IDEAL Henrad WH LX30FF Скачать руководство пользователя страница 3

Supplied By www.heating spares.co  Tel. 0161 620 6677

3

Henrad WH LXFF & FF - 

User's

WH LX FF & FF 

 (

Natural Gas Models Only)

PI No. 87AP107

Minimum clearances

A clearance of 533mm (21") MUST be available at the front of the
boiler for servicing.

The minimum clearances given below MUST be complied with
in order to maintain the safe running of the boiler and to
facilitate servicing.

Above the boiler

100 mm

(4")

At each side of the boiler

5 mm

(

1/4

")

Underneath the boiler

100 mm

(4")

In front of the boiler

450 mm

(17 

3 /4

 ")

Introduction

It is essential that the instructions in this booklet are
strictly followed, for safe and economic operation of
the boiler.

Gas Safety (Installation & Use) Regulations 1994,
amendments 1996, or the rules in force.

In your own interest, and that of safety, it is the law that this
boiler must be installed by a registered installer, in accordance
with all national and local regulations.

Electricity Supply

This appliance must be efficiently earthed.

Supply: 230 V ~ 50 Hz. 

The fusing should be 3A.

Connection must be made in a way that allows complete
isolation of the electrical supply such as a double pole
switch having a 3mm (

1/8

") contact separation in both

poles, or a plug and socket, serving only the boiler and
system controls. The means of isolation must be
accessible to the user after installation.

Important notes

a.

This appliance must not be operated without the casing
correctly fitted and forming an adequate seal.

b.

If the boiler is installed in a compartment then the
compartment MUST NOT be used for storage purposes.

c.

The ventilation provided for the boiler during installation
MUST NOT be blocked, and a check should be made
periodically that the ventilation areas are free from any
obstruction.

d.

If it is known or suspected that a fault exists on the boiler
then it MUST NOT be used until the fault has been
corrected by a CORGI registered installer.

e.

Inflammable materials must not be placed in close
proximity to the appliance.  Materials giving off flammable
vapours must not be stored in the same room as the
appliance.

f.

Under NO circumstances should any of the sealed
components on this appliance be used incorrectly or
tampered with.

CAUTION. 

 

To avoid the possibility of injury during the installation, servicing or cleaning

of this appliance care should be taken when handling edges of sheet steel components

Standard

Deluxe

WH

 30 FF .............................. G.C. No. 41 349 87

WH

 40 FF .............................. G.C. No. 41 349 88

WH

 50 FF .............................. G.C. No. 41 349 89

WH

 60 FF .............................. G.C. No. 41 349 90

WH

 70 FF .............................. G.C. No. 41 349 91

WH

 80 FF .............................. G.C. No. 41 349 92

WH  100 FF ............................. G.C. No. 41 349 93

WH

LX 30 FF ................ G.C. No. 41 349 94

WH

LX 40 FF ................ G.C. No. 41 349 95

WH

LX 50 FF ................ G.C. No. 41 349 96

WH

LX 60 FF ................ G.C. No. 41 349 97

WH

LX 70 FF ................ G.C. No. 41 349 98

WH

LX 80 FF ................ G.C. No. 41 349 99

Содержание Henrad WH LX30FF

Страница 1: ...Supplied By www heating spares co Tel 0161 620 6677 ...

Страница 2: ...Supplied By www heating spares co Tel 0161 620 6677 2 Henrad WH LXFF FF User s ...

Страница 3: ...on must be accessible to the user after installation Important notes a This appliance must not be operated without the casing correctly fitted and forming an adequate seal b If the boiler is installed in a compartment then the compartment MUST NOT be used for storage purposes c The ventilation provided for the boiler during installation MUST NOT be blocked and a check should be made periodically t...

Страница 4: ...thermostat to the desired position 8 Deluxe Model LX Lower the glass fascia after pushing in the sliding catch Standard Model Close the controls access door In winter conditions i e central heating and domestic hot water the thermostat should be set at position 5 or 6 For summer conditions i e domestic hot water only the thermostat should be set at position 3 These settings however are offered for...

Страница 5: ...oiler is fitted with a safety cutout thermostat This will shut down the boiler in the event of overheating Should this occur allow the boiler to cool press the reset button D then relight as detailed in steps 1 8 in To light the boiler If the cutout condition still persists turn off the boiler and consult a CORGI registered installer Control of water temperature 1 Adjust the boiler thermostat C to...

Страница 6: ...ASSURANCE OF QUALITY These appliances are designed for use with Natural Gas only They have been tested and conform with the provisions of BS 6332 and BS 5258 LXFF 87 AQ 220 LXRS 87 AQ 221 FF 87 AP 107 RS 87 AP 108 Natural Gas appliances are service listed by British Gas CERTIFIED PRODUCT Manufactured under a BS EN ISO 9001 1994 Quality System accepted by BSI The code of practice for the installati...

Страница 7: ...ow to improve our boilers and our service We will be giving away a free boiler for the five best ideas every year to be selected by our Technical Director Please complete this form using extra sheets if required and post it or fax it to us on 01482 498699 Boiler details Model Size details on control panel door Date of Installation Installer details Name Address Post Code Telephone Please include S...

Страница 8: ...nclude STD code General information required Please send me details of Henrad Training Courses Please arrange for a technical representative to contact me Please arrange for me to join an Henrad factory tour Range guides required The Henrad Guide a specifier s and installer s introduction to the Henrad domestic boiler range The Henrad Householders Guide to assist the installer when presenting to h...