background image

 

INSTALLING DOWNROD ASSEMBLY 

 

1.  Inset the downrod assembly to canopy and 

downrod cover. 

2.  Inset the downrod assembly to switch box. 
3.  Inset the bolt across the downrod and rod 

base. 

4.  Fix and firmly tighten the washer, nut and slot 

the cotter pin. 

5.  Tighten the set screw of the downrod base to 

downrod. 

6.  Put the upper canopy down through the 

downrod. 

HANGING THE FAN 

 
Lift the fan assembly onto the mounting bracket. Ensure 
the registration slot (A) of the hanger ball is positioned 
on the stopper (B) of the mounting bracket (C) to prevent 
the fan from rotating when in operation.

 

Содержание Seattle DC Series

Страница 1: ...pictured is for illustration purposes only Styles may vary according to the specific models Ceiling Fan Installation Manual Rev 1 0 Seattle DC series Model SEA1403LO DC SEA1403WN DC INSTALLATION OPERA...

Страница 2: ...standard Please note warranty will be void if installation is without an all pole disconnection incorporated in the fixed wiring in accordance with the wiring rules Example If a fan is connected to a...

Страница 3: ...efer to Fig 1 Parts List QTY 1 Hanging Bracket 1 2 Downrod Assembly 1 3 Upper Canopy 1 4 Downrod Cover 1 5 Switch Housing 1 6 Upper Housing 1 7 Motor Assembly 1 8 Motor Bracket 1 9 Blade 3 10 Lower Ho...

Страница 4: ...eiling joist or structure that is capable of carrying a load of at least 30kg with the two long screws provided Ensure at least 30mm of the screw is threaded into the support NOTE The bracket screws p...

Страница 5: ...and firmly tighten the washer nut and slot the cotter pin 5 Tighten the set screw of the downrod base to downrod 6 Put the upper canopy down through the downrod HANGING THE FAN Lift the fan assembly...

Страница 6: ...PORATED IN THE FIXED WIRING IN ACCORDANCE WITH THE WIRING RULES Connect LIVE supply wire to the L of the terminal block on the mounting bracket Connect NEUTRAL supply wire to the N of the terminal blo...

Страница 7: ...py to fan body BLADE INSTALLATION BLADE ATTACHMENT Unscrew the blade mounting screws on motor bracket and keep carefully for following 1 Tighten the Blades with Screws kept just now Each Blade uses 3...

Страница 8: ...h means learning successfully and it can works normally PS Learning mode is not accepted after turn ON the supply power for 30 seconds 1 F R button Press F R button to set up ceiling fan operate in fo...

Страница 9: ...ear during this time Please note that this is not a product fault and as such is not covered under warranty All electric motors are audible to some extent CARE AND CLEANING Periodic cleaning of your c...

Страница 10: ...tenance can reduce or prevent this problem Night Noises This is the biggest cause of service calls which are outside the manufacturer s warranty If a fan has a fault then it would be noticeable at ALL...