Mexico Super FF - Users
Safety
It is essential that the instructions in this booklet are
strictly followed, for safe and economical operation of
the boiler.
Gas Safety (Installation & Use) Regulations 1994
and Amendments 1996.
In your own interest, and
that of safety, it is the law that this boiler must be
installed by a registered installer, in accordance with
all national and local regulations.
Electricity Supply
This appliance must be efficiently earthed.
Supply: 230 V ~ 50 Hz.
The fusing should be 3A.
Connection must be made in a way that allows complete
isolation of the electrical supply such as a double pole switch
having a 3mm (1/8") contact separation in both poles, or a
plug and socket, serving only the boiler and system controls.
The means of isolation must be accessible to the user after
installation.
NOTE TO THE INSTALLER:
LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER
1 BOILER CLEARANCES
Important Points
a.
If the boiler is installed in a compartment then the
compartment MUST NOT be used for storage purposes.
b.
The ventilation provided for the boiler during installation MUST
NOT be blocked, and a check should be made periodically
that the ventilation areas are free from any obstruction.
c.
If it is known or suspected that a fault exists on the boiler then
it MUST NOT be used until the fault has been corrected by a
CORGI registered installer.
d.
Inflammable materials must not be placed in close proximity
to the appliance. Materials giving off flammable vapours
must not be stored in the same room as the appliance.
e.
Under NO circumstances should any of the sealed
components on this appliance be used incorrectly or tampered
with.
In cases of repeated or continuous shutdown a CORGI registered
person should be called to investigate and rectify the condition
causing this and carry out an operational test after each
intervention on the device. Only the manufacturer's original parts
should be used for replacement.
Minimum Clearances
A clearance of 533mm (21") MUST be available at the front of the
boiler for servicing.
The minimum clearances given in Table 1 MUST be complied
with, in order to maintain the safe running of the boiler.
Table 1
Boiler
Flue
Dimension A
Model
Length
Rear Flue
Side/Top flue
mm (in.)
mm (in.)
mm (in.)
40 FF, 50 FF
Up
10
35
60 FF, 70 FF
to
(
3/8
)
(1
3/8
)
80 FF, 100 FF
600
125 FF
(23
5/8
)
55 (2
1/4
)
55 (2
1/4
)
40 FF, 50 FF
600 to
60 FF, 70 FF
3000
35
35
80 FF
(23
5/8
to
(1
3/8
)
(1
3/8
)
118)
100 FF
600 to 2000
35
35
(23
5/8
to
(1
3/8
)
(1
3/8
)
78
3/4
)
125 FF
600 to
1000
55
55
(23
5/8
to
(2
1/4
)
(2
1/4
)
39
1/4
)