2 Word Devices
33-6
WindO/I-NV4 User’s Manual
2.1 HMI Device Addresses
■
HMI Data Register (LDR)
8192 points are available.
■
HMI Keep Register (LKR)
The value in these registers is retained during power OFF. The maximum number of HMI Keep Register depends upon
the number set in WindO/I-NV4. For details, refer to Chapter 16 “Minimum and Maximum Amount of Data Storage
and Number of Addresses” on page 16-2.
■
HMI Timer Current Value (LTD)
This register stores the current value of Timer from the parts. 32 points are available.
■
Digital Input (Word) (WLEX), Digital Output Word (WLEY)
These registers handle the relays for digital inputs (words) and digital outputs (words) of expansion modules
connected to the HG4G/3G and HG2G-5F in word units. For details, refer to Chapter 30 “2.1 Using Digital I/O
Modules” on page 30-12.
■
HMI Temporary Register (LBR)
This register can be used to store value as temporary. This register value will be cleared to 0 when a text
group or user account is changed, when a screen is reset or the screen is changed. 128 points are available.
■
HMI Link Register (LLR)
An area that stores the data of the registered device addresses for the external device during Sub Host
Communication.
64 points are available.
This register can also be used as an internal register like LDR when Sub Host Communication is not used.
■
HMI Expansion Input (Word) (WLI), HMI Expansion Output (Word) (WLQ)
These registers handle the expansion input or the expansion output used with HG1P in word unit. WLQ is
a reserved area.
*1 HG4G/3G, HG2G-5F only
*2 HG1P only
*3 HG5G/4G/3G/2G-V only
2
Word Devices
Internal Device Name
Symbol
R/W
Address Range
Base
HMI Data Register
LDR
R/W
0 to 8191
10
HMI Keep Register
LKR
R/W
Variable
10
HMI Timer Current Value
LTD
R
0 to 31
10
Digital Input (Word)
WLEX
R
0, 20, 40, 60
10
Digital Output (Word)
WLEY
R/W
0, 20, 40, 60
10
HMI Temporary Register
LBR
R/W
0 to 127
10
HMI Link Register
LLR
R/W
0 to 63
10
HMI Expansion Input (Word)
WLI
R
0
16
HMI Expansion Output (Word)
WLQ
R/W
0
16
HMI Special Data Register
LSD
R/W
0 to 383
0 to 255
10
HG3G
HG2G-5F
HG5G-V HG4G-V
HG3G-V
HG2G-V
HG2G-5T
HG4G
HG1G HG1P
R/W is an abbreviation of Read/Write. R/W indicate that both reading and writing are possible, while R
indicates that only reading is possible.
Содержание MICRO/I HG4G-CJT22 F-B Series
Страница 1: ...B 1701 11 User s Manual ...
Страница 26: ...Preface 25 WindO I NV4 User s Manual ...
Страница 50: ...1 WindO I NV4 Specifications 2 18 WindO I NV4 User s Manual Baltic Font ANSI 1257 Cyrillic Font ANSI 1251 ...
Страница 106: ...5 WindO I NV4 Common Operations and Settings 2 74 WindO I NV4 User s Manual ...
Страница 254: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual ...
Страница 362: ...5 Screen Restrictions 5 28 WindO I NV4 User s Manual ...
Страница 402: ...3 Text 7 30 WindO I NV4 User s Manual ...
Страница 574: ...9 Potentiometer 8 172 WindO I NV4 User s Manual ...
Страница 1052: ...4 Using the Data 15 22 WindO I NV4 User s Manual ...
Страница 1170: ...6 Important Notes 20 60 WindO I NV4 User s Manual ...
Страница 1200: ...5 Restrictions 22 18 WindO I NV4 User s Manual ...
Страница 1260: ...5 Editing User Accounts on the MICRO I 23 60 WindO I NV4 User s Manual ...
Страница 1286: ...4 Clear 24 26 WindO I NV4 User s Manual 4 Click Yes 5 Click Close This concludes clearing data ...
Страница 1288: ...4 Clear 24 28 WindO I NV4 User s Manual 6 Click Yes 7 Click Close This concludes clearing data on the external memory device ...
Страница 1322: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual ...
Страница 1414: ...4 E mail Function 28 66 WindO I NV4 User s Manual ...
Страница 1554: ...3 Settings 34 14 WindO I NV4 User s Manual ...
Страница 1642: ...2 Handling Problems 36 6 WindO I NV4 User s Manual ...
Страница 1652: ...5 Text Alignment A 10 WindO I NV4 User s Manual ...
Страница 1664: ...Index 12 WindO I NV4 User s Manual ...