background image

Safety Products

Precautions

www.idec.com   

   

USA: (800) 262-IDEC or (408) 747-0550,   Canada: (888) 317-IDEC

B1-43

B1

Safety Products

•  In order to avoid electric shock or a fire, turn the power off before 

installation, removal, wire connection, maintenance, or inspection 
of the switch. 

•  If relays are used in the circuit between the safety switch and the 

load, consider degrees of the danger and use safety relays, since 
welded or sticking contacts of standard relays may invalidate the 
functions of the safety switch.

•  Do not place a PLC in the circuit between the safety switch and the 

load. The safety security can be endangered in the event of a mal-
function of the PLC. 

•  Do not disassemble or modify the switch. It may cause a breakdown 

or an accident. 

•  Regardless of door types, do not use the safety switch as a door 

stop. Install a mechanical door stop at the end of the door to protect 
the safety switch against excessive force.

•  Do not apply an excessive shock to the switch when opening or 

closing the door.   

•  A shock to the door exceeding 1,000 m/sec

2

 (approx. 100G) may 

cause the contacts of the switch to chatter, and a malfunction of the 
switch may occur.

•  For connection of wires, unscrew the cover. Unnecessary loosening 

of other screws may cause a malfunction of the switch.

•  Prevent foreign objects such as dust and liquids from entering the 

switch while connecting a conduit or wiring.

•  If the operating atmosphere is contaminated, use a protective cover 

to prevent the entry of foreign objects into the switch through the 
actuator entry slots. 

•  Entry of a considerable amount of foreign objects into the switch 

may affect the mechanism of the switch and cause a breakdown.

•  Do not store the switches in a dusty, humid, or organic-gas atmo-

sphere.

For Rotating Head Directions

•  The head of the HS5B can be rotated in 90° increments after remov-

ing the 4 screws on the corners of the head. Prevent entry of foreign 
objects into the switch during removal of the head. Tighten these 
screws with torque designated in the instruction sheet. Improper 
torque may cause errors.

Minimum Radius of Hinged Doors

Wire Connection

•  The HS2B has 3 conduit ports, which are closed as a part of the 

molded switch housing.

•  Make an opening for wire connection by breaking one of the con-

duit-port knockouts on the switch housing using a screwdriver.

•  When breaking the conduit port, take care not to damage the con-

tact block or other parts inside the switch.

•  Cracks or burrs on the conduit entry may deteriorate the housing 

protection against water. 

•  When changing to another conduit port, close the unused opening 

with an optional plug (Type No. HS9Z-P1).

Interlock Switch Safety Precautions

Operation Precautions - for all series

HS5B Precautions

Initial

Position

Mounting in 3 Different Positions

Door Hinge

M

in

im

u

m

 R

ad

iu

s

500m

m

M

in

im

um

 R

a

dius

6

00

m

m

HS9Z-A52
Actuator

HS2B Precautions

Содержание HS1C Series

Страница 1: ...ur different circuit configurations IP67 Protection HS1C Series Full Size Interlock Switch with Locking Solenoid Direct Opening Action EN1088 EN60947 5 1 IEC60947 5 1 GS ET 15 BG standard in Germany ET Certificate No 2005010305145652 HS1C Series Functionality Conduit Port G1 2 Contact Mechanism Direct Opening Action LED Indicator Tubular Clamp Terminal Block M3 L shaped Key mainly for hinged doors...

Страница 2: ... when Locked 1 500N minimum Operating Speed 1 m sec maximum Positive Opening Travel 11 mm minimum Positive Opening Force 20N minimum Thermal Current Ith Main circuit 10A Auxiliary circuit 3A Rated Operating Current Ie Rated operating voltage Ue 30V 125V 250V Main Circuit AC Resistive load AC12 Inductive load AC15 10A 10A 10A 5A 6A 3A DC Resistive load DC12 Inductive load DC13 6A 3A 0 9A Auxiliary ...

Страница 3: ...pecial key wrench HS9Z T1 for removing the cover and manual unlocking is included with the switch 2 Specify the circuit diagram No in place of 3 Specify the indicator color R or G in place of 4 Order the key separately not included with the switch Circuit Diagram No Main Circuit Auxiliary Circuit Blank 1NC 1NC 1NO 1NO 1 1NC 1NC 1NO 2 1NC 1NC 1NC 1NC 3 1NC 1NC 1NC Circuit Diagrams 6 2 1 3 4 5 7 8 M...

Страница 4: ...sition Conduit Port G1 2 1 5 42 47 26 23 5 ø5 2 106 74 125 49 5 36 5 10 2 ø5 4 R2 7 8 5 1 0 4 35 40 Actuator Mounting Hole Layout Actuator Cover 4 M5 Screws RP 54 3 13 8 9 30 22 40 43 42 47 26 23 5 Actuator Actuator Cover Conduit Port G1 2 RP 40 43 30 6 61 36 5 10 2 106 74 42 47 1 5 125 49 5 23 5 26 ø5 2 4 35 40 17 5 1 0 11 ø5 4 R2 7 22 RP Actuator Mounting Reference Position Conduit Port G1 2 22 ...

Страница 5: ...for hinged doors The minimum radius of the door opening can be as small as 100mm For HS1 HS2 Series HS9Z A3 Accessories 2 7 4 Actuator Cover 22 6 4 4 R 3 2 30 49 3 22 2 M6 Tapped Holes Actuator Mounting Holes weight 22g Key Cover R3 2 22 40 30 20 2 11 11 5 7 4 Key Cover After installing the key remove the key cover weight 22g Stop Film Angle Adjustment M3 Hexagon Socket Head Screw Door Hinge Side ...

Страница 6: ... while connecting a conduit or wiring If the operating atmosphere is contaminated use a protective cover to prevent the entry of foreign objects into the switch through the actuator entry slots Entry of a considerable amount of foreign objects into the switch may affect the mechanism of the switch and cause a breakdown Do not store the switches in a dusty humid or organic gas atmo sphere For Rotat...

Страница 7: ...unlocked refer to the diagram on the right 1 This unlocking method is intended for an escape from a machine when a person is locked in For access to the unlocking entry an access hole should be opened on the mounting panel When opening the hole apply proper pro tection against water or other foreign objects 2 Caution After the unlocking operation put the screw back into the unlocking entry for saf...

Страница 8: ...ket head cap screws HS1B 5 0 0 5 N m approx 50 5 kgf cm 2 or 4 pcs of M5 hex socket head cap screws HS2B 5 0 0 5 N m approx 50 5 kgf cm 2 pcs of M5 hex socket head cap screws HS5B 4 0 0 4 N m approx 40 4 kgf cm 2 pcs of M4 hex socket head cap screws HS1E 5 0 0 5 N m approx 50 5 kgf cm 4 or 6 pcs of M5 hex socket head cap screws Key HS9Z A1 A2 5 0 0 5 N m approx 50 5 kgf cm 2 pcs of M6 hex socket h...