background image

Vol-Con

®

 Elite Voltage / Continuity Tester 

Instruction Sheet

 

WARNINGS

To avoid possible electric shock, personal injury, or death, follow these guidelines.

•  Do not use if tester appears damaged or is not operating properly.

•  Inspect and replace leads if insulation is damaged, metal is exposed, or probes are cracked.

•  Do not use meter if it operates abnormally as protection maybe impaired.  

•  Do not use tester for more than the rated voltage on the tester.

•  Do not use without the battery and the back case properly installed.

•  Do not apply more than the rated voltage to the meter. 

•  Do not use during electrical storms or in wet weather.

•  Do not use around explosive gas, dust, or vapor.

•  Ensure all fingers are behind finger guard when testing for voltage.

•  This tester will not detect voltages at a distance, such as through walls, metal conduit, or shielded wire.

•  Before each use perform a continuity test by touching the probe tips together, an audible sound should be 

 

heard and the continuity [•

)

)

)] LED should light.  This test verifies the functionality of the battery and test leads.

•  Use the 3 Point Safety Method.  (1) Verify tester operation by measuring a known voltage.  (2) Apply tester to circuit under test.  (3) Return to the known live voltage again to ensure proper operation.

•  Replace batteries as soon as low battery indicator appears.

•  If this tester is used in a manner not specified by IDEAL, protection provided by the product may be impaired.

•  Comply with local and national safety requirements, including the use of appropriate personal protective equipment.

Features: 

•  Non-Contact Voltage Sensor (40-600VAC) 

•  Audible and LED Indication of Voltage Levels 

•  Low Impedance Measuring Device

•  Vibration Mode (61-092)  

•  Auto-Switching Voltage/Continuity Technology 

•  Replaceable Silicone Test Leads

To Measure Voltage (AC

~

/DC   

     

):

•  Place the black test lead into the “COM” input and the red test lead into the “V+” input on the tester.

•  Connect the tester in parallel with the load or circuit.

•  The tester will automatically turn on, indicating both the voltage type and the voltage level.

To Test for Continuity:

•  Place the black test lead into the “COM” input and the red test lead into the “V+” input on the tester.

•  De-Energize circuit before performing continuity test.  Note, if voltage is present in the circuit, the tester will automatically switch to voltage indication mode.

•  Test for continuity by connecting the meter to the circuit.

•  If circuit is complete, an audible indication will be heard and the [•

)

)

)] LED lights green.

•  Continuity is indicated at less than 20

Ω

To Use The Non-Contact Voltage (NCV) Sensor:

•  The non-contact voltage sensor protrudes from the top of the tester.

•  While placing the sensor near the circuit to be tested, press the button labeled “NCV”.

•  If 40 to 600 VAC is present, an audible indication will be heard and the “NCV” LED lights.

•  The closer the NCV sensor is to the AC voltage, the louder the beep.

•  To differentiate between the hot and neutral in an outlet, insert the tab into each slot of the outlet.  The beeper will be louder on the hot side of the outlet rather than 

 

the neutral.

•  The red test lead can also be used to further differentiate between the hot and neutral.  Insert the red test lead into the “V+” input of the tester, slide the red probe into test 

 

probe holder.  While pressing the “NCV” button, insert the red probe into the outlet.  The beeper will sound and the “NCV” LED will light on the hot side of the outlet. 

Shaker Function (61-092)

•  Tester starts shaking at 30VAC.

•  The tester shakes at an increasingly variable level that allows the user to differentiate between 60V, 120V, 240V, and 480 VAC.

Low Battery Indicator:

The          •

)

)

) LED will flash red if battery voltage is low when checking circuit voltage or continuity.  Replace batteries immediately to ensure reliable performance.

Battery Replacement

1.  Disconnect test leads from any live source and remove the test leads from the input terminals.

2.  The battery cover is secured to the bottom case by two screws.  Using a Phillips-head screwdriver, remove the screws from the battery cover and remove the battery cover.

3.  Remove battery and replace with four new 1.5 volt (AAA size) batteries.

4.  Replace the battery cover and reinstall the screws.

Maintenance:

Clean with a damp cloth and mild detergent.  If the tester acts erratically, or the         flashes red, change the batteries.

Service and Replacement Parts:

There are no user-serviceable parts. To inquire about service information, contact IDEAL INDUSTRIES, INC. at 877-201-9005, or visit our website at www.testersandmeters.com.  

Test Leads - TL-102 

Soft sided carrying case  -  C-90

Specifications:

VAC Ranges:   

24V, 120V, 208V, 240V, 277V, 480V, 600V. (45Hz ~ 66Hz) 

Over-range Indication: 

Over 600V

~

 or 220V      , All LED’s will light up 

VAC Accuracy:    70% to 100% of the LED labeled voltage 

Operating Environment: 

32°F to 122°F (0 to 51°C) at <70% R.H. 

 

88% to 100% of the LED labeled voltages of 240V and 277V 

Storage Temp.: 

-4°F to 140°F (-20 to 60°C) at <80% R.H. 

 

80% to 100% of the LED labeled 600V 

Altitude: 

Up to 6561.7 feet (2000m)

VDC Ranges:   

6V, 12V, 24V, 36V, 48V, 110V, 220V 

Battery: 

AAA (LR03) size, 1.5V      x4, 120mA

VDC Accuracy:  70% to 100% of the LED labeled voltage 

Battery Life:   

200 hours typical on 61-090; 100 hours typical on 61-092

 

80% to 100% of the LED labeled voltage of 48V 

Accessories included:   

Test Leads, (4) 1.5V       “AAA” batteries, operating

Continuity: 

Continuous LED and audible indication at less than 20k

Ω

 

  

instructions

 

Response time of 100ms 

Dimensions:    

7.8”(L) x 1.7”(W) x 1.5”(D), 199m(L) x 44m(W) x 39m(D) 

Input Inpedance:    1M

Ω

 

Weight: 

6.3 oz. (180g)

Overload Protection:  1000VDC/750VAC rms 

Safety:   

Complies with UL-61010, EN61010, Cat III-1000V 

 

Equipment protected by double insulation. 

Instrument complies with insulation overvoltage category III.  Cat III equipment is designed to protect against transients from primary supply level.  Pollution degree 2 in accordance with 

IEC-664. Indoor use.

WARRANTY STATEMENT

This tester is warranted to the original purchaser against defects in material and workmanship for two years from the date of purchase. During this warranty period, IDEAL INDUSTRIES, INC. will, at its option, 

replace or repair the defective unit, subject to verification of the defect or malfunction. 
This warranty does not cover fuses, batteries or damage from abuse, neglect, accident, unauthorized repair, alteration, or unreasonable use of the instrument.
Any implied warranties arising out of the sale of an IDEAL product, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the above. The manufacturer 

shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expenses or economic loss.
State laws vary, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

 

#61-090  NCV

#61-092  NCV, Shaker

+

+

+

N12966