B-1902-1(0)
INSTRUCTION SHEET - HS5D Series
Safety Switch
( 4 / 5 )
2016.08
Applicable Cable Glands
• Use a cable gland with a degree of
protection IP67.
• Applicable cable gland dimensions
• When using plastic cable gland, metal cable gland and multi-core cable
Plastic cable gland
SCS-10
□
(made by Seiwa Electric)
ST13.5
(made by K-MECS)
ST-M20X1.5
(made by K-MECS)
Gland port size
G1/2
PG13.5
M20
Metal cable gland
ALS-16
□□
(made by Nihon Flex)
ABS-
□□
PG13.5
(made by Nihon Flex)
ALS-
□□
EC20
(made by Nihon Flex)
• When using flexible conduit and metal cable gland
Applicable Flexible Conduit Example: Type VF-03 (made by Nihon Flex)
Plastic cable gland
G1/2
PG13.5
M20
Metal cable gland
RLC-103
(made by Nihon Flex)
RBC-103PG13.5
(made by Nihon Flex)
RLC-103EC20
(made by Nihon Flex)
Gland port size
• When using a 1/2-14NPT cable gland, use HS5D safety switch with M20 gland port
size (Type: HS5D-
□□□
BM) together with adaptor (Type: MA-M/NPT 20X1.5
5402-0110,
made by K-MECS) and gasket (Type: GP M20, made by K-MECS)
which are sold separately. Install the gasket between the safety switch and the adap-
tor. Apply a sealing tape between the cable gland and the adaptor so that the enclo-
sure will conform to IP67.
Confirm the outside diameter of the multi-core cable because the cable gland type
depends on the outside diameter of the multi-core cable.
CAUTION
30mm
maximu
m
9mm
maximu
m
G1/2, PG13.5, M20
7
Example of wiring Diagram realizing Safety Category
L1(+)
DC24V
F1
K4
K3
HS5D-12
Safety Switch
N(-)
L1(+)
N(-)
DC0V
S1
S1
12
11
HR1S-AF Safety relay module
13
14
ESC
K4
K3
S2
S33
S34
13
23
A1
S11
S22
14
24
A2
S12 S21
34
33
DC24V
F1
K4
K3
DC0V
13
14
ESC
K4
K3
S2
S3
1
2
HS5D-12
Safety Switch
HR1S-AF Safety relay module
S33
S34
13
23
A1
S11
S22
14
24
A2
S12 S21
22
21
12
11
34
33
22
21
S1: HS5D-12 Safety Switch
S2: Starting Switch (HW Series Momentary)
S3: Safety limit Switch
ESC: Outside start condition
K3, 4: Safety Contactor
F1: Outside fuse of safety relay module at power supply line
Note: Use the monitoring device(Safety relay module) provided the capavility to
detect a cross short circuit. The insulation of the cable has to withstand
environmental influences. If a control device other than the one shown in the
draft is used, the used control device has to be equipped with a cross short
circuit monitor.
Example of a circuit diagram for Safety Category 4
(attainable PL = e)
Example of a circuit diagram for Safety Category 3
(attainable PL = d)
(Condition 1: To apply he fault exclusion of mechanical structural parts including he actuator
→ Make sure to use the product within the product specification range described in this
manual and the version of the manual provided with the product.)
(Condition 2: Documentation of he reason for the machine/equipment manufacturer to have
applied the fault exclusion based on ISO13849-1, ISO13849-2 or IEC62061.)
One of the example of
the circuit ; Safety
relay module, HR1S-AF
series manufactured
by IDEC CORPORATION
One of the example of
the circuit ; Safety
relay module, HR1S-AF
series manufactured
by IDEC CORPORATION
Output Circuit
Output Circuit
Used as open/close
monitor of guard
Used as open/close
monitor of guard
Guard Open
Guard Open
HS9Z-A51 Actuator
HS9Z-A51 Actuator