2

Elise 

Users

Introduction

The

 Elise 

is a wall mounted, room sealed, super efficient

condensing boiler featuring full sequence automatic spark
ignition and fan assisted combustion.

Due to the very high efficiency, condensate is produced from
the flue gases and this is drained to a suitable disposal point
through the plastic waste pipe at the right lower rear of the
boiler.  A condensate 'plume' will also often be visible at the flue
terminal.

S a f e t y

Current Gas Safety (Installation & Use)
Regulations or rules in force.

In your own interest, and that of safety, it is the law that this boiler
must be installed by a Registered Gas Installer.
In IE the installation must be carried out by a competent person
and installed in accordance with the current edition of I.S. 813
“domestic Gas Installations”, the current Building Regulations
and reference should be made to the current ETCI rules for
electrical installation.

It is essential that the instructions in this booklet are strictly
followed, for safe and economical operation of the boiler.

Electricity Supply

The appliance must be earthed.

Supply 230 V - 50 Hz.    The fusing should be 3A.

This appliance is intended to be connected to the supply via a
double-pole switch, having a 3mm contact separation in both
poles, serving only the boiler and system controls. Alternatively,
a 3-pin UNSWITCHED socket may be used.

Important Notes

z

This appliance must not be operated without
the casing correctly fitted and forming an adequate seal.

z

If the boiler is installed in a compartment then the compartment
MUST NOT be used for storage purposes.

z

Under NO circumstances should any of the sealed components
on this appliance be used incorrectly or tampered with.

z

If it is known or suspected that a fault exists on the boiler
then it MUST NOT BE USED until the fault has been
corrected by a Registered Gas Installer or in IE a competent
person.

z

This appliance is not intended for use by persons (including
chilcren) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless
they have been given supervision or instructions concerning
use of the appliance by a person responsible for their safety.

Destination Countries: GB, IE

Elise H15, H24

(Natural Gas Only)

H15

G.C. Appliance No.  41 399 97

H24

G.C. Appliance No.  41 399 98

z

Children should be supervised to ensure that they do not
play with the appliance.

In cases of repeated or continuous shutdown a Registered Gas
Installer or in IE a competent person should be called to
investigate and rectify the condition causing this and carry out an
operational test after each intervention on the device. Only the
manufacturers original parts should be used for replacement.

Minimum Clearances

Clearances of 

165mm (6 1/2"

) above, 

100mm (4"

) below, 

5mm

(1/4"

) at the sides and 

450mm (17 3/4

") at the front of the boiler

casing must be allowed for servicing.
The minimum front and bottom clearance allowed when built
into a cupboard is 5mm.

To light the boiler  

(Refer to Frame 1)

1.

CHECK THAT THE ELECTRICITY SUPPLY TO THE BOILER
IS OFF.

2.

Set the mains on/off switch (A) to off and the CH thermostat
knob (C) to maximum.

3.

Switch on the electricity supply to the boiler and check that all
external controls, e.g. programmer, room thermostat, etc are
on.

4.

Set the mains on/off switch to ON.

The boiler will commence the ignition sequence, supplying heat
to the system when required.

Operation

In normal operation the control unit display (F) will show the
codes:

O - Standby 

  (no demand for heat)

C - CH or DHW being supplied.

During 

ignition

 the LED (E) will flash.

During 

normal running

 the LED will remain illuminated.

Note. 

If the boiler fails to light after 3 attempts the fault code 'L' 'F'

will be displayed.

Press and hold the reset button for 2 seconds then release.
The boiler will repeat the ignition sequence.  If the boiler fails to
light consult a Registered Gas Installer or in IE a competent
person.

All CORGI registered installers carry a CORGI ID card, and have a registration number. Both should be recorded
in the 

Benchmark 

Commissioning Checklist.  You can check your installer by calling CORGI direct on 01256 372300.

THE BENCHMARK SERVICE INTERVAL RECORD MUST BE COMPLETED AFTER EACH SERVICE

Ideal Stelrad Group

 is a member of the Benchmark scheme and fully supports the aims of

the programme.  Benchmark has been introduced to improve the standards of installation and
commissioning of central heating systems in the UK and to encourage the regular servicing of
all central heating systems to ensure safety and efficiency.

Содержание Elise H15

Страница 1: ...his appliance use only spare parts that you can be assured conform to the safety and performance specification that we require Do not use reconditioned or copy parts that have not been clearly authorised by Ideal Boilers H15 H24 For installation guide see reverse of book ...

Страница 2: ...for their safety Destination Countries GB IE Elise H15 H24 Natural Gas Only H15 G C Appliance No 41 399 97 H24 G C Appliance No 41 399 98 z Children should be supervised to ensure that they do not play with the appliance In cases of repeated or continuous shutdown a Registered Gas Installer or in IE a competent person should be called to investigate and rectify the condition causing this and carry...

Страница 3: ... off the boiler and consult a Registered Gas Installer or in IE a competent person Flame failure Should this occur a fault code L F will be displayed Press the reset button and the boiler will relight If the fault recurs turn off the boiler and consult a Registered Gas Installer or in IE a competent person Condensate Drain The condensate drain must not be modified or blocked Blockage of the conden...

Страница 4: ...ral heating or domestic hot water Test by overriding the programmer by setting to continuous Check room thermostat for central heating or the cylinder thermostat for domestic hot water are set at the required temperature To test operation of either thermostat turn fully up If no response contact your installer Boiler is not working for central heating or hot water and the display shows L A L A L A...

Отзывы: