IDEAL Mexico Super 40 FF Скачать руководство пользователя страница 4

4

Mexico Super FF - Users

Safety

It is essential that the instructions in this booklet are
strictly followed, for safe and economical operation of
the boiler.

Gas Safety (Installation & Use) Regulations 1994
and Amendments 1996.

 In your own interest, and

that of safety, it is the law that this boiler must be
installed by a registered installer, in accordance with
all national and local regulations.

Electricity Supply

This appliance must be efficiently earthed.

Supply: 230 V ~ 50 Hz.

The fusing should be 3A.

Connection must be made in a way that allows complete
isolation of the electrical supply such as a double pole switch
having a 3mm (1/8") contact separation in both poles, or a
plug and socket, serving only the boiler and system controls.
The means of isolation must be accessible to the user after
installation.

NOTE TO THE INSTALLER:

  

 LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER

1 BOILER CLEARANCES

Important Points

a.

If the boiler is installed in a compartment then the
compartment MUST NOT be used for storage purposes.

b.

The ventilation provided for the boiler during installation MUST
NOT be blocked, and a check should be made periodically
that the ventilation areas are free from any obstruction.

c.

If it is known or suspected that a fault exists on the boiler then
it MUST NOT be used until the fault has been corrected by a
CORGI registered installer.

d.

Inflammable materials must not be placed in close proximity
to the appliance.  Materials giving off  flammable vapours
must not be stored in the same room as the appliance.

e.

Under NO circumstances should any of the sealed
components on this appliance be used incorrectly or tampered
with.

In cases of repeated or continuous shutdown a CORGI registered
person should be called to investigate and rectify the condition
causing this and carry out an operational test after each
intervention on the device.  Only the manufacturer's original parts
should be used for replacement.

Minimum Clearances

A clearance of 533mm (21") MUST be available at the front of the
boiler for servicing.

The minimum clearances given in Table 1 MUST be complied
with, in order to maintain the safe running of the boiler.

Table 1

Boiler

Flue

Dimension A

Model

Length

Rear Flue

Side/Top flue

mm (in.)

mm (in.)

mm (in.)

40 FF, 50 FF

Up

10

35

60 FF, 70 FF

to

(

3/8

)

(1 

3/8

)

80 FF, 100 FF

600

125 FF

(23 

5/8

)

55 (2 

1/4

)

55 (2 

1/4

)

40 FF, 50 FF

600 to

60 FF, 70 FF

3000

35

35

80 FF

(23 

5/8

 to

(1 

3/8

)

(1 

3/8

)

118)

100 FF

600 to 2000

35

35

(23 

5/8

 to

(1 

3/8

)

(1 

3/8

)

78 

3/4

)

125 FF

600 to

1000

55

55

(23 

5/8

 to

(2 

1/4

)

(2 

1/4

)

39 

1/4

)

Содержание Mexico Super 40 FF

Страница 1: ......

Страница 2: ...e and 8 propane Super models and 7 Fanned models Option kit availability includes an easy to use programmer kit available on all models an overheat thermostat kit for all models and a pump kit that ca...

Страница 3: ...9 80 Mexico Super 70 FF G C No 41 349 81 Mexico Super 80 FF G C No 41 349 82 Mexico Super 100 FF G C No 41 349 83 Mexico Super 125 FF G C No 41 349 84 Mexico Super Natural Gas Models Only Certified P...

Страница 4: ...ilation areas are free from any obstruction c If it is known or suspected that a fault exists on the boiler then it MUST NOT be used until the fault has been corrected by a CORGI registered installer...

Страница 5: ...system should be drained including the domestic water supply If the system includes a frost thermostat then during cold weather the boiler should be turned OFF at the time switch if fitted ONLY The ma...

Страница 6: ...T Manufactured under a BS EN ISO 9001 1994 Quality System accepted by BSI Caradon Plumbing Ltd pursues a policy of continuing improvement in the design and performance of its products The right is the...

Страница 7: ...ll be giving away a free boiler for the five best ideas every year to be selected by our Technical Director Please complete this form using extra sheets if required and post it or fax it to us on 014...

Страница 8: ...nical representative to contact me Please arrange for me to join an Ideal factory tour Range guides required The Ideal Guide a specifier s and installer s introduction to the Ideal domestic boiler ran...

Отзывы: