Frost protection

This is provided automatically by the boiler control unit.  If  frost is
likely during an absence from home, turn the boiler off at the time
switches ONLY, leaving the mains supply switched ON.

If the boiler flow temperature falls below 7 

o

C the pump will run,

without the boiler firing, until the temperature exceeds 10 

o

C.

If the flow temperature falls below 3 

o

C the boiler will fire until the

temperature exceeds 10 

o

C.

Fault condition

If the boiler will not light initially or if a fault develops during normal
operation, the first digit and the last 2 digits of the display will flash
alternately. In this event press the RESET button and the boiler
will recommence the ignition cycle.

If the fault condition persists, turn the boiler OFF and consult your
local registered installer.

Loss of system water pressure

The gauge (E) on the control panel indicates the central heating
system pressure.  If the pressure is seen to fall below the original
installation pressure of 1-2 bar over a period of time then a water
leak is indicated. In this event consult your local registered installer.

DO NOT OPERATE THE BOILER IF THE PRESSURE HAS
REDUCED TO ZERO FROM THE ORIGINAL SETTING.

Escape of gas

Should a gas leak be suspected contact your local gas supplier
IMMEDIATELY.

Do NOT search for gas leaks with a naked flame.

Condensate drain

The condensate drain must NOT be modified or blocked.

Blockage caused by debris or freezing can cause automatic
shutdown of the boiler.

If freezing is suspected and the pipe run is accessible, an attempt
may be made to free the obstruction by pouring hot water over the
exposed pipe and clearing any blockage from the end of the pipe.
If this fails to remedy the problem seek advice from your local
registered installer.

Cleaning

For normal cleaning simply dust with a dry cloth.
To remove stubborn marks and stains, wipe with a damp cloth
and finish off with a dry cloth.
DO NOT use abrasive cleaning materials.

Maintenance

The appliance should be serviced at least once a year by a
registered installer, local gas authority or registered service
organisation.

Note. 

In the normal running STANDBY mode, the left hand

display digit indicates the boiler sequence and the other 2
digits the boiler flow temperature.

Sequence

Boiler Status

0

Standby - no heat request

1

Purge

2

Ignition

3

Burner on - CH

4

Burner on - DHW

6.

Close the controls door.

Operation

WINTER CONDITIONS - i.e. CH and DHW required.

Set the CH switch (D) to ON.

The boiler will fire and supply heat to the radiators but will give
priority to DHW on demand.

The DHW preheat will operate as described under 'Summer
conditions' during periods when there is no call for CH.

SUMMER CONDITIONS - i.e. DHW only required.

Set the CH switch (D) to OFF.

The boiler will fire for approximately one minute, to preheat the
DHW heat exchanger and thereafter fire periodically for a few
seconds in order to maintain the temperature.

Control of water temperature

DOMESTIC HOT WATER

The DHW temperature is limited by the boiler controls to 60 

o

C

maximum at low draw-off rate.

Additionally, the temperature is controlled by the user via the
draw-off tap : the lower the rate the higher the temperature, and
vice versa.

CENTRAL HEATING

The boiler controls the central heating radiator temperature to a
maximum of 82 

o

C

DOMESTIC HOT WATER & CENTRAL HEATING

To return the boiler to normal running STANDBY mode press the
RESET button.

To shut down the boiler

1. For short periods

Set the CH switch (D) to OFF.

2. For longer periods

Set the on/off switch (C) and CH switch (D) to OFF, and switch
the electricity supply to OFF.

THE LOG BOOK SHOULD BE COMPLETED AFTER

EACH SERVICE AND KEPT WITH THESE

INSTRUCTIONS

Содержание Response SE

Страница 1: ......

Страница 2: ...tions before the boiler is fitted and it fits inside a cupboard Its compact size makes the Response SE ideal for any kitchen It can be installed inside a cupboard without any ventilation Response SE T...

Страница 3: ...Appliance No 47 348 03 Gastec Certified P I No 0063 AS 3355 Destination Countries GB IE CAUTION To avoid the possibility of injury during the installation servicing or cleaning of this appliance care...

Страница 4: ...ly the boiler and system controls The means of isolation must be accessible to the user after installation The fusing should be 3A Legend A Control door B Control panel C On off switch D Central heati...

Страница 5: ...k advice from your local registered installer Cleaning For normal cleaning simply dust with a dry cloth To remove stubborn marks and stains wipe with a damp cloth and finish off with a dry cloth DO NO...

Страница 6: ...92 251Fax 01482448858 RegistrationNo London322 137 RegisteredOffice NationalAvenue Kingstonupon Hull HU54JN AsubsidiaryofCaradonp l c The code of practice for the installation commissioning servicing...

Страница 7: ...be giving away a free boiler for the five best ideas every year to be selected by our Technical Director Please complete this form using extra sheets if required and post it or fax it to us on 01482 4...

Страница 8: ...ease arrange for me to join an Ideal factory tour Range guides required The Ideal Guide a specifier s and installer s introduction to the Ideal domestic boiler range The Ideal Householders Guide to as...

Отзывы: