Display mode)
1234
Operations and display
1234
999
Value of
Destination Device Address
Action
1234
999
999
1234
1234
1234
999
Содержание MICRO/I HG4G-CJT22 F-B Series
Страница 1: ...B 1701 11 User s Manual ...
Страница 26: ...Preface 25 WindO I NV4 User s Manual ...
Страница 50: ...1 WindO I NV4 Specifications 2 18 WindO I NV4 User s Manual Baltic Font ANSI 1257 Cyrillic Font ANSI 1251 ...
Страница 106: ...5 WindO I NV4 Common Operations and Settings 2 74 WindO I NV4 User s Manual ...
Страница 254: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual ...
Страница 362: ...5 Screen Restrictions 5 28 WindO I NV4 User s Manual ...
Страница 402: ...3 Text 7 30 WindO I NV4 User s Manual ...
Страница 574: ...9 Potentiometer 8 172 WindO I NV4 User s Manual ...
Страница 1052: ...4 Using the Data 15 22 WindO I NV4 User s Manual ...
Страница 1170: ...6 Important Notes 20 60 WindO I NV4 User s Manual ...
Страница 1200: ...5 Restrictions 22 18 WindO I NV4 User s Manual ...
Страница 1260: ...5 Editing User Accounts on the MICRO I 23 60 WindO I NV4 User s Manual ...
Страница 1286: ...4 Clear 24 26 WindO I NV4 User s Manual 4 Click Yes 5 Click Close This concludes clearing data ...
Страница 1288: ...4 Clear 24 28 WindO I NV4 User s Manual 6 Click Yes 7 Click Close This concludes clearing data on the external memory device ...
Страница 1322: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual ...
Страница 1414: ...4 E mail Function 28 66 WindO I NV4 User s Manual ...
Страница 1554: ...3 Settings 34 14 WindO I NV4 User s Manual ...
Страница 1642: ...2 Handling Problems 36 6 WindO I NV4 User s Manual ...
Страница 1652: ...5 Text Alignment A 10 WindO I NV4 User s Manual ...
Страница 1664: ...Index 12 WindO I NV4 User s Manual ...