background image

B-1902-1(0)

INSTRUCTION SHEET - HS5D Series 

Safety Switch

( 4 / 5 )

2016.08

Applicable Cable Glands

• Use a cable gland with a degree of 

protection IP67.

• Applicable cable gland dimensions

• When using plastic cable gland, metal cable gland and multi-core cable

Plastic cable gland

SCS-10

(made by Seiwa Electric)

ST13.5

(made by K-MECS)

ST-M20X1.5

(made by K-MECS)

Gland port size

G1/2

PG13.5

M20

Metal cable gland

ALS-16

□□

(made by Nihon Flex)

ABS-

□□

PG13.5

(made by Nihon Flex)

ALS-

□□

EC20

(made by Nihon Flex)

• When using flexible conduit and metal cable gland
  Applicable Flexible Conduit Example: Type VF-03 (made by Nihon Flex)

Plastic cable gland

G1/2

PG13.5

M20

Metal cable gland

RLC-103

(made by Nihon Flex)

RBC-103PG13.5

(made by Nihon Flex)

RLC-103EC20

(made by Nihon Flex)

Gland port size

• When using a 1/2-14NPT cable gland, use HS5D safety switch with M20 gland port 

size (Type: HS5D-

□□□

BM) together with adaptor (Type: MA-M/NPT 20X1.5 

5402-0110, 

 

made by K-MECS) and gasket (Type: GP M20, made by K-MECS) 

which are sold separately. Install the gasket between the safety switch and the adap-

tor. Apply a sealing tape between the cable gland and the adaptor so that the enclo-

sure will conform to IP67.

Confirm the outside diameter of the multi-core cable because the cable gland type 

depends on the outside diameter of the multi-core cable.

CAUTION

30mm

maximu

m

9mm

maximu

m

G1/2, PG13.5, M20

7

Example of wiring Diagram realizing Safety Category

L1(+)

DC24V

F1

K4

K3

HS5D-12

Safety Switch

N(-)

L1(+)

N(-)

DC0V

S1

S1

12

11

HR1S-AF Safety relay module

13

14

ESC

K4

K3

S2

S33

S34

13

23

A1

S11

S22

14

24

A2

S12 S21

34
33

DC24V

F1

K4

K3

DC0V

13

14

ESC

K4

K3

S2

S3

1

2

HS5D-12

Safety Switch

HR1S-AF Safety relay module

S33

S34

13

23

A1

S11

S22

14

24

A2

S12 S21

22

21

12

11

34
33

22

21

 S1: HS5D-12 Safety Switch

  S2:  Starting Switch (HW Series Momentary)

  S3:  Safety limit Switch

 ESC:  Outside start condition

  K3, 4:  Safety Contactor

 F1: Outside fuse of safety relay module at power supply line

Note:  Use the monitoring device(Safety relay module) provided the capavility to 

detect a cross  short circuit. The insulation of the cable has to withstand 

environmental influences. If a control device other than the one shown in the 

draft is used, the used control device has to be equipped with a cross short 

circuit monitor.  

Example of a circuit diagram for Safety Category 4

(attainable PL = e)

Example of a circuit diagram for Safety Category 3 

(attainable PL = d)

(Condition 1: To apply  he fault exclusion of mechanical structural parts including  he actuator 

→  Make  sure  to  use  the  product  within  the  product  specification  range  described  in  this 

manual and the version of the manual provided with the product.)

(Condition 2: Documentation of  he reason for the machine/equipment manufacturer to have 

applied the fault exclusion based on ISO13849-1, ISO13849-2 or IEC62061.)

One of the example of 

the circuit ; Safety 

relay module, HR1S-AF 

series manufactured 

by IDEC CORPORATION

One of the example of 

the circuit ; Safety 

relay module, HR1S-AF 

series manufactured 

by IDEC CORPORATION

Output Circuit

Output Circuit

Used as open/close

monitor of guard

Used as open/close

monitor of guard

Guard Open

Guard Open

HS9Z-A51 Actuator

HS9Z-A51 Actuator

Содержание HS5D-11

Страница 1: ...portance to Warning and Caution Warning notices are used to emphasize that improper operation may cause severe personal injury or death Caution notices are used where inattention might cause personal injury or damage to equipment INSTRUCTION SHEET Original Instructions Safety Switch HS5D Series S A F E T Y P R E C A U T I O N S CAUTION WARNING In order to verify if the product you are interested i...

Страница 2: ... safety circuit Turn off he power when using this function CAUTION HS9Z A51A HS9Z A52A When there is a displacement of safety switch and actuateor the actuator may hit the entry slot of safety switch hardly thus damaging the entry slot and acutuator The rubber cushions on the HS9Z actuator prevent the actuator from damaging the entry slit by absorbing the shock with movement flexibility Do not how...

Страница 3: ... manner In these situations other measures see 2 should be put in place to reduce the risks of function failure 2 At least one of the following measures should be applied to prevent function failure 1 Mounting the interlock device in a place out of reach from workers 2 Using shielding protection to prevent physical obstruc ion of the device 3 Mounting the interlock device in a hidden position 4 In...

Страница 4: ... Safety relay module 13 14 ESC K4 K3 S2 S33 S34 13 23 A1 S11 S22 14 24 A2 S12 S21 34 33 DC24V F1 K4 K3 DC0V 13 14 ESC K4 K3 S2 S3 1 2 HS5D 12 Safety Switch HR1S AF Safety relay module S33 S34 13 23 A1 S11 S22 14 24 A2 S12 S21 22 21 12 11 34 33 22 21 S1 HS5D 12 Safety Switch S2 Starting Switch HW Series Momentary S3 Safety limit Switch ESC Outside start condition K3 4 Safety Contactor F1 Outside fu...

Страница 5: ...sole responsibility that the product Description Safety Switch Model No HS5D to which this declaration relates is in conformity with the EC Directive on the following standard s or other normative document s In case of alteration of the product not agreed upon by us this declaration will lose its validity Applicable EC Directive Low Voltage Directive 2014 35 EU Machinery Directive 2006 42 EC Appli...

Отзывы: