IDEAL Europa 224 Скачать руководство пользователя страница 2

europa

europa 224

G.C. appliance No. 47---348---26A

europa 228

G.C. appliance No. 47---348---27A

europa 232

G.C. appliance No. 47---348---28A

Destination countries: GB, IE

INTRODUCTION

europa

are

wall mounted, room sealed, non condensing

boilers featuring full sequence automatic spark ignition and

fan assisted combustion.

europa 224

,

europa 228

and

europa 232

are low water

content

combination gas boilers.

SAFETY

Current Gas Safety (Installation & Use)

Regulations or rules in force

In your own interest, and that of safety, it is the law that this boiler

must be installed by CORGI registered installer or in IE a

competent person, in accordance with the above regulations.
It is essential that the instructions in this booklet are strictly

followed, for safe and economical operation of the boiler.

ELECTRICITY SUPPLY

The appliance must be efficiently earthed.

Supply 230 V 50 Hz. The fusing should be 3 A.
Connection must be made in a way that allows complete

isolation of the electrical supply, such as a double pole switch,

having a 3 mm (1/8”) contact separation in both poles, or a plug

and socket serving only the boiler and system controls. The

means of isolation must be accessible to the user after

installation.

IMPORTANT NOTES

F

This appliance must not be operated without the casing

correctly fitted and forming an adequate seal.

F

If the boiler is installed in a compartment then the

compartment MUST NOT be used for storage purposes.

F

Under no circumstances should any of the sealed

components on this appliance be used incorrectly or

tampered with.

F

If it is known or suspected that a fault exist on the boiler then

it MUST NOT BE USED until the fault has been corrected by

a CORGI registered installer or in IE a competent person.

MINIMUM CLEARANCES

Clearances of 200 mm (7 7/8“) above and below, 25 mm (1“)

at left, 50 mm (2“) at right and 450 mm (17 3/4“) at the front of

the boiler case must be allowed for servicing.

After installation the following clearances are allowable during

use, providing the encasing parts are removeable for

servicing:

The bottom clearance can be reduced to 20mm (3/4”).

The front clearance can be reduced to 50mm (2”).

BOILER CONTROLS

B

C

D

E

F

G

A

A Appliance On lamp
B Domestic hot water temperature control
C Main switch and radiator temperature control
D Boiler reset button
E Lock---out signal lamp
F Programmer
G System pressure and temperature gauge

TO LIGHT THE BOILER

1 Check that the valves located in the lower part of the boiler

are open.

2 Switch the electricity supply on.

The appliance On lamp A will flash every 4 seconds

(stand---by condition).

3 If the boiler is to be used for CH and DHW position the

main switch as in the following illustration.

The appliance On lamp A will flash every 2 seconds

(operating boiler).

C

A

DIAGNOSTIC LIGHTS

The following table gives a summary of the relationship

between each of the possible lamp combinations and their

meaning during normal operaion of the boiler

Normally operating boiler

CH operation

DHW operation

Frost protect operation

Lamp

OFF

Flashing lamp, alone

or simultaneously

with an other lamp.

Flashing lamp,

alternate with

another lamp.

If the lights sequence observed on the boiler is not included

above then a fault is indicated.

reference should be made to the Installation Instructions or

consult a CORGI registered installer.

THE BENCHMARK SERVICE INTERVAL RECORD MUST BE COMPLETED AFTER EACH SERVICE

Caradon Ideal Limited is a member of the Benchmark initiative and fully supports the

aims of the programme. Benchmark has been introduced to improve the standards of

installation and commissioning of central heating systems in the UK and to encourage

the regular servicing of all central heating systems to ensure safety and efficiency.

All CORGI registered installers carry a CORGI ID card, and have a registration number. Both should be recorded in the

Benchmark

Commissioning Checklist. You can check your installer by calling CORGI direct on 01256 372300.

Содержание Europa 224

Страница 1: ......

Страница 2: ...case must be allowed for servicing After installation the following clearances are allowable during use providing the encasing parts are removeable for servicing The bottom clearance can be reduced to 20mm 3 4 The front clearance can be reduced to 50mm 2 BOILER CONTROLS B C D E F G A A Appliance On lamp B Domestic hot water temperature control C Main switch and radiator temperature control D Boile...

Страница 3: ... SHUT DOWN THE BOILER For short periods To turn the boiler off set the function selector C to the O position The appliance On lamp A will flash every 4 seconds For long periods When you do not expect to use the boiler for a long period 1 Switch the electricity supply off 2 Shut off the gas supply cock and the valves for the water circuits fitted under the boiler 3 If necessary empty the water circ...

Страница 4: ... above for the ON setting and confirm by pressing the enter button D Proceed in the same way for other settings Setting example shown in Fig 3 A ON time 7 45 day Monday to Friday B OFF time 10 30 day Monday to Friday A B Fig 3 Activating the timed settings Set the mode selector switch B to the AUTO position shown in Fig 4 The current time and day appears in the display The ON OFF display A indicat...

Страница 5: ...ssing the button E or F and the operation can be forced on or off by pressing the button G The time delay can be set within the following ranges 1 to 23 hours with steps of 1 hour 1 to 27 days with steps of 1 day The time delay setting is activated by moving the switch B to the AUTO position The ON OFF display A flashes indicating that the current state of operation has been forced To delete the t...

Страница 6: ...ition F Check that air pressure switch test caps on top of the boiler are fitted correctly Operating for hot water but will not operate for central heating F Check that integral programmer is set to an on period and the function switch is set to auto If it still does not operate contact your installer F If fitted with an external programmer check that the central heating channel is set at an on pe...

Отзывы: