3

EB3N Safety Relay Barrier

Dimensions

        EB3N-A2ND 

EB3N-A2R5D

        EB3N-M2ND 

EB3N-M2R5D

 

Mounting Hole Layout

        EB3N-A2ND 

EB3N-A2R5D

        EB3N-M2ND 

EB3N-M2R5D

EB3N System Configuration Examples

65.0

75.0

110.5

77.5

75.0

Terminal Functions

24V DC

Power

Y1-Y2

Reset input 

(Start input)

11-12

Safety input 1

21-22

Safety input 2

N1, N2

Signal ground

P

*

-N3

Auxiliary input

13-14

Safety output 1

23-24

Safety output 2

A

*

-C1

Auxiliary output

*:

 1 to 5

2-M4 tapped or 

2-ø4.5 drilled holes

51

65

97

65

2-M4 tapped or 

2-ø4.5 drilled holes

EB3N-A2ND

Safety Control Device

Safety Control Device

Safety Control Device

Reset (Start) Switch

Other Input Device

PLC

PLC

PLC

PLC

Safety Contactor

EB3N-M2ND

Safety Contactor

Safety Contactor

Safety Contactor

Safety Contactor

Safety Contactor

Safety Input Device

Safety Input Device

Barrier Safety Output

Safety Output

Barrier Safety Output

Backcheck Input

Safety Output

Backcheck Input

Safety Output

Backcheck Input

• 

1:1 connection with a safety input device, compliant with Category 4

• 

Connection with multiple safety input devices, capable of monitoring up to 5 contact operations, compliant with Category 3

For monitoring operating statuses of safety input devices located in a non-hazardous area

• 

Installing a reset switch in a hazardous area, using auxiliary input and output

EB3N-A2R5D

Barrier Safety Output

Reset (Start) Output

Monitor

Monitor

Other Output

Barrier Safety Output

Auxiliary Output 

(Monitor Output)

EB3N-A2R5D

EB3N-M2R5D

Reset (Start) Input

Auxiliary Output 

(Monitor Output)

EB3N-M2R5D

Barrier Safety Output

Barrier Safety Output

Backcheck Input

Reset (Start) Input

Other Output

Hazardous Area

Non-hazardous Area

Hazardous Area

Non-hazardous Area

Hazardous Area

Non-hazardous Area

• A safety relay module or safety controller 

is used to set up a safety circuit, using 

the reset (start) function of the safety 

relay module or safety controller.

• The manual reset (manual start) function 

of the EB3N is used to set up a safety 

circuit, without using a safety control 

device.

• A safety relay module or safety controller 

is used to set up a safety circuit, using 

the reset (start) function of the safety 

relay module or safety controller.

• The reset (start) function is used to set up 

a safety circuit, without using a safety 

relay module or safety controller.

Safety Input Devices 

Connected in Series

Safety Input Devices

Safety Input Devices 

Connected in Series

Reset (Start) Switch

Other Input Device

Safety Input Devices

Reset (Start) Input

Backcheck Input

Reset (Start) Input

Backcheck Input

Reset (Start) Input

All dimensions in mm.