IDEC LUMIFA LF1D Скачать руководство пользователя страница 12

www.idec.com

USA 

IDEC Corporation 

Tel: +1-408-747-0550  [email protected]

Germany 

APEM GmbH 

Tel: +49-40-25 30 54-0 [email protected]

Singapore 

IDEC Izumi Asia Pte. Ltd. 

Tel: +65-6746-1155 

[email protected]

Thailand 

I

DEC Asia (Thailand) Co., Ltd 

Tel: +66-2-392-9765  [email protected]

Australia 

IDEC Australia Pty. Ltd. 

Tel: +61-3-8523-5900 [email protected]

India 

IDEC Controls India Private Limited  Tel: +91-80679-35328  [email protected]

Taiwan 

IDEC Taiwan Corporation 

Tel: +886-2-2577-6938  [email protected]

Hong Kong 

IDEC Izumi (H.K.) Co., Ltd.  Tel: +852-2803-8989 

[email protected]

China 

I

DEC (Shanghai) Corporation Tel: 

+86-21-6135-1515 [email protected]

 

Beijing Branch 

Tel: +86-10-6581-6131  [email protected]

 

Guangzhou Branch  Tel: +86-20-8362-2394  [email protected]

Japan 

IDEC Corporation 

Tel: +81-6-6398-2527  [email protected]

Head Office

6-64, Nishi-Miyahara-2-Chome, Yodogawa-ku, Osaka 532-0004, Japan

Specifications and other descriptions in this brochure are subject to change without notice.

Information in this brochure is current as of May, 2021.

2021 IDEC Corporation, All Rights Reserved. 
EP1752-1

Related products

Durable and compact slim power relays with high contact 
allowable current.

High performance DIN rail power supplies with low profile, space 
saving 6-direction mounting, and spring-up terminals for wiring 
efficiency and safety. Mounting brackets are also available for 
direct mounting. Compliant with SEMI-F47 standards. (Certified 
for 208V AC input voltage.)

Reduce the cost of relay replacement

Prevent momentary stops that cause machine failures

RJ

PS5R-V

Slim power relays

Switching power supplies

Safey relay module to monitor and diagnose safety systems. 
Improves productivity by predictive maintenance of safety 
systems.

Diagnose and monitor safety systems 

HR6S

Safety relay modules

The compact RFID reader mounts on ø22 panel cut-out. 
Water- and oil-proof with verification functions. Suitable for 
controlling and tracking access to production sites.

Smart RFID reader to manage user authority/log control

KW2D

Smart RFID reader

HS5L:   4-contact switches suitable for small doors. 2-contact switches 

suitable for food machinery and injection molding machines.

HS1T:  5000N locking strength is suitable for large machines and 

equipment, ensuring operator safety.

HS5L

HS1T

Interlock switches with solenoid

Conforms to ISO 13856-2 (pressure-sensitive protective devices). 
Ensures safety without reducing the opening/closing speed of 
automatic doors. The rubber part is made of oil-resistant NBR 
material, suitable for environments where oil mist is dispersed.

E30BK1

Safety edge switches

Available August, 2021

Compact safety pressure sensitive switch 

conforming to ISO13856-2

A wide variety of safety switches covers small 

to large-size machine tools

Machine tools industry solutions

Find out how IDEC has solved customers' problems in the 
machine tools industry.

Содержание LUMIFA LF1D

Страница 1: ...LED Lighting LF3D LF1D Excellent optical performance and robust construction suitable for use in machine tools TM ...

Страница 2: ...to see scratches and unevenness on the workpiece LF3D lighting makes it possible to check whether chatter marks have been generated or not easily at a glance Hard to see chatter marks Glares from LED lighting inside the machine tool could be mistaken as chatter marks while visually checking the machine operation This often caused chatter marks to be left untreated delaying maintenance and worsenin...

Страница 3: ...ned by development of LED lighting sensors and by optimum LED alignment the brightness contrast difference is improved by 85 The LF3D LED allows the light to be evenly distrib uted to provide natural lighting and enables visual inspection Patent pending LF3D Conventional Product LF3D LED Brightness contrast difference Bright Dark Bright Dark Brightness distribution of illumina tion surface Differe...

Страница 4: ...losed 100 illumination door closed Application example Functions with opening closing of doors switching with control panel At least 500 lx shall be provided when arranging lighting for machines EN1837 1999 A1 2009 4 2 LED lighting 500lx min Standard distribution Diffused distribution Switch etc 0V 24V DC White pin No 2 Blue pin No 3 Brown pin No 1 Modes can be changed by just the wiring Complicat...

Страница 5: ...D H 840 lx LF1D J Dimensions W H D 55 8 17 5 310 mm 80 27 307 mm 84 24 8 365 mm LF1D H 84 24 8 510 mm LF1D J Compact slim and light compared to conventional products Weight 30 DOWN Weight 25 DOWN Luminous efficiency 37 UP Mass 50 DOWN Wide variety of connector types available Easy replacement with conventional products Panel cut out for older LED lighting will fit the new LF3D LED Accessories for ...

Страница 6: ... No corrosive gas Light source life 1 50 000 hours The illumination duration in which the brightness maintains a minimum of 70 Ta 25ºC 45 RH max Degree of protection 2 Surface mount IP65 IP67 IP67G IP69K Recessed mount IP65 IP67 IP67G Glare save mode GS Mode 3 White wire pin no 1 open 100 light on White wire pin no 1 and brown wire pin no 2 short circuit dim light Material Main parts Main body Alu...

Страница 7: ...ge temperature 35 to 70 C no freezing Operating atmosphere No corrosive gas Light source life 1 50 000 hours The illumination duration in which the brightness maintains a minimum of 70 Ta 25ºC 45 RH max Degree of protection 2 IP67 IP67F IP69K Material Main parts Main body Aluminum Front cover surface mount Stainless steel Illumination part surface Reinforced glass Gasket NBR Weight approx LF1D H2F...

Страница 8: ...cable type 33 34 5 M12 connector type Connector Wiring LF3D surface mount M8 connector Pin No Wiring color Function Connection Brown DC Power Supply 24V White GS Mode Open or DC Blue DC Power Supply 0V GND N C Use a connector on a power supply side that satisfies the required degree of protection Recommended connector Harting M8 connector Phoenix Contact M12 connector Illumination surface Front co...

Страница 9: ...ounting hole layout and the size of mounting screws on the back of the LED unit see the specification sheet and dimensions supplied with the product Connector Wiring LF1D H J2F 2 B M12 connector 1470 46 8 ø14 8 24V DC 0V DC NC NC Plug 4 pin assignment M12 connector SAC 4P MS SCO 150 1 5 Use a connector on the power sup ply side that satisfies the degree of protection Recommended connector Phoenix ...

Страница 10: ...ions Locations subject to high water pressure environments exceeding protec tion degree IPX5 IPX7X or IPX9K in accordance with IEC 60529 Locations subject to dust environments exceeding protection degree IP6X in accordance with IEC 60529 Environment subject to corrosive gases volatile gases flammable gases or chemicals that could affect the safety and reliability of the product Locations subject t...

Страница 11: ...duct may be handled or used deviating from the specifications or conditions environment listed in the Catalogs such as equipment used outdoors or applications in environments subject to chemical pollution or electromagnetic interference If you would like to use IDEC products in the above applications be sure to consult with an IDEC sales representative 3 Inspections We ask that you implement inspe...

Страница 12: ...ounting brackets are also available for direct mounting Compliant with SEMI F47 standards Certified for 208V AC input voltage Reduce the cost of relay replacement Prevent momentary stops that cause machine failures RJ PS5R V Slim power relays Switching power supplies Safey relay module to monitor and diagnose safety systems Improves productivity by predictive maintenance of safety systems Diagnose...

Отзывы: