32
Concord ESi
- Installation and Servicing
INSTALLATION
47
GAS CONNECTIONS
Gas connections can be carried out either on the left-hand
side or on the right-hand side of the boiler.
Gas connections shall be in compliance with applicable
regulations and standards.
45
DISPLAY FEATURES
46
TECHNICAL CHARACTERISTICS - SENSORS
Value of water sensors (boiler and domestic hot water)
Thermostat
Temperature
Resistance
Thermostat
Temperature
Resistance
Knob setting
in
o
C
in ohm
Knob setting
in
o
C
in ohm
5
50
3,661
1
10
19,691
6
60
2,535
2
20
12,474
7
70
1,794
3
30
8,080
8
80
1,290
4
40
5,372
9
90
941
In all cases a shut-off valve shall be located as close to the
boiler as possible.
MESSAGES - ALARMS
The display may show the following messages in the case of a malfunction:
Notes
Probable Cause
The corresponding
sensor circuit is
interrupted or is short
circuited
If the power supply is interrupted with
an
alarm and no corrective action
is taken then, when the power is
resumed, the boiler will restart but
continue to operate in a C
H mode only
and alarm
will NOT be displayed.
The calorifier is
empty or incorrectly
fitted AD212 kit
connector
The DHW may be reactivated for 24 hours
by disconnecting and reconnecting the
power supply to the boiler.
Check that the connector supplied in
the AD 212 kit (DHW Sensor), which
has a 22k Ohm resistance and a
100nF capacitor fitted, is correctly
connected to terminals 25 and 26.
Component
Failure
Message
Installation stops Boiler
sensor
Remedy
Inform the
installer
Installation
continues to
operate but DHW
no longer heated
DHW
sensor
No DHW
AD212 kit
connector
Fill the calorifier
or check
connector is
properly fitted.
Check that there
is no short circuit
or the
connections are
made correctly
INST
ALLA
TION