5

3

φ

KVAR KVA Button

• The 3

φ

KVAR KVA button toggles between the KVAR/KVA

measurements and the PF/kW measurements in the 3

φ

3W

or 3

φ

4W functions.

• Toggling between these measurements can only be done

after the power clamp has calculated the power factor and
kW measurement.

Read Next Button

In 3

φ

3W Function

• Pressing the read next button stores the measured values

for kW

RS(L1L2)

/kVA

RS(L1L2)

and moves to the next measurement.

• Pressing read next after the kW

TS(L2L3)

/kVAR

TS(L2L3)

stores the

values and calculates the kW and PF values for the 3

φ

3W

system.

• After these values have been calculated, press the 3

φ

KVAR

KVA button to display the KVAR and KVA values for the sys-
tem.

• To start another calculation, press the read next button again

to return and take a measurement for the kW

RS(L1L2)

/kVARS

(L1L2)

values.

In 3

φ

4W Function

• Pressing the read next button stores the measured values

for W

R(L1)

/PF

R(L1)

and moves to the next measurement.

• Pressing read next after the W

S(L2)

/PF

S(L2)

stores the values

and moves on to the next measurement.

• Pressing read next after the W

T(L3)

/PF

T(L3)

stores the values

and calculates the kW and PF values for the 3

φ

4W system.

• After these values have been calculated, press the 3

φ

KVAR

KVA button to display the KVAR and KVA values for the sys-
tem.

• To start another calculation, press the read next button again

to return and take a measurement for the W

R(L1)

/PF

R(L1)

values.

6

In any other function
• Pressing the read next button in any other function displays

the measurement values stored with the REC button.

• The REC NO. symbol will be shown on the LCD display and

the record number will flash on the secondary display to noti-
fy the user of what values are being displayed.

• Pressing this button after the meter displays last stored data

point returns to the first stored data point.

• To exit the read next mode, turn the function switch to any

other function.  This will exit without losing the stored data.

Kilowatt/Power Factor Measurements

Kilowatt Range

Resolution Accuracy

Voltage/Current 

(AC+DC True Power) 

Range

0-99.99kW 0.01kW 

±(2.0% 

+0.05) 600VAC, 

800VDC

100-999.9kW 

0.1kW

2000A AC/DC  

1000-1600kW 1kW 

±(2.0% 

+5)

Power Factor 0.2-1.0 for 1

φ

2W, 1

φ

3W, 3

φ

3W, and 3

φ

4W

Autoranging Table

0-200VAC

200-600VAC

0-200VDC

200-800VDC

0-200A 

0.00-40.00kW 0.00-99.99kW

100.0-160.0kW

200-2000A

0.0-400.0kW 0.0-999.9kW

1000-1600kW  

3ØPF
AC+DC
2000KW
2000A

OFF

PFKW

HzV

3Ø3W

3Ø4W

KVARKVA

VA

DC
A/W

ZERO

REC

3

Ø

KVAR
KVA

READ
NEXT

HOLD

CAT III - 600V

Power Clamp

True RMS

61-802

Содержание 800 Series

Страница 1: ...61 802 2 61 802 800 Series Power Clamp Meter 3 PF AC DC 2000KW 2000A OFF PFKW HzV 3 3W 3 4W KVARKVA VA DC A W ZERO REC 3 KVAR KVA READ NEXT HOLD CAT III 600V Power Clamp True RMS 61 802 1 Transformer...

Страница 2: ...fingers behind the finger guards on the probes Work with others 6 Before beginning all unknown measurements set meter to highest possible range 7 Before breaking a circuit for testing turn off the po...

Страница 3: ...4W system After these values have been calculated press the 3 KVAR KVA button to display the KVAR and KVA values for the sys tem To start another calculation press the read next button again to return...

Страница 4: ...PF indicates an inductive load while negative PF indicates a capacitive load 8 To measure Kilowatts and Power Factor in a single phase 3 wire system See section on 1 3W AC DC Power Measurements AC DC...

Страница 5: ...e the trigger and be sure that the jaws have closed completely Insert the black test lead into the COM terminal and the red test lead into the terminal Connect the test probes in parallel with the loa...

Страница 6: ...AC DC Power Measurements 3 3W AC DC Power Measurements Kilowatt Range Resolution Accuracy Voltage Current AC DC True Power Range 0 99 99kW 0 01kW 2 0 0 05 600VAC 800VDC 100 999 9kW 0 1kW 2000A AC DC 1...

Страница 7: ...third phase eg T or L3 Using the trigger to open the jaws fully enclose the phase T or L3 within the clamp Release the trigger and be sure that the jaws have closed completely Wait until the reading...

Страница 8: ...W ZERO but ton once to zero out the watt reading Insert the black test lead into the COM terminal and the red test lead into the terminal 16 L1G Measurement Connect the black test probe to ground and...

Страница 9: ...data from memory and readies the power clamp for another single phase 3 wire calculation 3 4W AC DC Power Measurements Kilowatt Range Voltage Current AC DC True Power Resolution Accuracy Range 0 99 9...

Страница 10: ...ess the READ NEXT button to capture the reading storing the data in memory The LCD display will show a flashing T to indicate that the meter is ready for the next measurement Remove the clamp and test...

Страница 11: ...e used in a 1 2W or 3 4W systems Three phase capacitors are available for 3 3W and 3 4W systems Determining the Required Capacitor Value Measure the kVAR3 3W value of the power system The capacitor va...

Страница 12: ...Lifetime Limited Warranty This meter is warranted to the original purchaser against defects in material or workmanship for the lifetime of the meter During this warranty period IDEAL INDUSTRIES INC wi...

Отзывы: