background image

3

5

 EXALT Combi 199 Burner Components

7

5

3

6

4

2

9

13

11

12

10

8

1

Item

Part #

Description

1

EXARKIT05

Blower Assembly

2

EXARKIT27

Ignitor Assembly

3

EXARKIT32

Burner Plate Insulation

4

EXARKIT87

Sight Glass Assembly

5

EXARKIT16

Burner Plate

6

EXARKIT20

Combustion two in one Insulation

7

EXARKIT25

Burner Head Assembly

8

EXARKIT11

Venturi (NG)

8

EXARKIT12

Venturi (LP)

9

EXARKIT06

Gas Valve

10

EXARKIT13

Venturi Air Inlet

11

EXARKIT74

Air Inlet Elbow

12

EXARKIT75

Air Inlet Adaptor

13

EXARKIT78

Venturi Gas Valve Inlet Pipe

It is essential to ensure 

during installation, main-

tenance or repair that 

items 12, 11 and 10 are 

correctly fitted between 

the blower and inlet 

adaptor.  Failure to ensure 

correct fitting may result 

in serious injury, or death.

 EXALT Combi 199 Burner Components

7

5

3

6

4

2

9

13

11

12

10

8

1

Item

Part #

Description

1

EXARKIT05

Blower Assembly

2

EXARKIT27

Ignitor Assembly

3

EXARKIT32

Burner Plate Insulation

4

EXARKIT87

Sight Glass Assembly

5

EXARKIT16

Burner Plate

6

EXARKIT20

Combustion two in one Insulation

7

EXARKIT25

Burner Head Assembly

8

EXARKIT11

Venturi (NG)

8

EXARKIT12

Venturi (LP)

9

EXARKIT06

Gas Valve

10

EXARKIT13

Venturi Air Inlet

11

EXARKIT74

Air Inlet Elbow

12

EXARKIT75

Air Inlet Adaptor

13

EXARKIT78

Venturi Gas Valve Inlet Pipe

It is essential to ensure 

during installation, main-

tenance or repair that 

items 12, 11 and 10 are 

correctly fitted between

the blower and inlet 

adaptor.  Failure to ensure 

correct fitting may result 

in serious injury, or death.

Содержание EXALT COMBI

Страница 1: ...1 Quick Reference Boiler Piping and Wiring Guide EXALT COMBI AND SOLO...

Страница 2: ...Certified 50 PSI Maximum working pressure VENTING 2 Vent Exalt 110 155 up to 28 3 Vent all models up to 100 3 in 1 Universal vent adapter directly accepts PVC Polypropylene and Stainless Steel COMBI F...

Страница 3: ...Quick Reference Boiler Piping and Wiring Guide COMBI BOILERS COMBI USING A LOW LOSS HEADER COMBI USING CLOSELY SPACED TEES See appendix for listing of additional components 3...

Страница 4: ...M ON ON OFF CH 2 ON ON OFF DtilW OfF Oti ON No Pump Setting C hanges Needed WithThis Configuration CH2 System Thermostat Sensor 6 5 4 3 X5 f f S S S S Modulation Signal 2 1 f S S CH1 Outdoor Thermost...

Страница 5: ...tit 1 ON ON OFF CH 2 ON ON OFF Dti W Off On ON No Pump Setting Changes Needed With This Configuration CH2 System Modulation CH1 Outdoor DHW Modbus Thermostat Sensor 6 5 4 3 X5 0 0 0 0 Signal 2 1 0 0 T...

Страница 6: ...PUMPS BOIUE PUMP SETTIN G HeatC II FLAME CH PUMP CH 1 QN ON CH 2 QN ON IOHW ofF On No Pump Setting Changes Needed With This Configuration I I I I r I I I I IDKWPUMP OFF OFF ON OJ cbor Sensor DHW Sens...

Страница 7: ...ON 0 DHW Off On No Pump Setting Changes Needed With This Configuration ___I I I I I I 0 000 00 L 7 I I I I I I I I Quick Reference Boiler Piping and Wiring Guide DlfWPUIM_P OFF OFF ON OJtcbor Sensor...

Страница 8: ...CH 2 ON OFF ON IJHW OFF On Pump Setting Change s Needed With This Configuration CH2 Thermo sta 6 5 Syslem Modulati Sensor Signal 4 3 2 1 CH1 Outdoor Thermosta Sensor 4 3 2 1 DHW Sensor o Pquasta 2 1...

Страница 9: ...In U i411 1 UP illr IIII C 1111713 Oll IIU l H 1 IC IIQU M lilt __ i1 11Ci 1WI LD u1 711re iXilH UI _ n w c 1 1 IIQ _ IS f Ulll M I 111 L e OM R 1 IYT 11 liGN I n l ll tUtoe r IIQlll 11 is lUGl d 1 n...

Страница 10: ...OFF C HPIUMP ON ON OFF DHWPUMP 0 FIF OFIF ONI No Pump Setting Changes Needed With This Configuration CH2 System Thermostat Sensor 6 5 4 3 X5 f c n S S S S Modulation Signal 2 1 n c S S CH1 Outdoor Th...

Страница 11: ...flF CI H ON ONI OFF DHW OFF OF F ON No Pump Setting Changes Needed With This Configuration CH2 System Thermostat Sensor 6 5 4 3 0 0 0 0 Modulation Signal 2 1 l 0 0 CH1 Outdoor Thermostat Sensor 4 3 2...

Страница 12: ...N OHW OFF OFF ON Pump Setting Changes Needed With This Configuration DHWPUMP OFF OFF ON MaluBIDn Themnstat CH2 I 6 5 00 m 1 4 3 00 ma J Sgrel 2 00 f El Q Q I I I I T l PRK lRITY ltfl lT Z0flE4 120VAC...

Страница 13: ...Orf ON ON Pump Setting Changes Needed With This Configuration CH2 System I Therrmstat Sensor or 6 5 4 3 2 1 1 j f 1 I r 1 I I r 1 I I I I PRORITY Z0flE2 ZOIIEJ ZOIIE4 1234 1234 1234 000000000000000 I...

Страница 14: ...ll CH 1 CH 2 OHW SOIL ER PUMP Sl liTl G fl tME 0 0 OFF CH Pl IMP ON 01 1 OFF OHWPUMP OfF OfF ON No Pump Setting Changes Needed With This Configuration E Q Q I I I I _I_ T J PRORITY IWUT zm 1 4 12ovN N...

Страница 15: ...IMP OI IWPUMP CH 1 0 0 OfF Ctl 2 ON ON OFF OI IW OFF Orf ON ON Pump Setting Changes Needed With This Configuration R l JJ NS gleWireFmmK To LTermrlalOnlheFi imeOJtp JI Rerrnve pe From ONLY For DHW Pri...

Страница 16: ...CH PUMP 0 ON ON OFF OFF 01 OFF ON DHWPU P OFF OFF ON Pump Setting Changes NeededWith This Configuration SRSOl4 OtEZOtE WITCHNG FE LAY Power 120VAC Water Supply High Temp Dl 2 I I CH2 S stem MaluB rm...

Страница 17: ...DHWPUMP OFF OFF ON No Pump Setting Changes Needed With This Configuration CH2 System Ma lulatl n Themnstat Sensor Signal 0 0 0 0 0 0 i I uuQQQQ I I I I I I I N H 00 r r r SR 506 4 0 Quick Reference B...

Страница 18: ...ng Changes Needed With This Configuration Pump Settings Need To Be Changed On All Boilers Note Communication CableNeeded For Each Follower Boiler DHWPUMP Off Off 00 R W ZONE PRIORITY F PRIORITY INPUT...

Страница 19: ...L_ _e L Main Control I Board L System Sensor COMMUNICATION CABL PART GACAB0l Relay Outdocr DHW End Switch Sensor Sensor COMMUNICATION CABL PART GACAB0l Back of Display Panel B 2 I I I I i I I I i Back...

Страница 20: ...allant 399 72 500 399 000 NA 786164 Based on a 70 Degree Rise and all boilers ship with a LP conversion ki Maximum Vent Length Beiler Modets 2 PVC CPVC PP 3 PVC CPVC 1PP 1 10 28 1 55 1199 NA Equivalen...

Страница 21: ...Integrated boiler connections Plugged FIP ports PATENTED TECHNOLOGY Quicker consistent quality installation Fewer leak paths Allows for easy cleaning or flushing of system Allows for one person diagn...

Страница 22: ...Sweat BoilerTrim Kits PROPPBTK 1DLXS S80960 1 Deluxe Sweat BoilerTrim Kit PROPPBTK 114DLXS S80961 1 1 4 Deluxe Sweat BoilerTrim Kit PurePro Deluxe IPS BoilerTrim Kits PROPPBTK 1DLX 31648S 1 Deluxe IPS...

Страница 23: ...appliance manufacturer for condensate As a guideline 500 000 BTU hr at 93 efficiency will produce approximately 1 9 Gal hr 4 1041 e Specifications The condensate neutralization tank with pump shall b...

Страница 24: ...3 576 5 2 1 Exalt Solo 110 155 199 Exalt Combi 155 199 25...

Страница 25: ...replacement parts to ensure warranty coverage and to avoid improper operation or damage to appliance Contact Ideal at 800 411 9999 or www idealusa com for a list of distribu tors near you WARNING Ite...

Страница 26: ...g Bracket with Hardware 5 EXJKT06 Right Side Jacket Panel 6 EXARKIT91 User Interface Mounting Bracket EXALT Combi Jacket Components 1 3 2 5 4 6 Item Part Description 1 EXJKT04 Front Jacket Panel 2 EXA...

Страница 27: ...ensor 6 EXARKIT85 Condensate Drain Assembly 7 EXARKIT41 Flue Tube 8 EXARKIT57 Flue Temperature Sensor EXALT Solo 110 Internal Components 4 4 5 6 6 5 7 8 1 3 3 2 Item Part Description 1 EXARKIT40 Vent...

Страница 28: ...IT40 Vent Outlet Combustion Air Inlet Adapter 2 EXARKIT02 Heat Exchanger Body 3 EXARKIT56 CH Supply Temperature Sensor 4 EXARKIT59 Low Water Cut Off 5 EXARKIT56 CH Return Temperature Sensor 6 EXARKIT8...

Страница 29: ...nsate Drain Assembly 7 EXARKIT41 Flue Tube 8 EXARKIT21 Circulator 9 EXARKIT57 Flue Temperature Sensor EXALT Combi 155 Internal Components 7 4 5 8 6 1 3 2 9 7 Item Part Description 1 EXARKIT40 Vent Out...

Страница 30: ...ensor 6 EXARKIT85 Condensate Drain Assembly 7 EXARKIT41 Flue Tube 8 EXARKIT57 Flue Temperature Sensor EXALT Solo 199 Internal Components 1 2 3 4 5 7 6 6 8 Item Part Description 1 EXARKIT40 Vent Outlet...

Страница 31: ...nsate Drain Assembly 7 EXARKIT41 Flue Tube 8 EXARKIT21 Circulator 9 EXARKIT57 Flue Temperature Sensor EXALT Combi 199 Internal Components 1 7 2 3 4 5 8 6 9 Item Part Description 1 EXARKIT40 Vent Outle...

Страница 32: ...the blower and inlet adaptor Failure to ensure correct fitting may result in serious injury or death EXALT Solo 110 Burner Components 1 3 10 11 12 8 9 2 7 13 5 4 6 Item Part Description 1 EXARKIT04 B...

Страница 33: ...the blower and inlet adaptor Failure to ensure correct fitting may result in serious injury or death EXALT Solo Combi 155 Burner Components 1 8 3 11 12 13 2 5 10 4 7 6 9 6 Item Part Description 1 EXA...

Страница 34: ...the blower and inlet adaptor Failure to ensure correct fitting may result in serious injury or death EXALT Combi 199 Burner Components 7 5 3 6 4 2 9 13 11 12 10 8 1 Item Part Description 1 EXARKIT05...

Страница 35: ...ontrol Module 2 EXARKIT86 Control Box Hinges 3 EXARKIT53 Display Module 4 EXARKIT55 Control Enclosure EXALT Control Display Enclosures 1 2 3 4 Item Part Description 1 EXARKIT52 Control Module 2 EXARKI...

Страница 36: ...ARKIT66 DHW Inlet Fitting 8 EXARKIT67 CH Return Fitting 9 EXARKIT56 Domestic Water Temperature Sensor EXALT Combi Hydro block 1 3 6 2 5 8 7 4 9 Item Part Description 1 EXARKIT60 Hydroblock 2 EXARKIT61...

Страница 37: ...Selection Expertise Solutions We ve Got It IDWB0l PDF 4 21 IDWB0l PDF 4 21 2021 41 Exalt Quick Reference Piping and Wiring Guide...

Отзывы: