CLEANING AND STORAGE

1.  The white plastic light sensor should be cleaned with a damp cloth when 

  neccessary.

2.  When the meter is not in use keep the light sensor covered with the light 

  sensor cap.

3.  Remove the battery if the unit is not used for an extended period of time.

4.  Store the meter in an area with moderate temperature and humidity (refer 

  to the operating and storage range in the specifications chart)

RELATIVE SPECTRAL SENSITIVITY

Peak sensitivity wavelength: 550nm     

Typ. Ta=23°

WAVELENTH (nm)

*CIE luminous spectral luminous

αβχδεφγηιϕκ

WARRANTY STATEMENT

This tester is warranted to the original purchaser against defects in material 

and workmanship for two years from the date of purchase. During this warranty 

period, IDEAL INDUSTRIES, INC. will, at its option, replace or repair the defec-

tive unit, subject to verification of the defect or malfunction. 
This warranty does not cover fuses, batteries or damage from abuse, neglect, 

accident, unauthorized repair, alteration, or unreasonable use of the instrument.
Any implied warranties arising out of the sale of an IDEAL product, including 

but not limited to implied warranties of merchantability and fitness for a par-

ticular purpose, are limited to the above. The manufacturer shall not be liable 

for loss of use of the instrument or other incidental or consequential damages, 

expenses, or economic loss, or for any claim or claims for such damage, 

expenses or economic loss.
State laws vary, so the above limitations or exclusions may not apply to you. 

This warranty gives you specific legal rights, and you may also have other 

rights which vary from state to state.

 

Содержание 61-686

Страница 1: ...ns while measuring Do not operate the meter in an environment with explosive gas combustible gas steam or an area filled with dust If erratic operation occurs please replace the battery immediately In...

Страница 2: ...ination the inside surface an imaginary 1 foot radius sphere would be receiving if there were a uniform point source of one candela in the exact center of the sphere Alterna tively it can be defined a...

Страница 3: ...ement is out of range an OL will appear in the display Press the MANU button to change the range 5 To save the current value on the LCD press the Data Hold button Press the Data Hold button again to r...

Страница 4: ...h battery Accessories User s manual carrying case 9V battery Length of cable for light sensor Approx 59 in 1 5M Operating Environment Indoor use only This instrument has been designed for use in an en...

Страница 5: ...arranty period IDEAL INDUSTRIES INC will at its option replace or repair the defec tive unit subject to verification of the defect or malfunction This warranty does not cover fuses batteries or damage...

Страница 6: ...nto en un ambiente con gas explosivo vapor de gas combustible o lleno de polvo Si el funcionamiento es err tico reemplace la bater a inmediatamente A fin de evitar da os causados por contaminaci n o e...

Страница 7: ...fera imaginaria de 1 pie de radio si hubiera una fuente puntual uniforme de una buj a en el centro exacto de dicha esfera Como alternativa se puede definir como la iluminancia de una superficie de 1 p...

Страница 8: ...mente 5 minutos se apaga autom ticamente PUESTA A CERO DEL INSTRUMENTO Encienda el instrumento con la tapa del sensor de luz colocada Debe leerse 000 en todos los rangos Si el instrumento no indica 00...

Страница 9: ...aparece en la pantalla el s mbolo de la bater a Reemplace la bater a de 9 V retirando la tapa del com partimiento de la bater a y accediendo al mismo Observe la polaridad cuando reemplaza la bater a...

Страница 10: ...raciones no autorizadas alteraciones o uso no razonable del instrumento Todas las garant as impl citas originadas en la venta de un producto IDEAL incluidas pero sin limitarse a ellas las garant as im...

Страница 11: ...nner l appareil en pr sence de gaz explosif de vapeur de gaz combustible ou dans un lieu envahi de poussi re en suspension dans l air En cas de fonctionnement erratique remplacer imm diatement la pile...

Страница 12: ...pied bougie est d fini comme tant la quantit d illumination que recevrait la surface d une sph re d un rayon de 1 pied 30 cm s il existait un point source uniforme d une chandelle au centre pr cis de...

Страница 13: ...e de plage et en dehors de la plage de mesure OL sera affich Appuyer sur MANU pour changer de plage 5 Pour sauvegarder la valeur actuelle sur l affichage cristaux liquides appuyer sur le bouton de mai...

Страница 14: ...x 2 2 P x 3 1 L po 25 H x 55 P x 80 L mm Poids Environ 250 g 8 9 oz avec la pile Accessoires Manuel de l utilisateur sac de transport pile de 9 V Longueur de c ble du capteur optique Environ 1 5 m 59...

Страница 15: ...ettoy avec un chiffon humide s il y a lieu 2 Quand le luxm tre n est pas en service il faut maintenir le capteur optique recouvert par son capuchon 3 Retirer la pile si l on ne doit pas utiliser l app...

Страница 16: ...n gligence d un accident d une r paration non autoris e d une modification ou d une utilisation d raison nable de l instrument Toutes les garanties implicites r sultant de la vente d un produit IDEAL...

Отзывы: